Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects

被引:118
|
作者
Fellner, C
Pötter, R
Knocke, TH
Wambersie, A
机构
[1] Univ Vienna, Gen Hosp, Dept Radiotherapy & Radiobiol, A-1090 Vienna, Austria
[2] Univ Catholique Louvain, B-1200 Brussels, Belgium
关键词
three-dimensional treatment planning; cervix carcinoma; quality assurance; brachytherapy;
D O I
10.1016/S0167-8140(00)00282-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: A modern approach in treatment planning for cervix carcinoma is based on a series of computed tomography (CT) sections and 3D dose computation. When these techniques were not yet available, dose evaluation was based on orthogonal radiographs. The CT based planning provides information on target and organ volumes and dose-volume histograms. The radiography based planning provides only dimensions and doses at selected points. The aim of the presented study is to correlate the information obtained with the two approaches for high dose-rate (HDR) brachytherapy of cervix carcinoma. Methods: For the study 28 patients with 35 applications receiving HDR treatment with Ir-192 were investigated The planning system PLATO (Nucletron) was used. The different aspects of available data, results and inaccuracies regarding quality assurance were looked at. Results: From the CT based planning, the volume, location and dose-volume histograms were calculated for the CTV, rectum and bladder. From the radiography-based planning, the dose to point A (prescription), point B, rectum and bladder ICRU reference points [14], points related to the bony structures could be evaluated as well as volumes receiving different dose levels. These two sets of information were compared and following mean Values derived. For a dose prescription of 7 Gy at point A, as an average, 83% (44 cm(3)) of the clinical target volume (CTV) receives at least 7 Gy. The mean dose at the rectum ICRU reference point is 4.3 Gy, and 12% (9 cm(3)) of the rectum is encompassed by the 4.3 Gy isodose. The mean dose at the bladder ICRU reference point is 5.8 Gy, and 8% (16 cm(3)) of the bladder is encompassed by the 5.8 Gy isodose. The maximum dose to the rectum is 1.5 times higher than the dose at the ICRU reference point, and for the bladder 1.4 times higher. Uncertainties caused by the reconstruction of the applicator and merging of isodoses could be evaluated. Discussion: The subdivision of different approaches and the transfer from point doses to Volumes in treatment planning is possible and practical for the treatment of cervix carcinoma in brachytherapy. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 34 条
  • [1] Dosimetric Analysis of Computed Tomography-Based Brachytherapy Planning in Carcinoma Cervix
    Valiyaveettil, Deepthi
    Jilla, Swapna
    Ketham, Ramakrishna
    Reddy, P. Shivaram
    Nadendla, Beulah Elizabeth
    Manchala, Himani
    Malik, Monica
    SOUTH ASIAN JOURNAL OF CANCER, 2024,
  • [2] Clinical Outcomes of Computed Tomography-Based Volumetric Brachytherapy Planning for Cervical Cancer
    Simpson, Daniel R.
    Scanderbeg, Daniel J.
    Carmona, Ruben
    McMurtrie, Riley M.
    Einck, John
    Mell, Loren K.
    McHale, Michael T.
    Saenz, Cheryl C.
    Plaxe, Steven C.
    Harrison, Terry
    Mundt, Arno J.
    Yashar, Catheryn M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (01): : 150 - 157
  • [3] A new algorithm for autoreconstruction of catheters in computed tomography-based brachytherapy treatment planning
    Milickovic, N
    Baltas, D
    Giannouli, S
    Lahanas, M
    Zamboglou, N
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (03) : 372 - 383
  • [4] Computed Tomography-based Three-dimensional Image-guided Brachytherapy for Cancer of the Cervix Uteri
    Tse, R. P. Y.
    Siu, S. W. K.
    Chow, A.
    Chan, W.
    Tang, F.
    Ho, P.
    Leung, T. W.
    Kwong, P.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (04): : 224 - 229
  • [5] Comparison of orthogonal radiography and 3D CT-based treatment planning in HDR brachytherapy of cervix cancer
    Alezra, D.
    Rabin, T.
    Levin, D.
    Menchel, J.
    Symon, Z.
    Pfeffer, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S323 - S323
  • [6] Comparison of orthogonal radiography and 3D CT-based treatment planning in HDR brachytherapy of cervix cancer
    Alezra, D.
    Rabin, T.
    Levine, D.
    Menhel, J.
    Symon, Z.
    Pfeffer, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S407 - S408
  • [7] Early Outcomes and Dose-Volume Analysis for Patients With Cervical Cancer Treated With Computed Tomography-Based Treatment Planning in Brachytherapy
    Kawashima, A.
    Isohashi, F.
    Mabuchi, S.
    Okubo, H.
    Tamari, K.
    Seo, Y.
    Suzuki, O.
    Yoshioka, Y.
    Kimura, T.
    Ogawa, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E314 - E315
  • [8] Computed tomography-based treatment planning for high dose-rate brachytherapy of soft-tissue sarcoma
    Harrington, PJ
    Fung, AY
    Cohen, GN
    Alektlar, KM
    Zaider, M
    RADIOLOGY, 2001, 221 : 373 - 373
  • [9] Comparison of clinical outcome between computed tomography-based image-guided brachytherapy and two-dimensional-based brachytherapy for cervical cancer
    Imano, Nobuki
    Wadasaki, Koichi
    Nishibuchi, Ikuno
    Nagata, Yasushi
    GYNECOLOGIC ONCOLOGY REPORTS, 2019, 29 : 79 - 82
  • [10] End-to-end delivery quality assurance of computed tomography-based high-dose-rate brachytherapy using a gel dosimeter
    Tachibana, Hidenobu
    Watanabe, Yusuke
    Mizukami, Shinya
    Maeyama, Takuya
    Terazaki, Tsuyoshi
    Uehara, Ryuzo
    Akimoto, Tetsuo
    BRACHYTHERAPY, 2020, 19 (03) : 362 - 371