Virtual bronchoscopy-guided lung SAbR: dosimetric implications of using AAA versus Acuros XB to calculate dose in airways

被引:1
|
作者
Kinkopf, P. [1 ]
Modiri, A. [1 ]
Yu, Kun-Chang [2 ]
Yan, Y. [3 ]
Mohindra, P. [1 ]
Timmerman, R. [3 ]
Sawant, A. [1 ]
Vicente, E. [1 ]
机构
[1] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
[2] Broncus Med Inc, San Jose, CA USA
[3] UT Southwestern Med Ctr, Dallas, TX USA
基金
美国国家卫生研究院;
关键词
airways; dose calculation; AAA; acuros; functional avoidance radiotherapy planning; BODY RADIATION-THERAPY; ANALYTICAL ANISOTROPIC ALGORITHM; CLINICAL-IMPLICATIONS; VALIDATION; CANCER;
D O I
10.1088/2057-1976/ac240c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In previous works, we showed that incorporating individual airways as organs-at-risk (OARs) in the treatment of lung stereotactic ablative radiotherapy (SAbR) patients potentially mitigates post-SAbR radiation injury. However, the performance of common clinical dose calculation algorithms in airways has not been thoroughly studied. Airways are of particular concern because their small size and the density differences they create have the potential to hinder dose calculation accuracy. To address this gap in knowledge, here we investigate dosimetric accuracy in airways of two commonly used dose calculation algorithms, the anisotropic analytical algorithm (AAA) and Acuros-XB (AXB), recreating clinical treatment plans on a cohort of four SAbR patients. A virtual bronchoscopy software was used to delineate 856 airways on a high-resolution breath-hold CT (BHCT) image acquired for each patient. The planning target volumes (PTVs) and standard thoracic OARs were contoured on an average CT (AVG) image over the breathing cycle. Conformal and intensity-modulated radiation therapy plans were recreated on the BHCT image and on the AVG image, for a total of four plan types per patient. Dose calculations were performed using AAA and AXB, and the differences in maximum and mean dose in each structure were calculated. The median differences in maximum dose among all airways were <= 0.3Gy in magnitude for all four plan types. With airways grouped by dose-to-structure or diameter, median dose differences were still <= 0.5Gy in magnitude, with no clear dependence on airway size. These results, along with our previous airway radiosensitivity works, suggest that dose differences between AAA and AXB correspond to an airway collapse variation <= 0.7% in magnitude. This variation in airway injury risk can be considered as not clinically relevant, and the use of either AAA or AXB is therefore appropriate when including patient airways as individual OARs so as to reduce risk of radiation-induced lung toxicity.
引用
收藏
页数:11
相关论文
共 10 条
  • [1] Virtual Bronchoscopy-Guided Dose Response Modeling of Airways to Mitigate Radiation-Induced Airway Injury in Lung SAbR
    Samanta, S.
    Modiri, A.
    Rozario, T.
    Yu, J.
    Yan, Y.
    Timmerman, R. D.
    Sawant, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S6 - S6
  • [2] Dosimetric comparison of the two dose reporting modes of Acuros XB and AAA for lung SBRT
    Mampuya, A. W.
    Nakamura, M.
    Hirose, Y.
    Ishigaki, T.
    Mizowaki, T.
    Hiraoka, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S718 - S718
  • [3] Virtual Bronchoscopy-Guided IMRT Planning for Mapping and Avoiding Radiation Injury to the Airway Tree in Lung SAbR
    Sawant, A.
    Modiri, A.
    Bland, R.
    Yan, Y.
    Ahn, C.
    Timmerman, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3197 - 3197
  • [4] ADVANCED LUNG TREATMENT USING DIFFERENT MODALITIES: COMPARISON OF ACUROS XB AND AAA DOSE CALCULATIONS
    Fogliata, A.
    Clivio, A.
    Nicolini, G.
    de Palma, E. Vanetti
    Cozzi, L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S575 - S575
  • [5] Virtual Bronchoscopy-Guided Treatment Planning to Map and Mitigate Radiation-Induced Airway Injury in Lung SAbR
    Kazemzadeh, Narges
    Modiri, Arezoo
    Samanta, Santanu
    Yan, Yulong
    Bland, Ross
    Rozario, Timothy
    Wibowo, Henky
    Iyengar, Puneeth
    Ahn, Chul
    Timmerman, Robert
    Sawant, Amit
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (01): : 210 - 218
  • [6] Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans
    Petra S Kroon
    Sandra Hol
    Marion Essers
    Radiation Oncology, 8
  • [7] Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans
    Kroon, Petra S.
    Hol, Sandra
    Essers, Marion
    RADIATION ONCOLOGY, 2013, 8
  • [8] Virtual Bronchoscopy-Guided Risk-Management Based Treatment Planning to Mitigate Radiation-Induced Airway Injury in Lung SAbR
    Kazemzadeh, N.
    Modiri, A.
    Hamzeei, M.
    Hagan, A.
    Rozario, T.
    Yan, Y.
    Wibowo, H.
    Yu, J.
    Timmerman, R.
    Sawant, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 3258 - 3258
  • [9] Dosimetric Evaluation of Dose-To-Medium Vs. Dose-To-Water Using Acuros XB for Lung, Spine and Head-And-Neck Plans
    Yu, S.
    Rosenzweig, D.
    Pacella, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3559 - 3559
  • [10] BEST IN PHYSICS (THERAPY): Accounting for Respiration-Induced Motion of Peripheral Airways in Virtual Bronchoscopy-Guided Lung Stereotactic Ablative Radiotherapy Planning
    Vicente, E.
    Modiri, A.
    Yu, K.
    Wibowo, H.
    Yan, Y.
    Timmerman, R.
    Sawant, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E471 - E471