Inspection of pipelines using the first longitudinal guided wave mode

被引:28
|
作者
Lowe, P. S. [1 ,2 ]
Sanderson, R. [2 ]
Pedram, S. K. [1 ,2 ]
Boulgouris, N. V. [2 ]
Mudge, P. [2 ]
机构
[1] Brunel Univ, Kingston Lane, Uxbridge UB8 3PH, Middx, England
[2] TWI Ltd, Cambridge CB21 6AL, England
关键词
Pipeline inspection; finite element modeling; ultrasonic guided waves; compression transducers; pure excitation; PROPAGATION; SIGNAL;
D O I
10.1016/j.phpro.2015.08.079
中图分类号
O59 [应用物理学];
学科分类号
摘要
Inspection of cylindrical structures using the first longitudinal Ultrasonic Guided Wave (UGW) mode has so far been predominantly neglected. This is due to its attenuative and dispersive behaviour, at common UGW operating frequencies (20-100 kHz). However, with the current knowledge on the level of attenuation in the first longitudinal wave mode and dispersion compensation techniques, the first longitudinal guided wave mode no longer need to be neglected. Furthermore, the first longitudinal guided wave mode has higher number of non-axisymmetric modes compared to other axisymmetric modes in the operating frequency. This will enhance the flaw sizing capability which makes the first longitudinal guided wave mode a viable prospect for UGW inspection of cylindrical structures. This study has been performed to investigate the potential of exciting the first longitudinal guided wave mode in isolation. Numerical investigations have been conducted to investigate the pure excitation of the first longitudinal guided wave mode. It has been shown that the first longitudinal guided wave mode can be used in UGW inspection effectively in isolation by adopting transducers with out of plane vibration for excitation. This can reduces the cost and weight of UGW inspection tooling. Numerical results are empirically validated. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:338 / 342
页数:5
相关论文
共 50 条
  • [1] Inspection of Cylindrical Structures Using the First Longitudinal Guided Wave Mode in Isolation for Higher Flaw Sensitivity
    Lowe, Premesh Shehan
    Sanderson, Ruth M.
    Boulgouris, Nikolaos V.
    Haig, Alex G.
    Balachandran, Wamadeva
    IEEE SENSORS JOURNAL, 2016, 16 (03) : 706 - 714
  • [2] THE NUMBERICAL SIMULATION ON MAGNETOSTRICTIVE GUIDED WAVE FOR CRACKS INSPECTION IN PIPELINES
    Long, Shengrong
    Zhong, Yuning
    Song, Xiaochun
    Yang, Lingyu
    ADVANCES IN COMPUTING, CONTROL AND INDUSTRIAL ENGINEERING, 2012, 235 : 192 - +
  • [3] Defect Detection using Power Spectrum of Torsional Waves in Guided-Wave Inspection of Pipelines
    Mahal, Houman Nakhli
    Yang, Kai
    Nandi, Asoke K.
    APPLIED SCIENCES-BASEL, 2019, 9 (07):
  • [4] Mode selection of guided waves for ultrasonic inspection of gas pipelines with thick coating
    Pan, E
    Rogers, J
    Datta, SK
    Shah, AH
    MECHANICS OF MATERIALS, 1999, 31 (03) : 165 - 174
  • [5] Compressed Sensing Method for Health Monitoring of Pipelines Based on Guided Wave Inspection
    Wang, Zhe
    Huang, Songling
    Wang, Shen
    Zhuang, Shuangyong
    Wang, Qing
    Zhao, Wei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 4722 - 4731
  • [6] Long range guided wave inspection of pipelines by a new local magnetostrictive transducer
    Bertoncini, F.
    Raugi, M.
    Turcu, F.
    Acciani, G.
    Brunetti, G.
    Fornarelli, G.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 913 - +
  • [7] The choice of torsional or longitudinal excitation in guided wave pipe inspection
    Alleyne, D. N.
    Vogt, T.
    Cawley, P.
    INSIGHT, 2009, 51 (07) : 373 - 377
  • [8] Circumference Damage Identification in a pipe using Mode Conversion of Longitudinal Guided Wave
    Wu Jing
    Zhang Weiwei
    ADVANCED MATERIALS AND PROCESSES III, PTS 1 AND 2, 2013, 395-396 : 787 - 791
  • [9] The application of low frequency longitudinal guided wave mode for the inspection of multi-hole steel floral pipes
    Liu, Z. H.
    Xie, X. D.
    Wu, B.
    Li, Y. H.
    He, C. F.
    10TH ANGLO-FRENCH PHYSICAL ACOUSTICS CONFERENCE (AFPAC 2011), 2012, 353
  • [10] Wave-attenuation estimation in fluid-filled steel pipes: The first longitudinal guided wave mode
    Na, W. -B.
    Yoon, H. -S.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2007, 43 (08) : 549 - 554