High Versus Low Implant Insertion Torque: A Histologic, Histomorphometric, and Biomechanical Study in the Sheep Mandible

被引:0
|
作者
Trisi, Paolo [1 ]
Todisco, Marzio
Consolo, Ugo [2 ]
Travaglini, Domenico
机构
[1] Biomat Clin Res Assoc, Lucca, Italy
[2] Univ Modena & Reggio Emilia, Sect Dent & Maxillofacial Surg, Dept Neurosci, Modena, Italy
关键词
biomechanics; bone compression; dental implants; histology; insertion torque; primary stability; RESONANCE FREQUENCY-ANALYSIS; TITANIUM IMPLANTS; DENTAL IMPLANTS; REMOVAL TORQUE; STABILITY; CADAVERS; SURFACE; RAT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to analyze, in an animal model, the histologic and biomechanical phenomena at the bone-implant interface of implants inserted with high torque (HT) as compared to low torque (LT) during the first 6 weeks of healing. Materials and Methods: Forty tapered-screw-form implants were placed in five hybrid sheep. The implant sites were placed in the mandible, using an extraoral approach; four were placed with HT (test: mean 110 Ncm) on one side and four were placed with LT (control: mean 10 Ncm) on the contralateral side. After 1, 2, 3, 4, and 6 weeks of healing, removal torque testing and resonance frequency analysis were performed and the animals were sacrificed for histologic examination. Results: Implants from the HT group showed significantly higher bone apposition than implants from the LT group at all examined healing times. Similarly, removal torque was consistently higher for the HT as compared to the LT group. A significant loss of primary stability in the HT group was evident 7 days after placement. Implants from the LT group achieved a significant increase in stability after 4 weeks. Resonance frequency analysis was unable to detect these histologic and biomechanical modifications of the bone-implant complex. Conclusions: The results of the study showed that high implant insertion torque in dense cortical bone does not induce bone necrosis or implant failure, but it does increase the primary stability of implants, which is extremely important in immediate loading protocols. Int J Oral Maxillofac Implants 2011;26:837-849
引用
收藏
页码:837 / 849
页数:13
相关论文
共 50 条
  • [1] Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing
    Consolo, Ugo
    Travaglini, Domenico
    Todisco, Marzio
    Trisi, Paolo
    Galli, Silvia
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) : 860 - 865
  • [2] Thermal oxidation and hydrofluoric acid treatment on the sandblasted implant surface: A histologic histomorphometric and biomechanical study
    Qamheya, Ala Hassan A.
    Arisan, Volkan
    Mutlu, Zihni
    Karabagli, Murat
    Tekkesin, Merva Soluk
    Kara, Kamuran
    Erol, Ayse
    Ersanli, Selim
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (07) : 741 - 755
  • [3] The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses
    Berardini, Marco
    Trisi, Paolo
    Sinjari, Bruna
    Rutjes, Anne W. S.
    Caputi, Sergio
    IMPLANT DENTISTRY, 2016, 25 (04) : 532 - 540
  • [4] HISTOLOGIC AND HISTOMORPHOMETRIC EVALUATION OF A HYDROPHILIC BLASTED AND ACID-ETCHED IMPLANT: AN EXPERIMENTAL STUDY IN SHEEP TIBIA
    Abdel-Haq, Jawad
    Karabuda, Z. Cuneyt
    Arisan, Volkan
    Mutlu, Zihni
    Kurkcu, Mehmet
    JOURNAL OF ISTANBUL UNIVERSITY FACULTY OF DENTISTRY, 2010, 44 (03) : 141 - 152
  • [5] Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. An experimental study in sheep
    Lahens, Bradley
    Neiva, Rodrigo
    Tovar, Nick
    Alifarag, Adham M.
    Jimbo, Ryo
    Bonfante, Estevam A.
    Bowers, Michelle M.
    Cuppini, Marla
    Freitas, Helora
    Witek, Lukasz
    Coelho, Paulo G.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 63 : 56 - 65
  • [6] Biomechanical Evaluation of Resistance to Insertion Torque of Different Implant Systems and Insertion Driver Types
    Nary Filho, Hugo
    Calvo Guirado, Jose Luis
    Matsumoto, Mariza Akemi
    Bresaola, Marco Dapievi
    Aur, Roberto
    IMPLANT DENTISTRY, 2015, 24 (02) : 211 - 216
  • [7] Resonance Frequency Analysis, Insertion Torque, and Bone to Implant Contact of 4 Implant Surfaces: Comparison and Correlation Study in Sheep
    Dagher, Maroun
    Mokbel, Nadim
    Jabbour, Gabriel
    Naaman, Nada
    IMPLANT DENTISTRY, 2014, 23 (06) : 672 - 678
  • [8] Boron- and Boric Acid-Treated Titanium Implant Surfaces in Sheep Tibia: A Histologic, Histomorphometric and Mechanical Study
    Aysesek, Nazli
    Arisan, Volkan
    Balcioglu, Niluefer Boeluekbasi
    Erol, Ayse
    Kuruoglu, Furkan
    Tekkesin, Merva Soluk
    Ersanli, Selim
    BIOENGINEERING-BASEL, 2022, 9 (11):
  • [9] Assessment of Relationships Between Implant Insertion Torque and Cortical Shape of the Mandible Using Panoramic Radiography: Preliminary Study
    Tsukioka, Tsuneyuki
    Sasaki, Yusuke
    Kaneda, Takashi
    Buch, Karen
    Sakai, Osamu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 622 - 626
  • [10] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830