Changes in jugular bulb oxygen saturation during off-pump coronary artery bypass graft surgery

被引:7
|
作者
Kim, JY
Kwak, YL
Oh, YJ
Kim, SH
Yoo, KJ
Hong, YW
机构
[1] Yonsei Univ, Sch Med, Dept Cardiothorac Surg, Seoul 120752, South Korea
[2] Gachon Med Sch, Gil Med Ctr, Dept Anesthesiol & Pain Med, Seoul, South Korea
[3] Pain Res Inst, Seoul, South Korea
[4] Yonsei Cardiovasc Res Inst, Seoul, South Korea
关键词
jugular bulb oxygen saturation; off-pump coronary artery bypass; brain ischemia;
D O I
10.1111/j.1399-6576.2005.00739.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The effect of haemodynamic derangement during coronary artery anastomosis in off-pump coronary artery bypass surgery on cerebral blood flow has not been elucidated. Jugular bulb oxygen saturation is a useful indicator of cerebral blood flow provided that the cerebral metabolic rate is constant. This study was designed to evaluate the changes in jugular bulb oxygen saturation during off-pump coronary artery bypass surgery. Methods: With IRB approval, 48 patients were included. After anaesthesia, an 18-G catheter was introduced into the jugular bulb. Haemodynamic variables and oxygen profiles from gas analysis of jugular bulb blood and arterial blood were obtained: after sternotomy (baseline); at 5 min after the beginning of the anastomosis of the left anterior descending artery, obtuse marginal artery, and right coronary artery; and after sternal closure. Results: Cardiac index and mixed venous oxygen saturation decreased significantly during anastomosis of all three arteries compared to the baseline value. Although the changes in jugular bulb oxygen saturation during anastomosis were statistically significant compared to its baseline value, jugular bulb oxygen saturation remained within normal limit throughout the study. Conclusions: Jugular bulb oxygen saturation, which represents the global cerebral oxygenation, was well maintained during the anastomosis of all coronary arteries despite significant haemodynamic changes during off-pump coronary artery bypass (OPCAB).
引用
收藏
页码:956 / 961
页数:6
相关论文
共 50 条
  • [1] Change in the jugular bulb oxygen saturation during off-pump coronary artery bypass graft surgery
    Kwak, Y
    Lee, J
    Shim, Y
    Kim, S
    Oh, Y
    Hong, Y
    ANESTHESIA AND ANALGESIA, 2004, 98 (04): : 11 - 11
  • [2] Jugular bulb desaturation during off-pump coronary artery bypass surgery
    Norikazu Miura
    Kenji Yoshitani
    Masahiko Kawaguchi
    Masahide Shinzawa
    Tomoya Irie
    Osamu Uchida
    Yoshihiko Ohnishi
    G. Burkhard Mackensen
    Journal of Anesthesia, 2009, 23 : 477 - 482
  • [3] Jugular bulb desaturation during off-pump coronary artery bypass surgery
    Miura, Norikazu
    Yoshitani, Kenji
    Kawaguchi, Masahiko
    Shinzawa, Masahide
    Irie, Tomoya
    Uchida, Osamu
    Ohnishi, Yoshihiko
    Mackensen, G. Burkhard
    JOURNAL OF ANESTHESIA, 2009, 23 (04) : 477 - 482
  • [4] Assessment of cerebral oxygen balance during off-pump coronary artery bypass (OPCAB) surgery by jugular bulb venous saturation
    Ha, S.
    Lee, E.
    Jeong, Y.
    Hahm, K.
    Lee, Y.
    Choi, I
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 : 9 - 9
  • [5] Diabetes mellitus does not affect jugular bulb oxygen saturation in patients undergoing off-pump coronary artery bypass graft surgery
    Oh, Young Jun
    Kim, Ji Young
    Shim, Jae Kwang
    Yoo, Kyung Jong
    Lee, Jong Wha
    Kwak, Young Lan
    CIRCULATION JOURNAL, 2008, 72 (08) : 1259 - 1264
  • [6] Hemodynamic changes during off-pump coronary artery bypass graft surgery
    D'Ancona, G
    Karamanoukian, H
    Bergsland, J
    Salerno, T
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (02) : 235 - 236
  • [7] Application of central venous oxygen saturation monitoring during off-pump coronary artery bypass graft surgery
    Wu, Kuan
    Guo, Tao
    Wang, Yijun
    CARDIOLOGY, 2013, 126 : 114 - 115
  • [8] Application of central venous oxygen saturation monitoring during off-pump coronary artery bypass graft surgery
    Wu, Kuan
    Guo, Tao
    Wang, Yijun
    CARDIOLOGY, 2013, 126 : 115 - 115
  • [9] Jugular bulb desaturation during coronary artery surgery: a comparison of off-pump and on-pump procedures
    Diephuis, JC
    Moons, KGM
    Nierich, AN
    Bruens, M
    van Dijk, D
    Kalkman, CJ
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (06) : 715 - 720
  • [10] Patency in off-pump coronary artery bypass graft surgery
    Zamvar, V
    HEART SURGERY FORUM, 2004, 7 (03): : E214 - E215