Application and discussion on entransy analysis of ammonia/salt absorption heat pump systems

被引:1
|
作者
Yang, Lei [1 ,2 ,3 ,4 ]
Huang, Sihao [1 ,2 ,3 ,4 ]
Lu, Zhenneng [1 ,2 ,3 ]
Gong, Yulie [1 ,2 ,3 ]
Li, Huashan [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China
[2] CAS Key Lab Renewable Energy, Guangzhou 510640, Peoples R China
[3] Guangdong Prov Key Lab New & Renewable Energy Res, Guangzhou 510640, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
entransy; exergy; absorption heat pump; ammonia/salt; performance analysis; PLUS LITHIUM-NITRATE; THERMODYNAMIC ANALYSIS; REFRIGERATION CYCLE; HOT-WATER; NH3-NASCN; NH3-LINO3; TECHNOLOGIES; VISCOSITIES; PERFORMANCE; CAPACITIES;
D O I
10.1093/ijlct/ctab027
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the application of the entransy analysis in ammonia/salt absorption heat pump (AHP) systems. The results of the entransy analysis are compared with those of energy analysis and exergy analysis under typical and various operating conditions. Entransy dissipation and exergy loss in each component, as well as coefficient of performance (COP), exergy efficiency and entransy efficiency of systems, are discussed. The changing trends of entransy dissipation in each component are similar under various operating conditions. However, the entransy analysis performs better than the exergy analysis in evaluating the irreversible loss of each component. Moreover, the differences between the exergy analysis and entransy analysis are mainly in absorber, generator and SHE. Especially in the NH3/NaSCN system, the proportion of entransy dissipation in generator is 60.8%, which is almost twice of the proportion of exergy loss (34.9%). In addition, under various operating conditions, entransy efficiency and COP have roughly the same changing trend. Meanwhile, entransy efficiency is more reasonable than exergy efficiency in evaluating the performance of systems under the absorption temperature, which varies from 30 degrees C to 50 degrees C. These comparison results demonstrate that the entransy analysis is appropriate to evaluate the performance of ammonia/salt AHP systems and suitable for analyzing the irreversibility of each component.
引用
收藏
页码:977 / 986
页数:10
相关论文
共 50 条
  • [1] Entransy and entropy analyses of heat pump systems
    CHENG XueTao
    LIANG XinGang
    Science Bulletin, 2013, (36) : 4696 - 4702
  • [2] Entransy and entropy analyses of heat pump systems
    CHENG XueTao
    LIANG XinGang
    Chinese Science Bulletin, 2013, 58 (36) : 4696 - 4702
  • [3] Entransy and entropy analyses of heat pump systems
    Cheng XueTao
    Liang XinGang
    CHINESE SCIENCE BULLETIN, 2013, 58 (36): : 4696 - 4702
  • [4] Theoretical perfection and application of entransy analysis method on absorption systems
    Yi, Yuhao
    Xie, Xiaoyun
    Zhang, Hao
    Jiang, Yi
    ENERGY, 2024, 307
  • [5] THERMODYNAMIC ANALYSIS ON AN AMMONIA WATER ABSORPTION-RESORPTION SYSTEM FOR HEAT PUMP APPLICATION
    Du, Shuai
    Wang, Ruzhu
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1026 - 1033
  • [6] Entransy based heat exchange irreversibility analysis for a hybrid absorption-compression heat pump cycle
    You, Jinfang
    Zhang, Xi
    Gao, Jintong
    Wang, Ruzhu
    Xu, Zhenyuan
    ENERGY, 2024, 289
  • [7] Design and analysis of an ammonia-water absorption heat pump
    Mirl, Nico
    Schmid, Fabian
    Bierling, Bernd
    Spindler, Klaus
    APPLIED THERMAL ENGINEERING, 2020, 165 (165)
  • [8] Discussion on the applicability of entropy generation minimization and entransy theory to the evaluation of thermodynamic performance for heat pump systems
    Cheng, XueTao
    Liang, XinGang
    ENERGY CONVERSION AND MANAGEMENT, 2014, 80 : 238 - 242
  • [9] Discussion on the application of entransy theory to heat-work conversion processes
    Cheng Xue-Tao
    Liang Xin-Gang
    ACTA PHYSICA SINICA, 2014, 63 (19)
  • [10] FIRST AND SECOND LAW ANALYSIS OF A LABORATORY AMMONIA/WATER ABSORPTION HEAT PUMP
    Moser, Harald
    Rieberer, Rene
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2010, 18 (02) : 117 - 129