Semi-automated Detection of the Timing of Respiratory Muscle Activity: Validation and First Application

被引:8
|
作者
Rodrigues, Antenor [1 ]
Janssens, Luc [2 ,3 ]
Langer, Daniel [3 ,4 ]
Matsumura, Umi [5 ]
Rozenberg, Dmitry [6 ,7 ]
Brochard, Laurent [1 ,8 ,9 ]
Reid, W. Darlene [8 ,10 ,11 ]
机构
[1] St Michaels Hosp, Dept Crit Care, Toronto, ON, Canada
[2] Katholieke Univ Leuven, Fac Engn Technol, Dept Elect Engn, Leuven, Belgium
[3] Katholieke Univ Leuven, Res Grp Rehabil Internal Disorders, Fac Movement & Rehabil Sci, Dept Rehabil Sci, Leuven, Belgium
[4] Univ Hosp Leuven, Resp Rehabil & Resp Div, Leuven, Belgium
[5] Nagasaki Univ, Dept Physiotherapy, Nagasaki, Japan
[6] Univ Toronto, Univ Hlth Network, Temerty Fac Med, Div Respirol, Toronto, ON, Canada
[7] Toronto Gen Hosp, Res Inst, Toronto, ON, Canada
[8] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[9] St Michaels Hosp, Li Ka Shing Knowledge Inst, Keenan Res Ctr, Toronto, ON, Canada
[10] Univ Toronto, Dept Phys Therapy, Toronto, ON, Canada
[11] Univ Hlth Network, Toronto Rehabil Inst, KITE, Toronto, ON, Canada
关键词
respiratory muscles; ventilatory muscles; electromyography; surface electromyography; neck muscles; INTERCOSTAL; DRIVE; ELECTROMYOGRAPHY; MOTONEURONS; DIAPHRAGM; VOLUNTARY;
D O I
10.3389/fphys.2021.794598
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: Respiratory muscle electromyography (EMG) can identify whether a muscle is activated, its activation amplitude, and timing. Most studies have focused on the activation amplitude, while differences in timing and duration of activity have been less investigated. Detection of the timing of respiratory muscle activity is typically based on the visual inspection of the EMG signal. This method is time-consuming and prone to subjective interpretation.Aims: Our main objective was to develop and validate a method to assess the respective timing of different respiratory muscle activity in an objective and semi-automated manner.Method: Seven healthy adults performed an inspiratory threshold loading (ITL) test at 50% of their maximum inspiratory pressure until task failure. Surface EMG recordings of the costal diaphragm/intercostals, scalene, parasternal intercostals, and sternocleidomastoid were obtained during ITL. We developed a semi-automated algorithm to detect the onset (EMG, onset) and offset (EMG, offset) of each muscle's EMG activity breath-by-breath with millisecond accuracy and compared its performance with manual evaluations from two independent assessors. For each muscle, the Intraclass Coefficient correlation (ICC) of the EMG, onset detection was determined between the two assessors and between the algorithm and each assessor. Additionally, we explored muscle differences in the EMG, onset, and EMG, offset timing, and duration of activity throughout the ITL.Results: More than 2000 EMG, onset s were analyzed for algorithm validation. ICCs ranged from 0.75-0.90 between assessor 1 and 2, 0.68-0.96 between assessor 1 and the algorithm, and 0.75-0.91 between assessor 2 and the algorithm (p < 0.01 for all). The lowest ICC was shown for the diaphragm/intercostal and the highest for the parasternal intercostal (0.68 and 0.96, respectively). During ITL, diaphragm/intercostal EMG, onset occurred later during the inspiratory cycle and its activity duration was shorter than the scalene, parasternal intercostal, and sternocleidomastoid (p < 0.01). EMG, offset occurred synchronously across all muscles (p >= 0.98). EMG, onset, and EMG, offset timing, and activity duration was consistent throughout the ITL for all muscles (p > 0.63).Conclusion: We developed an algorithm to detect EMG, onset of several respiratory muscles with millisecond accuracy that is time-efficient and validated against manual measures. Compared to the inherent bias of manual measures, the algorithm enhances objectivity and provides a strong standard for determining the respiratory muscle EMG, onset.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
    Rodrigues, Antenor
    Janssens, Luc
    Langer, Daniel
    Matsumura, Umi
    Rozenberg, Dmitry
    Brochard, Laurent
    Reid, W. Darlene
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2025, (215):
  • [2] Validation of a New Semi-Automated Technique to Evaluate Muscle Capillarization
    Ballak, Sam B.
    Yap, Moi H.
    Harding, Peter J.
    Degens, Hans
    OXYGEN TRANSPORT TO TISSUE XXXVII, 2016, 876 : 87 - 93
  • [3] Validation of a Semi-Automated Workstation for Immunohematology
    Person, R. M.
    Muniz, J. G.
    Carvalho, F. O.
    Ribeiro, J. P.
    Barreto, J.
    TRANSFUSION, 2010, 50 : 161A - 162A
  • [4] A SEMI-AUTOMATED MICROASSAY FOR COMPLEMENT ACTIVITY
    LIU, CC
    YOUNG, JDE
    JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 114 (1-2) : 33 - 39
  • [5] Semi-automated System for Pothole Detection and Location
    Nunez, Favell
    Espinal, Rodrigo
    Zavala, Gerardo
    Banegas, Josue
    24TH INTERNATIONAL CONFERENCE ON ENGINEERING APPLICATIONS OF NEURAL NETWORKS, EAAAI/EANN 2023, 2023, 1826 : 607 - 618
  • [6] Semi-automated initialization of simulations: an application to healthcare
    Padilla, Jose J.
    Diallo, Saikou Y.
    Kavak, Hamdi
    Sahin, Olcay
    Sokolowski, John A.
    Gore, Ross J.
    JOURNAL OF DEFENSE MODELING AND SIMULATION-APPLICATIONS METHODOLOGY TECHNOLOGY-JDMS, 2016, 13 (02): : 171 - 182
  • [7] Observer performance in semi-automated microbleed detection
    Kuijf, Hugo J.
    Brundel, Manon
    de Bresser, Jeroen
    Viergever, Max A.
    Biessels, Geert Jan
    Geerlings, Mirjam I.
    Vincken, Koen L.
    MEDICAL IMAGING 2013: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2013, 8673
  • [8] In vivo validation of a novel semi-automated method for border detection in intravascular ultrasound images
    Bourantas, CV
    Plissiti, ME
    Fotiadis, DI
    Protopappas, VC
    Mpozios, GV
    Katsouras, CS
    Kourtis, IC
    Rees, MR
    Michalis, LK
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926): : 122 - 129
  • [9] Technical note on the validation of a semi-automated image analysis software application for estrogen and progesterone receptor detection in breast cancer
    Laszlo Krecsak
    Tamas Micsik
    Gabor Kiszler
    Tibor Krenacs
    Daniel Szabo
    Viktor Jonas
    Gergely Csaszar
    Laszlo Czuni
    Peter Gurzo
    Levente Ficsor
    Bela Molnar
    DIAGNOSTIC PATHOLOGY, 2011, 6
  • [10] Technical note on the validation of a semi-automated image analysis software application for estrogen and progesterone receptor detection in breast cancer
    László Krecsák
    Tamás Micsik
    Gábor Kiszler
    Tibor Krenács
    Dániel Szabó
    Viktor Jónás
    Gergely Császár
    László Czuni
    Péter Gurzó
    Levente Ficsor
    Béla Molnár
    Diagnostic Pathology, 6