Research on Non-contact Angle Measurement Based on AMR Effect

被引:1
|
作者
Huang, Yinguo [1 ]
Zhuang, Shuya [1 ]
Wang, Zhiyi [1 ]
Zhang, Xiaomei [1 ]
Zhao, Meirong [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin, Peoples R China
关键词
Angle measurement; Non-contact; AMR; Wheatstone bridge;
D O I
10.1007/978-981-10-6571-2_245
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A non-contact angle measuring method based on AMR effect is proposed in this paper. The method improves the measurement sensitivity and resolution with a Wheatstone bridge. In this paper, the function of the output voltage of the Wheatstone bridge is derived, which is on the angle between the direction of the external magnetic field and the bridge. Besides, the magnetic field distribution of a radially magnetized permanent magnet is analyzed. A device for measuring the angle in the range of +/- 10 degrees is designed, and the sensitivity of the device is about 15 mV/arcminute. The method introduced in this paper has advantages of simple structure, low cost, high sensitivity and free from space limitation.
引用
收藏
页码:2013 / 2019
页数:7
相关论文
共 50 条
  • [1] Non-Contact Measurement Method Research Based on HoloLens
    Huang Jing
    Yang Boxiong
    Chen Jiajie
    2017 INTERNATIONAL CONFERENCE ON VIRTUAL REALITY AND VISUALIZATION (ICVRV 2017), 2017, : 267 - 271
  • [2] Research on Synchronous Measurement Methods Based on Non-Contact Sensing
    Wang, Tianyu
    Liu, Hao
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 414 - 419
  • [3] Research on Screw Thread Form Based on Non-Contact Measurement
    Shen, Shaofeng
    Wang, Xiancheng
    Chen, Junhua
    ADVANCES IN ENGINEERING DESIGN AND OPTIMIZATION II, PTS 1 AND 2, 2012, 102-102 : 593 - +
  • [4] Non-contact Measurement of Rotation Angle with Solo Camera
    Gan Xiaochuan
    Sun Anbin
    Ye Xin
    Ma Liqun
    NINTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2015, 9446
  • [5] Non-contact angle measurement based on parallel multiplex laser feedback interferometry
    张松
    谈宜东
    张书练
    Chinese Physics B, 2014, (11) : 324 - 328
  • [6] Non-contact measurement for cone angle of axicon lens based on vortex interference
    Xiao, Mucang
    Yang, Dong
    Xiong, Jianwen
    OPTICS COMMUNICATIONS, 2021, 499
  • [7] Research of non-contact stiffness measurement technology
    Liu, Wenxuan
    Wang, Huifeng
    Wang, Guanglin
    Shao, Dongxiang
    Key Engineering Materials, 2014, 621 : 331 - 336
  • [8] Non-contact angle measurement based on parallel multiplex laser feedback interferometry
    Zhang Song
    Tan Yi-Dong
    Zhang Shu-Lian
    CHINESE PHYSICS B, 2014, 23 (11)
  • [9] Research on signal denoise in non-contact measurement based on conoscopic holography
    Ren, Shu-Yan
    Zhang, Zhuo
    Liu, Guo-Dong
    Pu, Zhao-Bang
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2008, 19 (06): : 790 - 794
  • [10] Non-contact rotation angle measurement system for scanning mirrors
    Wang, Yang
    Yan, Chang-Xiang
    Hu, Chun-Hui
    Wang, Yi-Qun
    Gu, Zhi-Yuan
    Zhang, Da
    Zhang, Xin-Jie
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2014, 22 (04): : 850 - 855