An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features

被引:2
|
作者
Klein, Ran [1 ]
Razavi, Simin [2 ]
Memon, Rayhan [3 ]
Zuckier, Lionel S. [1 ]
机构
[1] Univ Ottawa, Div Nucl Med, Dept Med, Ottawa, ON, Canada
[2] Ottawa Hosp Res Inst, Ottawa, ON, Canada
[3] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
关键词
glomerular filtration rate; quality assurance; renal function; technetium-99m-diethylenetriaminepentaacetic acid; SLOPE-INTERCEPT MEASUREMENTS; RENAL-FUNCTION; CYSTATIN-C; CLEARANCE; EQUATION;
D O I
10.1097/MNM.0000000000000929
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Critical clinical decisions are made on the basis of the glomerular filtration rate (GFR) measured using technetium-99m-diethylenetriaminepentaacetic acid (DTPA) administration, followed by multiple time-point plasma sampling. As GFR studies rely on few data points and produce a single result, they are prone to technical errors that may remain inconspicuous. Objective We describe a data analysis worksheet that provides real-time quality control (QC) indicators and evaluate our initial clinical experience. Methods Two hundred and forty-six consecutive GFR studies carried out at our clinics were included. Our protocol used plasma samples at 2, 3, and 4 h after injection of technetium-99m-DTPA. Duplicate plasma samples, background samples, and aliquots of an activity dilution standard were counted. Times were logged for injection and dilution standard preparation, blood sampling, and counting. Data were entered into a custom GFR analysis spreadsheet that flagged QC in real time at warning and error levels, including QC of the expected ratio between dilution standard counts-activity ratio (CARs) measurements, which was newly introduced to our clinic. The prevalence of QC events was analyzed in three phases: baseline, training, and evaluation (n= 31, 69, and 146, respectively). Results From the baseline and training phases (n=100), CAR reference values were determined for each of two sites. In the absence of the CAR QC indicator, errors were present in 5/31 (16%) examinations, but with QC indication decreased to 7/146 (5%) (P< 0.05), suggesting that the real- time QC information guided the technologists to ensure proper standard preparation and sample handling, as intended. Improvements in other QC measures were also noted, resulting in an overall error rate reduction from 23 to 8%. Conclusion Real- time analysis of redundant information as a component of the GFR worksheet ensures quality results, but training of technologists and interpreting physicians is essential for optimal utilization of these QC indicators. Nucl Med Commun 40: 30- 40 Copyright (c) 2018 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:30 / 40
页数:11
相关论文
共 47 条
  • [1] Validation of the Glomerular Filtration Rate determination using Technetium-99m Diethylenetriaminepentaacetic acid instead of Chromium-51 Ethylenediaminetetraacetic acid
    Romero, I.
    Gil-Viciano, I.
    Fernandez-Romero, L.
    Notta, P.
    Rubio-Alvarez, L.
    Ysamat-Marfa, M.
    Munuera-Sanudo, C.
    Pineda-Fernandez, E.
    Bueno-Raspall, M.
    Gamez-Cenzano, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S508 - S509
  • [2] MIRD DOSE ESTIMATE REPORT NO 16 - RADIATION ABSORBED DOSE FROM TECHNETIUM-99M-DIETHYLENETRIAMINEPENTAACETIC ACID AEROSOL
    ATKINS, HL
    WEBER, DA
    SUSSKIND, H
    THOMAS, SR
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (09) : 1717 - 1719
  • [3] Comparative Evaluation of Glutamate-Sensitive Radiopharmaceuticals: Technetium-99m-Glutamic Acid and Technetium-99m-Diethylenetriaminepentaacetic Acid-bis(Glutamate) Conjugate for Tumor Imaging
    Kakkar, Dipti
    Tiwari, Anjani K.
    Chuttani, Krishna
    Kaul, Ankur
    Singh, Harpal
    Mishra, Anil K.
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2010, 25 (06) : 645 - 655
  • [4] TECHNETIUM-99M(V)-CITRATE COMPLEX FOR ESTIMATION OF GLOMERULAR FILTRATION RATE
    KOUNTZ, SL
    YEH, SH
    WOOD, J
    COHN, R
    KRISS, JP
    NATURE, 1967, 215 (5108) : 1397 - &
  • [5] MEASUREMENT OF GLOMERULAR-FILTRATION RATE USING TECHNETIUM-99M DTPA
    GINJAUME, M
    CASEY, M
    BARKER, F
    DUFFY, G
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (11) : 1347 - 1348
  • [6] EVALUATION OF A SINGLE INJECTION OF TC-99M-LABELED DIETHYLENETRIAMINEPENTAACETIC ACID FOR MEASURING GLOMERULAR-FILTRATION RATE IN HORSES
    WALSH, DM
    ROYAL, HD
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1992, 53 (05) : 776 - 780
  • [8] EVALUATION OF TC-99M-DIETHYLENETRIAMINEPENTAACETIC ACID NUCLEAR IMAGING FOR QUANTITATIVE-DETERMINATION OF THE GLOMERULAR-FILTRATION RATE OF DOGS
    KRAWIEC, DR
    BADERTSCHER, RR
    TWARDOCK, AR
    RUBIN, SI
    GELBERG, HB
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1986, 47 (10) : 2175 - 2179
  • [9] COMPARISON OF RADIONUCLIDE ESTIMATION OF GLOMERULAR-FILTRATION RATE USING TC-99M DIETHYLENETRIAMINEPENTAACETIC ACID AND CHROMIUM-51 ETHYLENEDIAMINETETRAACETIC ACID
    FLEMING, JS
    WILKINSON, J
    OLIVER, RM
    ACKERY, DM
    BLAKE, GM
    WALLER, DG
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (06): : 391 - 395
  • [10] MEASUREMENT OF GLOMERULAR-FILTRATION RATE IN CHILDREN USING TECHNETIUM-99M DIETHYLENETRIAMINE PENTA-ACETIC ACID
    AARONSON, IA
    MANN, MD
    SOUTH AFRICAN MEDICAL JOURNAL, 1985, 67 (13): : 507 - 509