Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

被引:2
|
作者
Neupane, S. [1 ]
Heideman, J. [1 ]
Grzywacz, R. [1 ,3 ]
Hooker, J. [1 ]
Jones, K. L. [1 ]
Kitamura, N. [1 ]
Thornsberry, C. R. [1 ]
Heilbronn, L. H. [2 ]
Rajabali, M. M. [4 ]
Alberty-Jones, Y. [5 ]
Derkin, J. [5 ]
Massey, T. N. [5 ]
Soltesz, D. [5 ]
机构
[1] Univ Tennessee, Dept Phys & Astron, Knoxville, TN 37996 USA
[2] Univ Tennessee, Dept Nucl Engn, Knoxville, TN 37996 USA
[3] Oak Ridge Natl Lab, Phys Div, POB 2009, Oak Ridge, TN 37831 USA
[4] Tennessee Technol Univ, Dept Phys, Cookeville, TN 38505 USA
[5] Ohio Univ, Dept Phys & Astron, Athens, OH 45701 USA
基金
美国国家科学基金会;
关键词
Neutron emission; Neutron detection; Efficiency;
D O I
10.1016/j.nima.2021.165881
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where fl-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure fl-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. The first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] NEUTRON DETECTION EFFICIENCY OF A THICK LITHIUM GLASS DETECTOR
    KONONOV, VN
    POLETAEV, ED
    BOHOVKO, MV
    KAZAKOV, LE
    TIMOHOV, VM
    DYACHENKO, PP
    KUTSAEVA, LS
    SEREGINA, EA
    LAJTAI, A
    KECSKEMETI, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 234 (02): : 361 - 366
  • [2] Detection efficiency of a new type of solar neutron detector calibrated by an accelerator neutron beam
    Tsuchiya, H
    Muraki, Y
    Masuda, K
    Matsubara, Y
    Koi, T
    Sako, T
    Ohno, S
    Hoshida, T
    Shibata, S
    Munakata, Y
    Hatanaka, K
    Wakasa, T
    Sakai, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2): : 183 - 193
  • [3] Microstructure Boron Detector for High Efficiency Thermal Neutron Detection
    Fujiwara, T.
    Takahashi, H.
    Yamada, N. L.
    Uesaka, M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [4] DETECTION EFFICIENCY OF THE NEUTRON MODULAR DETECTOR DEMON AND RELATED CHARACTERISTICS
    TILQUIN, I
    ELMASRI, Y
    PARLOG, M
    COLLON, P
    HADRI, M
    KEUTGEN, T
    LEHMANN, J
    LELEUX, P
    LIPNIK, P
    NINANE, A
    HANAPPE, F
    BIZARD, G
    DURAND, D
    MOSRIN, P
    PETER, J
    REGIMBART, R
    TAMAIN, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (2-3): : 446 - 461
  • [5] High efficiency neutron detector for low neutron flux measurement
    Waheed A.
    Aqil-Ur-Rahman
    Zakaullah M.
    Murtaza G.
    Journal of Fusion Energy, 2000, 19 (1) : 91 - 92
  • [6] High efficiency neutron detector for low neutron flux measurement
    Waheed, A
    Aqil-ur-Rahman
    Zakaullah, M
    Murtaza, G
    JOURNAL OF FUSION ENERGY, 2000, 19 (01) : 91 - 92
  • [7] SIMULTANEOUS MEASUREMENT OF NEUTRON-FLUX AND NEUTRON DETECTOR EFFICIENCY
    DUPONT, C
    LELEUX, P
    LIPNIK, P
    SINDANO, WK
    WAUTERS, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (02): : 339 - 341
  • [8] High detection efficiency ZnS scintillator for a fibercoded linear neutron detector for thermal neutron scattering instruments
    Nakamura, T.
    Schooneveld, E. A.
    Rhodes, N. J.
    Katagiri, A.
    Tsutsui, N.
    Toh, K.
    Sakasai, K.
    Soyama, K.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 490 - +
  • [9] EFFICIENCY MEASUREMENTS OF A LARGE NEUTRON DETECTOR
    GOULDING, CA
    GREENFIELD, MB
    BAINUM, DE
    RAPAPORT, J
    FOSTER, CC
    WARD, TE
    ZAFIRATOS, CD
    SCHERY, SD
    GOODMAN, CD
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (04): : 558 - 558
  • [10] A HIGH-EFFICIENCY NEUTRON DETECTOR
    DUCKWORTH, JC
    MERRISON, AW
    WHITTAKER, A
    NATURE, 1950, 165 (4185) : 69 - 69