Picomolar detection of hydrogen peroxide at glassy carbon electrode modified with NAD+ and single walled carbon nanotubes

被引:20
|
作者
Salimi, Abdollah [1 ,2 ]
Miranzadeh, Leyla [1 ]
Hallaj, Rahman [1 ]
Mamkhezri, Hussein [1 ]
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj, Iran
关键词
carbon nanotubes; NAD(+) oxidation product; H2O2; sensor; picomolar detection;
D O I
10.1002/elan.200804234
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potential cycling was used for oxidation of NAD(+) and producing an electroactive redox couple which strongly adsorbed on the electrode surface modified with single walled carbon nanotubes (SWCNTs). Modified electrode shows a pair of well defined and nearly reversible redox peaks at pH range 1 - 13 and the response showed a surf ace-controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of adsorbed redox couple onto CNTs films were about 6.32 x 10(-10)) mol cm(-2) and 2.0 (+/- 0.20) s(-1), respectively, indicating the high loading ability of CNTs toward the oxidation product of NAD(+) (2,8-dihydroxy adenine dinucleotide) and great facilitation of the electron transfer between redox couple and CNTs immobilized onto electrode surface. The modified electrode exhibited excellent electrocatalytic activity for H2O2 reduction at reduced overpotential. The catalytic rate constant for H2O2 reduction was found to be 2.22(+/- 0.20) x 10(4) M-1 s(-1). The catalytic reduction current allows the amperometric detection Of H2O2, at an applied potential of -0.25 V vs. Ag/AgCl with a detection limit of 10 pM and linear response up to 100 nM and resulting analytical sensitivity 747.6 nA/pM. The remarkably low detection limit (10 pM) is the lowest value ever reported for direct H2O2, determination on the electrodes at pH 7. The modified electrode can be used for monitoring H2O2 without the need for an enzyme or enzyme mimic. The proposed method for rapid amperometric detection of H2O2 is low cost and high throughput. Furthermore, the sensor can be used to any detection scheme that uses enzymatically generated H2O2 as a reactive product in biological systems.
引用
收藏
页码:1760 / 1768
页数:9
相关论文
共 50 条
  • [1] Electrocatalytic reduction of NAD+ at glassy carbon electrode modified with single-walled carbon nanotubes and Ru(III) complexes
    Abdollah Salimi
    Mohadeseh Izadi
    Rahman Hallaj
    Saied Soltanian
    Hassan Hadadzadeh
    Journal of Solid State Electrochemistry, 2009, 13 : 485 - 496
  • [2] Electrocatalytic reduction of NAD+ at glassy carbon electrode modified with single-walled carbon nanotubes and Ru(III) complexes
    Salimi, Abdollah
    Izadi, Mohadeseh
    Hallaj, Rahman
    Soltanian, Saied
    Hadadzadeh, Hassan
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (03) : 485 - 496
  • [3] Fabrication of Prussian Blue/Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode for Electrochemical Detection of Hydrogen Peroxide
    Farah, Abdullahi Mohamed
    Shooto, Ntaote David
    Thema, Force Tefo
    Modise, Johannes Sekomeng
    Dikio, Ezekiel Dixon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (05): : 4302 - 4313
  • [4] Electrocatalytic reduction of NAD+ at multi-walled carbon nanotubes modified electrode
    Chen, LM
    Ding, F
    Wang, H
    Zhang, W
    Lu, JX
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (04) : 427 - 430
  • [5] NAD+ hydrogenation on Au electrode deposited on modified glassy carbon
    Rahman, Gul
    Lim, Ji Yeon
    Jung, Kwang-Deog
    Joo, Oh-Shim
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (10) : 1371 - 1374
  • [6] Prussian Blue/Multi-walled carbon nanotubes composite films modified glassy carbon electrode for the determination of hydrogen peroxide
    Li Li-Hua
    Xu Qin
    Wang Hai-Yan
    Hu Xiao-Ya
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (06) : 835 - 838
  • [7] A novel non-enzymatic hydrogen peroxide sensor based on single walled carbon nanotubes-manganese complex modified glassy carbon electrode
    Salimi, Abdollah
    Mandioun, Monierosadat
    Noorbakhsh, Abdollah
    Abdolmaleki, Amir
    Ghavami, Raoof
    ELECTROCHIMICA ACTA, 2011, 56 (09) : 3387 - 3394
  • [8] Multi-walled Carbon Nanotubes-Modified Glassy Carbon Electrode for the Detection of Anthracene
    Mwazighe, Fredrick M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11058 - 11069
  • [9] A kinetic study of NAD+ reduction on a ruthenium modified glassy carbon electrode
    Man, F
    Omanovic, S
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 568 (1-2) : 301 - 313
  • [10] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235