Determination of phthalic acid esters in water samples using core-shell poly(dopamine) magnetic nanoparticles and gas chromatography tandem mass spectrometry

被引:31
|
作者
Gonzalez-Salamo, Javier [1 ]
Socas-Rodriguez, Barbara [1 ]
Hernandez-Borges, Javier [1 ]
Angel Rodriguez-Delgado, Miguel [1 ]
机构
[1] ULL, Fac Ciencias, Dept Quim, Unidad Dept Quim Analit, Avda Astrofis Fco Sdnchez S-N, San Cristobal De La Lagu 38206, Spain
关键词
Phthalic acid esters; Water; Magnetic-nanoparticles; Poly(dopamine); Gas chromatography; Tandem mass spectrometry; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; ENVIRONMENTAL WATER; ESTROGENIC COMPOUNDS; HUMAN EXPOSURE; POLYDOPAMINE; LIQUID; SORBENT; PRECONCENTRATION; MICROEXTRACTION;
D O I
10.1016/j.chroma.2017.11.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the first application of core-shell poly(dopamine) magnetic nanoparticles as sorbent for the extraction of a group of eleven phthalic acid esters of interest (i.e. diethyl phthalate (DEP), dipropyl phthalate (DPP), dibutyl phthalate (DBP), bis-isopentyl phthalate (DIPP), bis-n-pentyl phthalate (DNPP), benzylbutyl phthalate (BBP), dicyclohexyl phthalate (DCHP), di-(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), diisononyl phthalate (DINP) and diisodecyl phthalate (DIDP)) and one adipate (bis (2-ethylhexyl) adipate, DEHA) from different water samples (Milli-Q mineral, tap, pond and waste water) is proposed. Analysis were carried out by gas chromatography triple quadrupole tandem mass spectrometry. Parameters that affect the extraction performance were optimized following a step by step approach, being the optimum conditions the extraction of water at pH 6, with 60 mg of sorbent and the elution with 6 mL of dichloromethane. The methodology was validated for the five selected water samples using DBP-d(4) as internal standard. Determination coefficients of matrix-matched calibration curves were above 0.9904 in all cases while relative recovery values ranged between 71 and 120%, with relative standard deviation values below 19%. The limits of quantification of the method ranged between 9 and 20 ng/L. Matrix effects were found for most analytes and water samples. Real water samples were also analyzed, finding DEP and DBP at concentrations below 4.20 and 1.23 mu g/L, respectively, in mineral, tap and waste water. DCHP, DEHP and BBP were also found in some of the samples at concentrations below the LOQs of the method. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [1] Determination of phthalic acid esters in different baby food samples by gas chromatography tandem mass spectrometry
    Bárbara Socas-Rodríguez
    Javier González-Sálamo
    Antonio V. Herrera-Herrera
    Álvaro Santana-Mayor
    Javier Hernández-Borges
    Analytical and Bioanalytical Chemistry, 2018, 410 : 5617 - 5628
  • [2] Determination of phthalic acid esters in different baby food samples by gas chromatography tandem mass spectrometry
    Socas-Rodriguez, Barbara
    Gonzalez-Salamo, Javier
    Herrera-Herrera, Antonio, V
    Santana-Mayor, Alvaro
    Hernandez-Borges, Javier
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (22) : 5617 - 5628
  • [3] Determination of phthalic acid esters in soil by gas chromatography-tandem mass spectrometry
    Li Hong
    Tian Fulin
    Ren Xuedong
    Wang Xinrui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 563 - 566
  • [4] Determination of phthalic acid esters in water samples by hollow fiber liquid-phase microextraction prior to gas chromatography tandem mass spectrometry
    Gonzalez-Salamo, Javier
    Angel Gonzalez-Curbelo, Miguel
    Socas-Rodriguez, Barbara
    Hernandez-Borges, Javier
    Angel Rodriguez-Delgado, Miguel
    CHEMOSPHERE, 2018, 201 : 254 - 261
  • [5] Evaluation of Phthalic Acid Esters in Fish Samples Using Gas Chromatography Tandem Mass Spectrometry with Simplified QuEChERS Technique
    Yanyang Xu
    Rui Weng
    Yushun Lu
    Xinlu Wang
    Dan Zhang
    Yun Li
    Jing Qiu
    Yongzhong Qian
    Food Analytical Methods, 2018, 11 : 3293 - 3303
  • [6] Evaluation of Phthalic Acid Esters in Fish Samples Using Gas Chromatography Tandem Mass Spectrometry with Simplified QuEChERS Technique
    Xu, Yanyang
    Weng, Rui
    Lu, Yushun
    Wang, Xinlu
    Zhang, Dan
    Li, Yun
    Qiu, Jing
    Qian, Yongzhong
    FOOD ANALYTICAL METHODS, 2018, 11 (12) : 3293 - 3303
  • [7] Determination of 23 phthalic acid esters in food by liquid chromatography tandem mass spectrometry
    Xu, Dunming
    Deng, Xiaojun
    Fang, Enhua
    Zheng, Xianghua
    Zhou, Yu
    Lin, Liyi
    Chen, Luping
    Wu, Ming
    Huang, Zhiqiang
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1324 : 49 - 56
  • [8] Magnetic solid-phase extraction using a mixture of two types of nanoparticles followed by gas chromatography-mass spectrometry for the determination of six phthalic acid esters in various water samples
    Li, Hui
    Cao, Zhen
    Cao, Xiaolin
    Jiang, Zejun
    Abd El-Aty, A. M.
    Qi, Yan
    Shao, Hua
    Jin, Fen
    Zheng, Lufei
    Wang, Jing
    RSC ADVANCES, 2018, 8 (69): : 39641 - 39649
  • [9] Magnetic Graphene Dispersive Solid-Phase Extraction for the Determination of Phthalic Acid Esters in Flavoring Essences by Gas Chromatography Tandem Mass Spectrometry
    Zhu, Jing
    Lu, Binglin
    Liu, Shanshan
    Xu, Aifei
    Tang, Guifang
    Chen, Zhiyan
    Pan, Yuling
    Tang, Gangling
    Yang, Fei
    Zhou, Yun
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2020, 58 (08) : 770 - 778
  • [10] Determination of Common Adulterants in Herbal Medicine and Food Samples using Core-shell Column Coupled to Tandem Mass Spectrometry
    Al Lawati, Haider A. J.
    Al Busaidi, Idris
    Kadavilpparampu, Afsal M.
    Suliman, FakhrEldin O.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (03) : 232 - 242