Use of a customized vision model to analyze the effects of higher-order ocular aberrations and neural filtering on contrast threshold performance

被引:23
|
作者
Dalimier, Eugenie [1 ]
Dainty, Chris [1 ]
机构
[1] Natl Univ Ireland, Dept Expt Phys, Appl Opt Grp, Galway, Ireland
基金
爱尔兰科学基金会;
关键词
D O I
10.1364/JOSAA.25.002078
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Customized optical filtering and light-dependent neural filtering were implemented in an ideal-observer model for an L-alternative forced-choice visual task. The model was applied to a contrast threshold visual task with adaptive optics correction of ocular higher-order (HO) aberrations under different light regimes, for which experimental data have previously been obtained (J. Mod. Opt. 55, 791, 2008). A separability measure was used to assess the model-observer performance and to investigate the joint effect of optical and neural filtering. The numerical results were consistent with the experimental data in the assessment of the effect of HO aberrations as a function of light level. (C) 2008 Optical Society of America.
引用
收藏
页码:2078 / 2087
页数:10
相关论文
共 25 条
  • [1] Ocular higher-order aberrations in eyes with supernormal vision.
    Levy, Y
    Segal, O
    Avni, I
    Zadok, D
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (02) : 225 - 228
  • [3] Mesopic contrast sensitivity and ocular higher-order aberrations after overnight orthokeratology
    Hiraoka, Takahiro
    Okamoto, Chikako
    Ishii, Yuko
    Takahira, Tomonori
    Kakita, Tetsuhiko
    Oshika, Tetsuro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (04) : 645 - 655
  • [4] Contrast sensitivity function and ocular higher-order aberrations following overnight orthokeratology
    Hiraoka, Takahiro
    Okamoto, Chikako
    Ishii, Yuko
    Kakita, Tetsuhiko
    Oshika, Tetsuro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (02) : 550 - 556
  • [5] Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes
    Sabesan, Ramkumar
    Jeong, Tae Moon
    Carvalho, Luis
    Cox, Ian G.
    Williams, David R.
    Yoon, Geunyoung
    OPTICS LETTERS, 2007, 32 (08) : 1000 - 1002
  • [6] Ocular higher-order aberrations and contrast sensitivity after conventional laser in situ keratomileusis
    Yamane, N
    Miyata, K
    Samejima, T
    Hiraoka, T
    Kiuchi, T
    Okamoto, F
    Hirobara, Y
    Mihashi, T
    Oshika, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (11) : 3986 - 3990
  • [7] Ocular higher-order aberrations and contrast visual function after laser in situ keratomileusis
    Yamane, N
    Sato, M
    Hiraoka, T
    Okamoto, F
    Kaji, Y
    Oshika, T
    Samejima, T
    Miyata, K
    Hirohara, Y
    Mihashi, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U25 - U25
  • [8] Contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes
    Oshika, Tetsuro
    Okamoto, Chikako
    Samejima, Tomokazu
    Tokunaga, Tadatoshi
    Miyata, Kazunori
    OPHTHALMOLOGY, 2006, 113 (10) : 1807 - 1812
  • [9] Effects of higher-order aberrations on contrast acuity as a function of light level
    Dalimier, Eugenie
    Dainty, Chris
    Barbur, John L.
    JOURNAL OF MODERN OPTICS, 2008, 55 (4-5) : 791 - 803
  • [10] Blue-Light Filtering Intraocular Implants and Darker Irises Reduce the Behavioral Effects of Higher-Order Ocular Aberrations
    Renzi-Hammond, Lisa M.
    Hammond, Billy R., Jr.
    CURRENT EYE RESEARCH, 2022, 47 (05) : 753 - 758