Evaluation of the suitability of different chiller performance models for on-line training applied to automated fault detection and diagnosis (RP-1139)

被引:32
|
作者
Reddy, TA [1 ]
Niebur, D
Andersen, KK
Pericolo, PP
Cabrera, G
机构
[1] Drexel Univ, Dept Civil Environm & Architectural Engn, Philadelphia, PA 19104 USA
[2] Drexel Univ, Dept Elect & Comp Engn, Philadelphia, PA 19104 USA
[3] Drexel Univ, Dept Mech Engn & Mech, Philadelphia, PA 19104 USA
[4] Tech Univ Denmark, Dept Math Modeling, DK-2800 Lyngby, Denmark
来源
HVAC&R RESEARCH | 2003年 / 9卷 / 04期
关键词
D O I
10.1080/10789669.2003.10391077
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the research results of comparing the suitability of four different chiller performance models to be used for on-line automated fault detection and diagnosis (FDD) of vapor-compression chillers. The models were limited to steady-state performance and included (a) black-box multivariate polynomial (MP) models; (b) artificial neural network (ANN) models, specifically radial basis function (RBF) and multilayer perceptron (MLP); (c) the generic physical component (PC) model approach; and (d) the lumped physical Gordon-Ng (GN) model. All models except for (b) are linear in the parameters. A review of the engineering literature identified the three following on-line training schemes as suitable for evaluation: ordinary recursive least squares (ORLS) under incremental window scheme, sliding window scheme, and weighted recursive least squares (WRLS) scheme, where more weight is given to newer data. The evaluation was done based on five months of data from a 220 ton field-operated chiller from Toronto (a data set of 810 data points) and fourteen days of data from a 450 ton field-operated chiller (a set of about 1120 data points) located on Drexel University campus. The evaluation included a preliminary off-line or batch analysis to gain a first understanding of the suitability of the various models and their particular drawbacks and then to investigate whether the different chiller models exhibit any time variant or seasonal behavior. The subsequent on-line evaluation consisted of assessing the various models in terms of their suitability for model parameter tracking as well as model prediction accuracy (which would provide the necessary thresholds for flagging occurrence of faults). The former assessment suggested that parameter tracking using the GN model parameters could be a viable option for fault detection (FD) implementation, while the black box models were not at all suitable given their high standard errors. The assessment of models in terms of their internal prediction accuracy revealed that the MLP model was best, followed by the MP and GN models. However, the more important test of external predictive accuracy suggests that all models are equally accurate (CV about 2% to 4%) and, hence, comparable within the experimental uncertainty of the data. ORLS with incremental window scheme was found to be the most robust compared to the other computational schemes. The chiller models do not exhibit any time variant behavior since WRLS was found to be poorest. Finally, in terms of the initial length of training data, it was determined-at least with the data sets used that exhibited high autocorrelation-that about 320 and 400 data points would be respectively necessary for the MP and GN model parameter estimates to stabilize at their long-term values. This paper also provides a detailed discussion of the potential advantages that on-line model training can offer and identifies areas of follow-up research.
引用
收藏
页码:385 / 414
页数:30
相关论文
共 6 条
  • [1] Inference mechanisms applied to on-line electro-pneumatic fault detection and diagnosis
    Evans, DS
    MECHATRONICS '98, 1998, : 763 - 768
  • [2] Performance Evaluation of Chiller Fault Detection and Diagnosis Using Only Field-Installed Sensors
    Wang, Zhanwei
    Guo, Jingjing
    Zhou, Sai
    Xia, Penghua
    PROCESSES, 2023, 11 (12)
  • [3] Evaluation of different lactation curve models fitted for milk viscosity recorded by an automated on-line California Mastitis Test
    Neitzel, Anne-Christin
    Stamer, Eckhard
    Junge, Wolfgang
    Thaller, Georg
    JOURNAL OF DAIRY RESEARCH, 2015, 82 (02) : 185 - 192
  • [4] Performance Evaluation of On-Line Transformer Winding Short Circuit Fault Detection Based on Instantaneous Voltage and Current Measurements
    Masoum, Ali S.
    Hashemnia, Naser
    Abu-Siada, A.
    Masoum, Mohammad A. S.
    Islam, Syed M.
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [5] Applied study of on-line evaluation for operating performance of 102J turbo-compressor sets based on thermodynamic parameter diagnosis
    Zheng, Han-tao
    Wang, Xiao-fang
    Wang, Wei
    Sun, Yong-mao
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 529 - 532
  • [6] Development of a fully automated on-line solid phase extraction and high-performance liquid chromatography with diode array detection method for the pharmacokinetic evaluation of bavachinin: A study on absolute bioavailability and dose proportionality
    Liu, Lei
    Liu, Kang-Ning
    Wen, Ya-Bin
    Zhang, Han-Wen
    Lu, Ya-Xin
    Yin, Zheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 893 : 21 - 28