Necessity of acceptable radiologic alignment by preoperative closed reduction for unstable distal radius fractures treated with volar locking plates

被引:4
|
作者
Jung, Hyoung-Seok [1 ]
Chun, Kwang-Jin [1 ]
Kim, Jae Yoon [1 ]
Lee, Jae-Sung [1 ]
机构
[1] Hosp Chung Ang Univ Med, Dept Orthopaed Surg, 224-1 Heukseok Dong, Seoul 156755, South Korea
关键词
Distal radius fracture; Closed reduction; Volar locking plate; Radiologic alignment; INSTABILITY; PREDICTORS; STABILITY; FIXATION; ARM;
D O I
10.1007/s00068-020-01322-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose The purpose of this study was to demonstrate the necessity of achieving acceptable radiographic alignment by preoperative closed reduction in unstable distal radius fractures (DRFs) to improve preoperative pain and obtain satisfactory outcomes after surgery. Methods From 2013 to 2016, patients who received volar locking plates for DRFs were retrospectively reviewed. Patients were classified into acceptable and non-acceptable reduction groups based on immediate post-reduction radiographs. To avoid potential bias, a matched-pair analysis was performed, and paired patients were categorized into non-acceptable reduction (group A) and acceptable reduction (group B) groups. Preoperative pain level, mean length of stay, operation time, postoperative complications, and surgical outcomes were analysed. The preoperative pain level and functional results were assessed by the visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) scores. Results Of the 239 patients, 80 had non-acceptable and 159 had acceptable reductions. Among these patients, 201 (66 in group A vs. 135 in group B) were matched in a 1:2 matched ratio. Although the radiological parameters after closed reduction were better in group B, there were no significant differences in the preoperative pain VAS score, mean length of stay, operation time, and postoperative complications between the groups. In addition, radiologic parameters and the DASH score at a 1-year follow-up were also not significantly different between the groups. Conclusion Our results suggest that obtaining acceptable radiologic alignment by closed reduction is not necessary for patients who make an informed decision to undergo volar plating for unstable DRFs.
引用
收藏
页码:1881 / 1887
页数:7
相关论文
共 50 条
  • [1] Necessity of acceptable radiologic alignment by preoperative closed reduction for unstable distal radius fractures treated with volar locking plates
    Hyoung-Seok Jung
    Kwang-Jin Chun
    Jae Yoon Kim
    Jae-Sung Lee
    European Journal of Trauma and Emergency Surgery, 2021, 47 : 1881 - 1887
  • [2] Surgical treatment of unstable distal radius fractures with volar locking plates
    Murakami, Kenichi
    Abe, Yoshihiro
    Takahashi, Kazuhisa
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2007, 12 (02) : 134 - 140
  • [3] Radiographic Alignment of Unstable Distal Radius Fractures Fixed With 1 or 2 Rows of Screws in Volar Locking Plates
    Neuhaus, Valentin
    Badri, Omar
    Ferree, Steven
    Bot, Arjan G. J.
    Ring, David C.
    Mudgal, Chaitanya S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (02): : 297 - 301
  • [4] Randomized Comparison of Volar Locking Plates and Intramedullary Nails for Unstable Distal Radius Fractures
    Plate, Johannes F.
    Gaffney, Daniel L.
    Emory, Cynthia L.
    Mannava, Sandeep
    Smith, Beth P.
    Koman, L. Andrew
    Wiesler, Ethan R.
    Li, Zhongyu
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (06): : 1095 - 1101
  • [5] Treatment of unstable distal radius fractures with the volar locking plate
    Minegishi, Hanae
    Dohi, Osamu
    An, Soukan
    Sato, Hidetsugu
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 280 - 284
  • [6] Results of volar locking plating for unstable distal radius fractures
    Sugun, Tahir Sadik
    Gurbuz, Yusuf
    Ozaksar, Kemal
    Toros, Tulgar
    Kayalar, Murat
    Bal, Emin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (01) : 22 - 25
  • [7] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [8] Flexor tendon complications in distal radius fractures treated with volar rim locking plates
    Fardellas, A.
    Vernet, P.
    Facca, S.
    Liverneaux, P.
    HAND SURGERY & REHABILITATION, 2020, 39 (06): : 511 - 515
  • [9] Complications of volar locking plates used to treat distal radius fractures
    Herzberg, G.
    Marc, A.
    Burnier, M.
    HAND SURGERY & REHABILITATION, 2016, 35 : S95 - S98
  • [10] The Necessity of Restoration of Radiologic Parameters by Closed Reduction in Elderly Patients with Distal Radius Fractures
    Kong, Lingde
    Kou, Ningzhao
    Wang, Yanxue
    Lu, Jian
    Tian, Dehu
    Zhang, Bing
    MEDICAL SCIENCE MONITOR, 2019, 25 : 6598 - 6604