Preoperative levosimendan infusion in combined aortic valve and coronary bypass surgery

被引:55
|
作者
Leppikangas, H. [1 ]
Jarvela, K. [2 ]
Sisto, T. [2 ]
Maaranen, P. [2 ]
Virtanen, M. [2 ]
Lehto, P. [2 ]
Karlsson, S. [3 ]
Koobi, T. [4 ]
Lindgren, L. [1 ]
机构
[1] Tampere Univ Hosp, Dept Anaesthesia, Tampere 33521, Finland
[2] Tampere Univ Hosp, Ctr Heart, Tampere 33521, Finland
[3] Tampere Univ Hosp, Dept Intens Care, Tampere 33521, Finland
[4] Tampere Univ Hosp, Dept Clin Physiol, Tampere 33521, Finland
关键词
heart; coronary artery bypass; inotropism; surgery; cardiovascular; BODY IMPEDANCE CARDIOGRAPHY; LEFT-VENTRICULAR FUNCTION; CONGESTIVE-HEART-FAILURE; CARDIAC-OUTPUT; CARDIOPULMONARY BYPASS; ATP CHANNELS; K-ATP; THERMODILUTION; DOBUTAMINE; ACTIVATION;
D O I
10.1093/bja/aeq402
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Cardiopulmonary bypass may have detrimental effects on intestinal function and decrease the concentrations of the active, long-acting metabolites of levosimendan, an inodilator used to improve cardiac function. The aim of this study was to evaluate the haemodynamic effects of preoperative levosimendan in patients undergoing high-risk cardiac surgery. Methods. Twenty-four patients were randomized to receive levosimendan (12 mu g bolus followed by an infusion of 0.2 mu g kg(-1) min(-1)) or a placebo 24 h before surgery. The inclusion criteria were left ventricular ejection fraction (LVEF) <50% or LV hypertrophy indicated by a wall thickness of >12 mm. Haemodynamics were recorded every hour for 24 h (pulmonary artery catheter) and daily until postoperative day 4 (whole-body impedance cardiography). Doppler echocardiography with tissue Doppler imaging was used to assess systolic and diastolic cardiac function. Results. The cardiac index (CI) and stroke volume index (SI) were higher in the levosimendan group (LG) for the 4 day postoperative period (P < 0.05); on the fourth postoperative day, the CI was 3.0 litre m(-2) min(-1) in the LG compared with 2.4 litre m(-2) min(-1) in the control group (CG) and the SI was 30 vs 25 ml m(-2), respectively. The LVEF measured at baseline and on the fourth postoperative morning decreased in the CG, but was maintained in the LG. Conclusions. Levosimendan improved haemodynamics compared with a placebo in patients undergoing high-risk cardiac surgery. The concentrations of levosimendan's metabolites were higher compared with earlier studies using perioperative dosing.
引用
收藏
页码:298 / 304
页数:7
相关论文
共 50 条
  • [1] COMBINED AORTIC-VALVE REPLACEMENT AND CORONARY-ARTERY BYPASS GRAFT SURGERY
    BERNDT, T
    HANCOCK, EW
    HARRISON, DC
    CIRCULATION, 1973, 48 (04) : 74 - 74
  • [2] Selection of techniques for combined valve surgery and coronary artery bypass grafting: The impact of combined procedures involving the aortic or mitral valve
    Cohn, LH
    Soltesz, EG
    PATHOPHYSIOLOGY, EVALUATION AND MANAGEMENT OF VALVULAR HEART DISEASES, VOL 2, 2004, 41 : 164 - 171
  • [3] Comparison of Risk 'Scores' Performances for Combined Aortic Valve Replacement and Coronary Artery Bypass Surgery
    Nezic, Dusko
    HEART LUNG AND CIRCULATION, 2017, 26 (11): : E93 - E94
  • [4] Comparing Performance of Risk Scores for Combined Aortic Valve Replacement and Coronary Bypass Grafting Surgery
    Wang, Tom Kai Ming
    Choi, David H. M.
    Ramanathan, Tharumenthiran
    Ruygrok, Peter N.
    HEART LUNG AND CIRCULATION, 2016, 25 (11): : 1118 - 1123
  • [5] Transesophageal echocardiographic diagnosis of aortic pseudoaneurysm after combined aortic valve replacement and coronary artery bypass graft surgery
    Smith, B
    Lekowski, R
    Byrne, JG
    Collard, CD
    ANESTHESIA AND ANALGESIA, 1999, 89 (03): : 802 - 802
  • [7] Leukocyte filter enhances neutrophil activation during combined aortic valve and coronary artery bypass surgery
    Koskenkari, Juha K.
    Rimpilaeinen, Jussi
    Oehman, Hanna
    Surcel, Heljae-Marja
    Vainionpaeae, Vilho
    Biancari, Fausto
    Ala-Kokko, Tero
    Juvonen, Tatu
    HEART SURGERY FORUM, 2006, 9 (04): : E693 - E699
  • [8] Levosimendan in aortic valve surgery:: Cardiac performance and recovery
    Jarvela, Kati
    Maaranen, Pasi
    Sisto, Tero
    Ruokonen, Esko
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (05) : 693 - 698
  • [9] AORTIC-VALVE REPLACEMENT COMBINED WITH AORTOCORONARY BYPASS-SURGERY
    VALLI, C
    ROTHLIN, M
    TURINA, M
    SENNING, A
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1983, 113 (45) : 1696 - 1697
  • [10] Aortic valve replacement in patients with mild or moderate aortic stenosis and coronary bypass surgery
    Pereira, JJ
    Balaban, K
    Lauer, MS
    Lytle, B
    Thomas, JD
    Garcia, MJ
    AMERICAN JOURNAL OF MEDICINE, 2005, 118 (07): : 735 - 742