High-Sensitivity Electric Potential Sensors for Non-Contact Monitoring of Physiological Signals

被引:2
|
作者
Tang, Xinyao [1 ]
Chen, Wangbo [1 ]
Mandal, Soumyajit [1 ]
Bi, Kevin [2 ]
Ozdemir, Tayfun [2 ]
机构
[1] Case Western Reserve Univ, Dept Elect Comp & Syst Engn, Cleveland, OH 44106 USA
[2] Virtual EM Inc, Ann Arbor, MI 33174 USA
关键词
Capacitive ECG; electric potential sensor (EPS); non-contact cardiopulmonary sensing; non-contact EEG; non-contact spirometry; passive E-field sensing; HEART; SYSTEM; NIGHT; VARIABILITY; INTEGRATOR; AMPLIFIER; FLOW;
D O I
10.1109/ACCESS.2022.3150587
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper describes highly-sensitive passive electric potential sensors (EPS) for non-contact detection of multiple biophysical signals, including electrocardiogram (ECG), respiration cycle (RC), and electroencephalogram (EEG). The proposed EPS uses an optimized transimpedance amplifier (TIA), a single guarded sensing electrode, and an adaptive cancellation loop (ACL) to maximize sensitivity (DC transimpedance = 150 G Omega) in the presence of power line interference (PLI) and motion artifacts. Tests were performed on healthy adult volunteers in noisy and unshielded indoor environments. Useful sensing ranges for ECG, RC, and EEG measurements, as validated against reference contact sensors, were observed to be approximately 50 cm, 100 cm, and 5 cm, respectively. ECG and RC signals were also successfully measured through wooden tables for subjects in sleep-like postures. The EPS were integrated with a wireless microcontroller to realize wireless sensor nodes capable of streaming acquired data to a remote base station in real-time.
引用
收藏
页码:19096 / 19111
页数:16
相关论文
共 50 条
  • [1] NON-CONTACT OPTICAL PROFILOMETER WITH LINEARIZED RESPONSE AND HIGH-SENSITIVITY
    SHAMIR, J
    BRUNFELD, A
    TOKER, G
    NDT INTERNATIONAL, 1988, 21 (06): : 430 - 434
  • [2] Non-contact monitoring of kiwifruit ripening using a high-sensitivity multi-frequency inductive sensor
    Boukharouba, Hana
    Pasquier, Alexiane
    Le Diraison, Yohan
    Serfaty, Stephane
    Joubert, Pierre-Yves
    2023 IEEE SENSORS, 2023,
  • [3] High-sensitivity RGO-TiO2 humidity sensor driven by triboelectric nanogenerators for non-contact monitoring of human respiration
    Yu, Shuguo
    Zhang, Hongyan
    Zhang, Jun
    Hu, Ziyan
    JOURNAL OF ALLOYS AND COMPOUNDS, 2023, 935
  • [4] High-sensitivity QCM humidity sensor based on chitosan/ carboxymethylated multiwalled carbon nanotubes composite for non-contact respiratory monitoring
    Gao, Lingfei
    Li, Hao
    Dong, Xiangyang
    Li, Wei
    Deng, Hongbing
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 279
  • [5] Non-contact imaging of carbon composite structures using electric potential (displacement current) sensors
    Gebrial, W.
    Prance, R. J.
    Harland, C. J.
    Stiffell, P. B.
    Prance, H.
    Clark, T. D.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (06) : 1470 - 1476
  • [6] Non-Contact Measurement of Electric Potential of PV Modules
    Hishikawa, Yoshihiro
    Yamagoe, Kengo
    Onuma, T.
    2015 IEEE 42ND PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2015,
  • [7] Non-contact, laser-based monitoring of physiological activity
    Scalise, L.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 85 (03) : 312 - 312
  • [8] Depth profiling of defects in stainless steel using electric potential sensors and a non-contact AC potential drop method
    Prance, R.
    Gebrial, W.
    Antrobus, C.
    INSIGHT, 2008, 50 (02) : 95 - 97
  • [9] Application of non-contact sensors for health monitoring in hospitals: a narrative review
    Choo, Yoo Jin
    Lee, Gun Woo
    Moon, Jun Sung
    Chang, Min Cheol
    FRONTIERS IN MEDICINE, 2024, 11
  • [10] A non-contact flexible pyroelectric sensor for wireless physiological monitoring system
    Jian He
    Sen Li
    Xiaojuan Hou
    Yongjun Zhou
    Hao Li
    Min Cui
    Tao Guo
    Xiangdong Wang
    Jiliang Mu
    Wenping Geng
    Xiujian Chou
    Science China Information Sciences, 2022, 65