摘要
The subject building is a peculiar pre-Northridge steel moment resisting frame building. Upon investigating the existing lateral resisting system, numerous significant deficiencies were identified; inherent lack of redundancy, poor geometry and inadequate stiffness of the lateral resisting system. All of which resulted in an extremely soft 5-story structure with a primary torsional mode of vibration at T(1)=5.46s. Significant structural modifications were deemed necessary to meet the "life-safety" performance objective as outlined in rehabilitation standards such as ASCE 41. Both increased stiffness and damping were required to adequately retrofit the building. Furthermore, adjacent building separation as well as deformation compatibility issues needed to be addressed and resolved. A three-dimensional computer model of the building was created using ETABS mathematically simulating the building's dynamic characteristics in its current condition. Multiple seismic retrofit systems were investigated such as Buckling Restrained Braced Frames (BRBF's). However, based on the performance effectiveness and constructability of the retrofit schemes studied, the Viscous-Fluid-Spring Damper (VFSD) system was proposed as the "optimum" solution for the building. The VFSD, was chosen because it combines the relatively compact size and minimally invasive constructability with the required properties (an elastomeric spring in parallel with a nonlinear velocity dependent viscous damper). A site-specific response spectrum was developed for the Design Basis Earthquake (DBE, 475 year return period) event, and three pairs of representative earthquake horizontal ground motion time-histories were scaled to match this DBE. The proposed scheme reduced the building maximum inter-story drift ratio from 5.4% to about 1%. Similarly, the maximum roof displacement was reduced by about 70% (23" to 7").
引用
收藏
页码:1381 / 1389
页数:9
相关论文
共 50 条
  • [1] Seismic Retrofit of a High-Rise Steel Moment Resisting Frame Using Fluid Viscous Dampers
    Wang, Shanshan
    Lai, Jiun-Wei
    Schoettler, Matthew J.
    Mahin, Stephen A.
    IMPROVING THE SEISMIC PERFORMANCE OF EXISTING BUILDINGS AND OTHER STRUCTURES 2015, 2015, : 121 - 131
  • [2] Seismic retrofit of a high-rise steel moment-resisting frame using fluid viscous dampers
    Wang, Shanshan
    Mahin, Stephen A.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (10):
  • [3] Performance-based seismic design of a spring-friction damper retrofit system installed in a steel frame
    Gharagoz, Masoum M.
    Chun, Seungho
    Noureldin, Mohamed
    Kim, Jinkoo
    STEEL AND COMPOSITE STRUCTURES, 2024, 51 (02): : 173 - 183
  • [4] Seismic Retrofit of an Existing Steel Arch Bridge Using Viscous Damper
    Kandemir, E. C.
    Mazda, T.
    Nurui, H.
    Miyamoto, H.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [5] Seismic performance enhancement of steel moment frame structures using fluid viscous dampers
    Gilani, A.
    Miyamoto, K.
    STESSA 2006, 2006, : 691 - 696
  • [6] Fluid Viscous Damper-Based Seismic Retrofit Strategies of Steel Structures: General Concepts and Design Applications
    Sorace, Stefano
    Terenzi, Gloria
    ADVANCED STEEL CONSTRUCTION, 2009, 5 (03): : 325 - 342
  • [7] Retrofit of pre-Northridge steel moment-resisting frames using fluid viscous dampers
    Uriz, P
    Whittaker, AS
    STRUCTURAL DESIGN OF TALL BUILDINGS, 2001, 10 (05): : 371 - 390
  • [8] Seismic performance of moment resistant steel frame with hysteretic damper
    Huang, YH
    Wada, A
    Sugihara, H
    Narikawa, M
    Takeuchi, T
    Iwata, M
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 403 - 409
  • [9] Base isolation as a retrofit strategy for welded steel moment frame buildings
    Kim, S
    D'Amore, E
    FOURTH CONFERENCE ON TALL BUILDINGS IN SEISMIC REGIONS, PROCEEDINGS: TALL BUILDINGS FOR THE 21ST CENTURY, 1997, : 521 - 534
  • [10] An Experimental and Numerical Investigation on Seismic Retrofit of Steel Moment Frame Connections
    Bahirai, Mohammad
    Gerami, Mohsen
    JOURNAL OF EARTHQUAKE ENGINEERING, 2021, 25 (10) : 2085 - 2105