Knowledge of the short-circuit impedance variation is necessary for verifying the observance of the technical conditions (including the design conditions), certain nonconformities in the winding execution, checking the winding behavior in operation, verifying the system and short-circuit calculation (including the correct protection setup), the loading of the same type units, or more importantly, of the different type ones. The measurement of the short-circuit impedance by means of a three phase low voltage power source can be performed because the value of impedances does not depend on the applied voltage. ICEMENERG has developed a modem measurement system that has been used for performing a great amount of measurements, the results of which have been compared with those of the manufacturer's, and with those obtained by means of high voltage measurements. Ill. 3, bibl. 8 (in English; summaries in English, Russian and Lithuanian).
引用
收藏
页码:97 / 100
页数:4
相关论文
共 50 条
  • [1] Power Transformer Condition Assessment Using DGA and FRA
    Gonzales, J. C.
    Mombello, E. E.
    IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (11) : 4527 - 4533
  • [2] Condition Assessment for Power Transformer Using Health Index
    Wang Jian
    Wu Kuihua
    Zhu Wenbing
    Gu Chao
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [3] Condition assessment of power transformer using information fusion
    Liao, Rui-Jin
    Huang, Fei-Long
    Yang, Li-Jun
    Zheng, Han-Bo
    Gong, Jing
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (06): : 1455 - 1460
  • [4] Condition Assessment of Power Transformer Using SVM based on DGA
    Singh, Jagdeep
    Kaur, Kulraj
    Kumari, Priyam
    Swami, Ankit Kumar
    2016 AL-SADIQ INTERNATIONAL CONFERENCE ON MULTIDISCIPLINARY IN IT AND COMMUNICATION TECHNIQUES SCIENCE AND APPLICATIONS (AIC-MITCSA), 2016,
  • [5] Condition Assessment of Power Transformer Using Fuzzy and Evidential Theory
    Kari, Tusongjiang
    Gao, Wen-sheng
    Liu, Yu-quan
    Chen, Yu-qiang
    Li, Hua
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 28 - 31
  • [6] Assessment of power transformer insulation condition
    Sokolov, V
    Bulgakova, V
    Berler, Z
    ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 605 - 613
  • [7] THERMAL CONDITION ASSESSMENT OF POWER TRANSFORMER
    Cahyono, Bambang
    Arifianto, Indera
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 60 - +
  • [8] Mechanical-condition Assessment of Power Transformer Using Vibroacoustic Analysis
    Kornatowski, Eugeniusz
    ADVANCED MATERIALS IN MICROWAVES AND OPTICS, 2012, 500 : 40 - 44
  • [9] Power transformer condition assessment using oil UV-Spectrophotometry
    Arshad, M.
    Islam, Syed M.
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 611 - +
  • [10] Significance of Cellulose Power Transformer Condition Assessment
    Arshad, Muhammad
    Islam, Syed M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1591 - 1598