Increased Accuracy After Adjustment of Spirometry Threshold for Diagnosing COPD Based on Pre-Bronchodilator FEV1/FVC

被引:5
|
作者
Kronborg, Thomas [1 ]
Hangaard, Stine [1 ]
Cichosz, Simon Lebech [1 ]
Hejlesen, Ole [1 ]
机构
[1] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
关键词
COPD; spirometry; pre-bronchodilator; diagnosis; assessment; OBSTRUCTIVE PULMONARY-DISEASE; AIR-FLOW OBSTRUCTION; LOWER LIMIT; CRITERIA; RATIO; DEFINITIONS; PREVALENCE; PERCENTAGE; RISK;
D O I
10.4187/respcare.06148
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: COPD is a leading cause of morbidity and mortality worldwide. Spirometry is the most common lung function test for diagnosing COPD with a post-hroncluxlilator FEV1/FVC < 0.70 confirming the presence of the disease. However, diagnosticians appear reluctant to use bronchodilators, which have been linked to the misdiagnosis of COPD. Therefore, we investigated whether the threshold for diagnosing COPD should be modified when diagnosing COPD based on pre-bronchodilator spirometry. METHODS: Data from 23,433 participants were merged from the National Health and Nutrition Examination Survey (NHANES) 2007-2012. Participants were excluded for having no post-bronchodilator spirometry, for being below the age of 40, and for having asthma or lung cancer. These exclusion criteria resulted in 680 participants being included in the present study. Participants with COPD were defined as those with a post-bronchodilator FEV1/FVC < 0.70. The threshold for diagnosing COPD based on pre-bronchodilator FEV1/FVC was varied while calculating accuracy. sensitivity, specificity, positive predictive value, and negative predictive value. RESULTS: Diagnosing COPD based on pre-bronchodilator FEV1/FVC < 0.70 contributes to the misdiagnosis of COPD through poor classification rates. By adjusting the threshold and diagnosing COPD based on a pre-bronchodilator FEV1/PVC < 0.66, the overall classification rates increase noticeably, resulting in a 15% increase in accuracy. CONCLUSION: We suggest a slight adjustment using pre-bronchodilator FEV1/FVC < 0.66 when diagnosing COPD based on pre-bronchodilator spirometry. This approach could prevent cases of misdiagnosed COPD, which can lead to potentially harmful treatment of people who do not have COPD and foregone treatment in patients with COPD.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 32 条
  • [1] Decreased pre-bronchodilator FEV1 as a potential risk factor for COPD
    Masuko, H.
    Sakamoto, T.
    Ano, S.
    Fujita, J.
    Yageta, Y.
    Yamadori, T.
    Kikuchi, N.
    Haraguchi, N.
    Homma, S.
    Kawaguchi, M.
    Morishima, Y.
    Ishii, Y.
    Iijima, H.
    Naito, T.
    Hizawa, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [2] Using Post-bronchodilator FEV1 is Better Than Pre-bronchodilator FEV1 in Evaluation of COPD Severity
    Chen, Chiung-Zuei
    Ou, Chih-Ying
    Wang, Wen-Ling
    Lee, Cheng-Hung
    Lin, Chien-Chung
    Chang, Han-Yu
    Hsiue, Tzuen-Ren
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2012, 9 (03) : 276 - 280
  • [3] People with older age and lower FEV1%pred tend to have a smaller FVC than VC in pre-bronchodilator spirometry
    Wang, Wenqiao
    Ma, Dedong
    Li, Tiantian
    Ying, Yangyang
    Xiao, Wei
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2014, 194 : 1 - 5
  • [4] Evaluation of normal pre-bronchodilator FEV1/VCMax in the context of significant bronchodilator responsiveness
    Evans, Dominic
    Khan, Muhammad
    Apen, Calvin
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [5] Assessing two spirometric criteria of pre-bronchodilator and post-bronchodilator FEV1/FVC ratio in detecting air flow obstruction
    Waheed, Zeeshan
    Irfan, Muhammad
    Haque, Ahmed Suleman
    Siddiqui, Najmul Hasan
    Awan, Safia
    Syed, Beenish
    Khan, Javaid Ahmed
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2011, 61 (12) : 1172 - 1175
  • [6] Population modeling of pre-bronchodilator FEV1 response to benralizumab treatment in patients with severe asthma
    Yan, Li
    Wang, Bing
    Yu, Binbing
    Barker, Peter
    Goldman, Mitchell
    Roskos, Lorin
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2017, 44 : S128 - S129
  • [7] Discriminative Accuracy of FEV1: FVC Thresholds for COPD-Related Hospitalization and Mortality
    Bhatt, Surya P.
    Balte, Pallavi P.
    Schwartz, Joseph E.
    Cassano, Patricia A.
    Couper, David
    Jacobs, David R., Jr.
    Kalhan, Ravi
    O'Connor, George T.
    Yende, Sachin
    Sanders, Jason L.
    Umans, Jason G.
    Dransfield, Mark T.
    Chaves, Paulo H.
    White, Wendy B.
    Oelsner, Elizabeth C.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2019, 321 (24): : 2438 - 2447
  • [8] Lower limit of normal or FEV1/FVC &lt;0.70 in diagnosing COPD: An evidence-based review
    Hoesein, Firdaus A. A. Mohamed
    Zanen, Pieter
    Lammers, Jan-Willem J.
    RESPIRATORY MEDICINE, 2011, 105 (06) : 907 - 915
  • [9] Pre-Transplant FEV1/FVC but Not FEV1 Alone by Pulmonary Function Testing Predicts Poor Outcome after Heart Transplantation: The Bane of COPD
    Patel, J.
    Shao, E.
    Patel, J.
    Kawano, M.
    Kiyosaki, K.
    Ankrom, A.
    Kittleson, M.
    Moriguchi, J.
    Aradebali, A.
    Kobashigawa, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S264 - S264
  • [10] Diagnostic accuracy of pre-bronchodilator FEV1/FEV6 from microspirometry to detect airflow obstruction in primary care: a randomised cross-sectional study
    van den Bemt, Lisette
    Wouters, Bram C. W.
    Grootens, Joke
    Denis, Joke
    Poels, Patrick J.
    Schermer, Tjard R.
    NPJ PRIMARY CARE RESPIRATORY MEDICINE, 2014, 24