Measurements and Evaluation of Proximal Femoral Bone Mineral Density with Dual Energy X-ray Absorptiometry

被引:0
|
作者
Hayashida, Keiichi [1 ,2 ]
Takeda, Yoshihiro [2 ]
Katsuda, Toshizo
Yamamoto, Kenyu [3 ]
Suesada, Yasuhide [1 ]
Shibata, Moeko [1 ]
Azuma, Masami [4 ]
机构
[1] Meiwa Hosp, Dept Radiol, Nishinomiya, Hyogo 6638186, Japan
[2] Okayama Univ, Grad Sch Hlth Sci, Dept Radiol Technol, Okayama 7008550, Japan
[3] Osaka Canc Prevent & Detect Ctr, Osaka 5368588, Japan
[4] Osaka Kyoiku Univ, Osaka 5828582, Japan
关键词
proximal femoral BMD; dual energy X-ray absorptiometry; Ward's BMD; Ward's cognitive method; HIP FRACTURE; OSTEOPOROSIS; WOMEN; TOTTORI; JAPAN; FEMUR; SPINE; AGE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Proximal femoral bone mineral density (BMD) can be measured by dual energy X-ray absorptiometry method in the neck, trochanter, intertrochanter, total and Ward's triangle area. Ward's triangle area of the proximal femur is a smaller area to measure than the others, and the position varies, depending on the status of inner rotation of the target leg. In this study, the measurements of the proximal femoral BMD in women were carried out on the neck, trochanter, intertrochanter, total and Ward's triangle area with the, subjects' legs turned 15 degrees toward the inside. The Ward's BMD were measured using Ward's cognitive method, in which the measured BMD were compared among age groups of 50-59, 60-69, 70-79 and 80-89 to determine whether this process could reveal decreased femoral BMD in elderly women. The correlation between BMD and age was tested using the Pearson correlation coefficient. In all measured parts, the BMD of women age 50-59 were significantly higher than those of women age 80-89. The correlations between BMD and age were negative in all measured parts, and the most negative correlation was between age and Ward's BMD. The study using Ward's cognitive method showed an inverse correlation between Ward's BMD and age in women.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [1] Measurements and Evaluation of Proximal Femoral Bone Mineral Density with Dual Energy X-ray Absorptiometry
    Hayashida, K.
    Katsuda, T.
    Yamamoto, K.
    Takeda, Y.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 703 - +
  • [2] Bone mineral density and width of the femoral shaft by dual energy X-ray absorptiometry
    Kolta, S
    Fechtenbaum, J
    Listrat, V
    Dougados, M
    Roux, C
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : S581 - S581
  • [3] EFFECT OF FEMORAL ROTATION ON BONE-MINERAL DENSITY-MEASUREMENTS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOH, JCH
    LOW, SL
    BOSE, K
    CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) : 340 - 343
  • [4] Dual energy x-ray absorptiometry measurements of bone mineral density of the proximal tibia following total knee arthroplasty
    Albanese, C
    Preite, R
    Kvasnova, M
    DiGirolamo, M
    Pirillo, S
    Passariello, R
    RADIOLOGY, 1997, 205 : 425 - 425
  • [5] Evaluation of bone mineral density in CAPD patients with dual energy x-ray absorptiometry
    Pasadakis, P
    Thodis, E
    Mourvati, E
    Euthimiadou, A
    Margaritis, D
    Manavis, J
    Vargemezis, V
    ADVANCES IN PERITONEAL DIALYSIS/1996, VOL 12, 1996, 12 : 245 - 249
  • [6] Hazards with evaluation of bone mineral density by dual-energy x-ray absorptiometry
    Bolosiu, CR
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S127 - S127
  • [7] Retrospective evaluation and adjustment of dual energy X-ray absorptiometry measurements for bone mineral density research studies
    Fang, ZX
    Smith, JA
    Kleppinger, A
    Reisine, ST
    Emerson, D
    Kulldorff, M
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (04) : 421 - 433
  • [8] The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals
    Joel T Fuller
    Jane Archer
    Jonathan D Buckley
    Margarita D Tsiros
    Dominic Thewlis
    Skeletal Radiology, 2016, 45 : 135 - 140
  • [9] Bone mineral density measurements in otosclerosis using dual-energy X-ray absorptiometry
    Tonuk, S. B.
    Koybasi, S.
    Bicer, Y. O.
    Alkan Temel, S.
    CLINICAL OTOLARYNGOLOGY, 2016, 41 (02) : 149 - 153
  • [10] The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals
    Fuller, Joel T.
    Archer, Jane
    Buckley, Jonathan D.
    Tsiros, Margarita D.
    Thewlis, Dominic
    SKELETAL RADIOLOGY, 2016, 45 (01) : 135 - 140