Nano iron porphyrinated poly(amidoamine) dendrimer mobil composition matter-41 for extraction of N-nitrosodiphenylamine nitrosamine from water samples

被引:16
|
作者
Sanagi, Mohd Marsin [1 ,2 ]
Chong, Mun Hwa [1 ]
Endud, Salasiah [1 ]
Ibrahim, Wan Aini Wan [1 ]
Ali, Imran [3 ]
机构
[1] Univ Teknol Malaysia, Fac Sci, Dept Chem, Utm Johor Bahru 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Ibnu Sina Inst Fundamental Sci Studies, Utm Johor Bahru 81310, Johor, Malaysia
[3] Jamb Millia Islamia Cent Univ, Dept Chem, New Delhi 110025, India
关键词
Iron-porphyrin; Dendrimers; MCM-41; Nitrosamines; Solid-phase membrane tip extraction; SOLID-PHASE MICROEXTRACTION; SUPERCRITICAL-FLUID EXTRACTION; VOLATILE NITROSAMINES; DRINKING-WATER; MASS-SPECTROMETRY; WASTE-WATER; PRODUCTS; NDMA; NITROSODIMETHYLAMINE; SURFACE;
D O I
10.1016/j.micromeso.2015.04.011
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Functionalized metalloporphyrin [5,10,15,20-tetrakis-(4-carboxyphenyl)-porphyrin] was coupled with poly(amidoamine) (PAMAM) to form an adduct of iron porphyrin PAMAM dendrimer Mobil Composition Matter-41 (MCM-41) (FeP/Dend-MCM-41). MCM-41 was used as a mesoporous nanomaterial support for FeP/Dend to control pores for adsorption. The materials obtained were characterized by X-ray diffraction, Fourier-transform infrared spectroscopy, diffuse-reflectance ultraviolet visible spectroscopy, H-1 nuclear magnetic resonance, field-emission scanning electron microscopy, transmission electron microscopy, and fluorescence spectroscopy. The performance of the synthesized FeP/Dend-MCM-41 adsorbent in solid-phase membrane tip extraction (SPMTE) was evaluated for the extraction of N-nitrosodiphenylamine (NDPhA) nitrosamine from water samples prior to high-performance liquid chromatography (HPLC). Under the optimized conditions, the method showed good linearity with coefficients of determination R-2 > 0.995 in the concentration range of 1-10,000 ng mL(-1). The method offered good limits of detection (0.96 ng mL(-1)) and limits of quantification (3.21 ng mL(-1)) and analyte recoveries in the range of 97-105% with RSD < 8% at 1 ng mL(-1). The developed FeP/Dend-MCM-41-G3-SPMTE coupled with HPLC method was successfully used for trace analyses of NDPhA in selected water samples (drinking water, tap water, lake water and waste water). (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 3 条
  • [1] Determination of N-nitrosamines in water by nano iron-porphyrinated poly(amidoamine) dendrimer MCM-41 generation-3 through solid phase membrane tip extraction and HPLC
    Chong, Mun Hwa
    Sanagi, Mohd Marsin
    Endud, Salasiah
    Ibrahim, Wan Aini Wan
    Lau, Su Chien
    Alharbi, Omar M. L.
    Ali, Imran
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2018, 10 : 102 - 110
  • [2] Magnetic Poly(Amidoamine) Dendrimer for the Dispersive Solid Phase Extraction of Nitrophenols from Environmental Water Samples
    Ghanbarnejad, Hadi
    Ghoulipour, Vanik
    Khalilian, Faezeh
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2024, 112 (04)
  • [3] Mobil catalytic material number 41 modified magnetite nano-composites for efficient extraction of non-steroidal anti-inflammatory drugs from tap water and urine samples
    Kumar, Sandeep
    Bhogal, Shikha
    Sharma, Promila
    Rani, Susheela
    Aulakh, Jatinder Singh
    Malik, Ashok Kumar
    SEPARATION SCIENCE PLUS, 2022, 5 (08) : 357 - 367