Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair

被引:25
|
作者
Baril, Donald T. [1 ]
Silverberg, Daniel [1 ]
Ellozy, Sharif H. [1 ]
Carroccio, Alflo [1 ]
Jacobs, Tikva S. [1 ]
Sachdev, Ulka [1 ]
Teodorescu, Victoria J. [1 ]
Lookstein, Robert A. [1 ]
Marin, Michael L. [1 ]
机构
[1] Mt Sinai Sch Med, Dept Surg, Div Vasc Surg, New York, NY 10029 USA
关键词
D O I
10.1016/j.avsg.2007.10.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
Despite high initial technical success, the long-term durability of endovascular abdominal aortic aneurysm repair (EVAR) continues to be a concern. Following EVAR, patients can experience endoleaks, device migration, device fractures, or aneurysm growth that may require intervention. The purpose of this study was to review all patients treated with secondary enclovascular devices at our institution for failed EVAR procedures. Over an 8-year period, 988 patients underwent EVAR, of whom 42 (4.3%) required secondary interventions involving placement of additional enclovascular devices. Data regarding patient characteristics, aneurysm size, initial device type, time until failure, failure etiology, secondary interventions, and outcomes were reviewed. The mean time from initial operation until second operation was 34.1 months. Failures included type I endoleaks in 38 patients (90.5%), type III endoleaks in two patients (4.8%), and enlarging aneurysms without definite encloleaks in two patients (4.8%). The overall technical success rate for secondary repair was 92.9% (39/42). Perioperative complications occurred in nine patients (21.4%), including wound complications (n = 6), cerebrovascular accident (CVA) (n = 1), foot drop (n = 1), and death (n = 1). Mean follow-up following secondary repair was 16.4 months (range 1-50). Eighty-six percent of patients treated with aorlouni-iliac devices had successful repairs compared to 45% of patients treated with proximal cuffs. Ten patients (23.8%) had persistent or recurrent type I or type III encloleaks following revision. Of these, four had tertiary interventions, including two patients who had additional devices placed. Failures following EVAR occur in a small but significant number of patients. When anatomically possible, enclovascular revision offers a safe means of treating these failures. Aortouni-iliac devices appear to offer a more durable repair than the proximal cuff for treatment of proximal type I endoleaks. Midterm results indicate that these patients may require additional procedures but have a low rate of aneurysm-related mortality. Longer-term follow-up is necessary to determine the durability of these enclovascular revisions.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 50 条
  • [1] The choice of stent-graft for endovascular repair of abdominal aortic aneurysm
    Chuter, TAM
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04): : 519 - 525
  • [2] Results of Endovascular Abdominal Aortic Aneurysm Repair with the Zenith stent-graft
    Bos, W. T. G. J.
    Tielliu, I. F. J.
    Zeebregts, C. J.
    Prins, T. R.
    van den Dungen, J. J. A. M.
    Verhoeven, E. L. G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (06) : 653 - 660
  • [3] Stent-graft migration after endovascular repair of abdominal aortic aneurysm
    Kalliafas, S
    Albertini, JN
    Macierewicz, J
    Yusuf, SW
    Whitaker, SC
    Davidson, I
    Hopkinson, BR
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (06) : 743 - 747
  • [4] Flow patterns in an endovascular stent-graft for abdominal aortic aneurysm repair
    Chong, CK
    How, TV
    JOURNAL OF BIOMECHANICS, 2004, 37 (01) : 89 - 97
  • [5] Endovascular stent-graft repair of descending aortic aneurysm
    Soeparwata, R
    Vestring, T
    Reimer, P
    Etz, C
    Hammel, D
    Schmitt, C
    Scheld, HH
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (02): : 207 - 207
  • [6] Endovascular repair of abdominal aortic aneurysm using a pararenal fenestrated stent-graft
    Faruqi, RM
    Chuter, TAM
    Reilly, LM
    Sawhney, R
    Wall, S
    Canto, C
    Messina, LM
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (04): : 354 - 358
  • [7] Endovascular Stent-Graft Repair of a Tuberculous Mycotic Aortic Aneurysm
    Han, Daniel K.
    Chung, Christine
    Walkup, Maggie H.
    Faries, Peter L.
    Marin, Michael L.
    Ellozy, Sharif H.
    ANNALS OF VASCULAR SURGERY, 2011, 25 (05) : 699.e13 - 699.e16
  • [8] Endovascular stent-graft repair for abdominal aortic aneurysm in a patient with cardiac and renal dysfunction
    Handa N.
    Tomita S.
    Kato M.
    Nishio I.
    Asano M.
    Ueno Y.
    General Thoracic and Cardiovascular Surgery, 2009, 57 (4) : 203 - 207
  • [9] Endovascular aneurysm repair with the talent stent-graft
    Cowie, AG
    Ashleigh, RJ
    England, RE
    McCollum, CN
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (08) : 1011 - 1016
  • [10] The use of adenosine for stent-graft deployment during endovascular abdominal aortic aneurysm repair
    Kahn, RA