Modification to poloidal charge exchange recombination spectroscopy measurement in JT-60U tokamak

被引:0
|
作者
Ding Bo-Jiang [1 ]
Sakamoto Yoshiteru
Miura Yukitoshi
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[2] Japan Atom Energy Agcy, Naka, Ibaraki 3110193, Japan
来源
CHINESE PHYSICS | 2007年 / 16卷 / 11期
关键词
atomic process; charge exchange recombination spectroscopy (CXRS); modification; plasma;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
With consideration of the effects of the atomic process and the sight line direction on the charge exchange recombination spectroscopy (CXRS), a code used to modify the poloidal CXRS measurement on Tokamak-60 Upgrade (JT-60U) in Japan Atomic Energy Research Institute is developed, offering an effective tool to modify the measurement and analyse experimental results further. The results show that the poloidal velocity of ion is overestimated but the ion temperature is underestimated by the poloidal CXRS measurement, and they also indicate that the effect of observation angle on rotation velocity is a dominant one in a core region (r/a < 0.65), whereas in an edge region where the sight line is nearly normal to the neutral beam, the observation angle effect is very small. The difference between the modified velocity and the neoclassical velocity is not larger than the error in measurement. The difference inside the internal transport barrier (ITB) region is 2-3 times larger than that outside the ITB region, and it increases when the effect of excited components in neutral beam is taken into account. The radial electric field profile is affected greatly by the poloidal rotation term, which possibly indicates the correlation between the poloidal rotation and the transport barrier formation.
引用
收藏
页码:3434 / 3442
页数:9
相关论文
共 50 条
  • [1] Multichordal charge exchange recombination spectroscopy on the JT-60U tokamak
    Koide, Y
    Sakasai, A
    Sakamoto, Y
    Kubo, H
    Sugie, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 119 - 127
  • [2] Simulated correction to poloidal charge-exchange recombination spectroscopy measurement in a tokamak
    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China
    不详
    1600, 789-800 (June 1, 2005):
  • [3] Simulated correction to poloidal charge-exchange recombination spectroscopy measurement in a tokamak
    Ding, BJ
    Sakamoto, Y
    Miura, Y
    PLASMA PHYSICS AND CONTROLLED FUSION, 2005, 47 (06) : 789 - 800
  • [4] Recent progress in the JT-60U tokamak
    Nishitani, T
    18TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 1999, : 13 - 20
  • [5] Divertor diagnostics and physics in the JT-60U tokamak
    Sakasai, A
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 45 - 52
  • [6] Core correlation reflectometer at the JT-60U tokamak
    Shinohara, K
    Nazikian, R
    Fujita, T
    Yoshino, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4246 - 4250
  • [7] Divertor diagnostics and physics in the JT-60U tokamak
    Japan Atomic Energy Research Inst, Ibaraki, Japan
    Fusion Engineering and Design, 1997, 34-35 : 45 - 52
  • [8] Fast measurement of ion temperature using filter charge exchange recombination spectroscopy system towards real-time plasma control in JT-60U
    Yoshida, M.
    Kobayashi, S.
    Takenaga, H.
    Sakata, S.
    Kamada, Y.
    FUSION SCIENCE AND TECHNOLOGY, 2007, 51 (2T) : 301 - 303
  • [9] CHARGE-EXCHANGE NEUTRAL PARTICLE MEASUREMENT IN MEV ENERGY-RANGE ON JT-60U
    KUSAMA, Y
    NEMOTO, M
    SATOH, M
    TSUKAHARA, Y
    TOBITA, K
    TAKEUCHI, H
    PETROV, S
    AFANASSIEV, V
    KOZLOVSKIJ, S
    KISLYAKOV, A
    PETROV, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 339 - 341
  • [10] Development of completely solenoidless tokamak operation in JT-60U
    Ushigome, M
    Ide, S
    Itoh, S
    Jotaki, E
    Mitarai, O
    Shiraiwa, S
    Suzuki, T
    Takase, Y
    Tanaka, S
    Fujita, T
    Gohil, P
    Kamada, Y
    Lao, L
    Luce, T
    Miura, Y
    Naito, O
    Ozeki, T
    Politzer, P
    Sakamoto, Y
    NUCLEAR FUSION, 2006, 46 (02) : 207 - 213