Some simple rules for contrast, signal-to-noise and resolution in in-line x-ray phase-contrast imaging

被引:95
|
作者
Gureyev, Timur E. [1 ]
Nesterets, Yakov I. [1 ]
Stevenson, Andrew W. [1 ]
Miller, Peter R. [1 ]
Pogany, Andrew [1 ]
Wilkins, Stephen W. [1 ]
机构
[1] CSIRO Mat Sci & Engn, Clayton, Vic 3169, Australia
来源
OPTICS EXPRESS | 2008年 / 16卷 / 05期
关键词
D O I
10.1364/OE.16.003223
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Simple analytical expressions are derived for the spatial resolution, contrast and signal-to-noise in X-ray projection images of a generic phase edge. The obtained expressions take into account the maximum phase shift generated by the sample and the sharpness of the edge, as well as such parameters of the imaging set-up as the wavelength spectrum and the size of the incoherent source, the source-to-object and object-to-detector distances and the detector resolution. Different asymptotic behavior of the expressions in the cases of large and small Fresnel numbers is demonstrated. The analytical expressions are compared with the results of numerical simulations using Kirchhoff diffraction theory, as well as with experimental X-ray measurements. (c) 2008 Optical Society of America.
引用
收藏
页码:3223 / 3241
页数:19
相关论文
共 50 条
  • [1] Microbubbles as contrast agent for in-line x-ray phase-contrast imaging
    Xi, Yan
    Tang, Rongbiao
    Wang, Yujie
    Zhao, Jun
    APPLIED PHYSICS LETTERS, 2011, 99 (01)
  • [2] Experiment of in-line X-ray phase-contrast imaging
    Gong, Shao-Run
    Gao, Feng
    Xu, Ya-Jie
    Liu, Hong
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2010, 8 (01): : 63 - 69
  • [3] Influence of imaging geometry on noise texture in X-ray in-line phase-contrast imaging
    Chou, Cheng-Ying
    Anastasio, Mark A.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [4] Numerical Simulation of X-ray in-line Phase-contrast Imaging
    Gong Shao-run
    Gao Feng
    Zhou Zhong-xing
    Miao Hui
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 309 - 313
  • [5] Second order x-ray in-line phase-contrast imaging
    Cong, Wenxiang
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [6] Influence of imaging geometry on noise texture in quantitative in-line X-ray phase-contrast imaging
    Chou, Cheng-Ying
    Anastasio, Mark A.
    OPTICS EXPRESS, 2009, 17 (17): : 14466 - 14480
  • [7] Depth resolution properties of in-line X-ray phase-contrast tomosynthesis
    Guan, Huifeng
    Xu, Qiaofeng
    Garson, Alfred
    Anastasio, Mark A.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] On the optimization of experimental parameters for x-ray in-line phase-contrast imaging
    Nesterets, YI
    Wilkins, SW
    Gureyev, TE
    Pogany, A
    Stevenson, AW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09):
  • [9] Optimization of X-ray phase-contrast imaging based on in-line holography
    Wu, XZ
    Liu, H
    Yan, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 234 (04): : 563 - 572
  • [10] In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science
    Mayo, Sheridan C.
    Stevenson, Andrew W.
    Wilkins, Stephen W.
    MATERIALS, 2012, 5 (05) : 937 - 965