Middle cerebral artery to umbilical artery resistance index ratio in the prediction of neonatal outcome

被引:53
|
作者
Makhseed, M [1 ]
Jirous, J
Ahmed, MA
Viswanathan, DL
机构
[1] Matern Hosp, Safat, Kuwait
[2] Kuwait Univ, Fac Med, Dept Obstet & Gynecol, Safat, Kuwait
[3] Kuwait Univ, Fac Med, Dept Pediat, Safat, Kuwait
关键词
middle cerebral artery; umbilical artery; C/U ratio; neonatal outcome; brain-sparing;
D O I
10.1016/S0020-7292(00)00262-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The objectives of this study were to evaluate the usefulness of the middle cerebral artery to umbilical artery resistance index ratio (C/U ratio) as a predictor of adverse perinatal outcome, and to show that the absence of fetal umbilical artery end-diastolic velocity (AEDV) in SGA fetuses is associated with high morbidity and mortality. Method: In this prospective study, color Doppler flow imaging was used for the estimation of the C/U ratio in fetuses that were small for their gestational age, in 70 singleton pregnancies between 29 and 42 weeks of gestation. The subjects were categorized into two groups, with Group A consisting of 35 small for gestational age (SGA) fetuses with a normal C/U ratio (1.05 or higher), and Group B comprising 35 SGA fetuses with an abnormal C/U ratio (below 1.05). Result: The mean C/U ratio values for birth weight and gestational age were higher in group A than in group B. Fetuses born to mothers in group B stayed longer in the neonatal special care unit (NSCU), whereas the period from ultrasound examination to delivery was higher in the cases in group A. A higher percentage of mothers with an abnormal C/U ratio underwent cesarean section. Fetuses with an absent end-diastolic velocity of the umbilical artery had a higher morbidity. Three stillbirths occurred in fetuses with an absent end-diastolic velocity of the umbilical artery. Conclusion: Our results suggest that the C/U ratio is a good predictor of neonatal outcome, and could be used to identify fetuses at risk of morbidity and mortality. Fetal umbilical artery AEDV with intrauterine growth restriction is associated with high perinatal morbidity and mortality. (C) 2000 International Federation of Gynecology and Obstetrics. All rights reserved.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [1] ACCURACY OF THE MIDDLE-CEREBRAL-TO-UMBILICAL-ARTERY RESISTANCE INDEX RATIO IN THE PREDICTION OF NEONATAL OUTCOME IN PATIENTS AT HIGH-RISK FOR FETAL AND NEONATAL COMPLICATIONS
    ARIAS, F
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (06) : 1541 - 1545
  • [2] Prediction of perinatal outcome in preeclampsia using middle cerebral artery and umbilical artery pulsatility and resistance indices
    Rani, Shikha
    Huria, Anju
    Kaur, Ravinder
    HYPERTENSION IN PREGNANCY, 2016, 35 (02) : 210 - 216
  • [3] Predictive value of middle cerebral artery to umbilical artery pulsatility index ratio for neonatal outcomes in hypertensive disorders of pregnancy
    Zarean, Elahe
    Azami, Nahal
    Shahshahan, Zahra
    ADVANCED BIOMEDICAL RESEARCH, 2022, 11 (01): : 46
  • [4] Middle cerebral/umbilical artery resistance index ratio as sensitive parameter for fetal well-being and neonatal outcome in patients with preeclampsia: Case-control study
    Ebrashy, A
    Azmy, O
    Ibrahim, M
    Waly, M
    Edris, A
    CROATIAN MEDICAL JOURNAL, 2005, 46 (05) : 821 - 825
  • [5] Ratio of middle cerebral to umbilical artery blood velocity in preeclamptic & hypertensive women in the prediction of poor perinatal outcome
    Yalti, S
    Oral, Ö
    Gürbüz, B
    Özden, S
    Atar, F
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2004, 120 (01) : 44 - 50
  • [6] Fetal Middle Cerebral Artery and Umbilical Artery Pulsatility Index Doppler Associations With Pregnancy Risk and Neonatal Outcomes
    Setiawan, Dani
    Mose, Johanes Cornelius
    Azis, Muhammad Alamsyah
    INTERNATIONAL JOURNAL OF CHILDBIRTH, 2023, 13 (02) : 97 - 107
  • [7] Fetal Medicine Foundation reference ranges for umbilical artery and middle cerebral artery pulsatility index and cerebroplacental ratio
    Ciobanu, A.
    Wright, A.
    Syngelaki, A.
    Wright, D.
    Akolekar, R.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (04) : 465 - 472
  • [8] Cerebral/umbilical artery ratio as predictor of adverse perinatal outcome
    Palermo, M.
    Aguilar, M.
    Luscialdo, S.
    Trillo, S.
    Monaco, A.
    Goldman, A.
    Ultrasound in Medicine and Biology, 1997, 23 (Suppl 1):
  • [9] Umbilical Artery and Middle Cerebral Artery and Cerebroplacental Ratio for Doppler Indices' Reference Ranges
    Sultana, A. R. J. U. A. M. N. D.
    Anjum, Muhammad Nawaz
    Asad, N. A. V. E. E. D.
    UL Haq, R. I. Z. W. A. N.
    Shahid, T. A. I. M. O. O. R.
    Sadaf, Q. U. D. S. I. A.
    Tariq, A. M. I. N. A.
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (07): : 1581 - 1586
  • [10] Reference ranges for umbilical and middle cerebral artery pulsatility index and cerebroplacental ratio in prolonged pregnancies
    Palacio, M
    Figueras, F
    Zamora, L
    Jiménez, JM
    Puerto, B
    Coll, O
    Cararach, V
    Vanrell, JA
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (06) : 647 - 653