The precision improvement of the scanner in optical scanning imaging system

被引:4
|
作者
Xiang, JY [1 ]
Wu, Z [1 ]
Zhang, P [1 ]
Huang, DX [1 ]
Wei, GS [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Optoelect Engn, Wuhan 430074, Peoples R China
来源
OPTICS AND LASER TECHNOLOGY | 1998年 / 30卷 / 02期
关键词
scanning imaging; galvanometer; step motor; pixel clock; pincushion distortion;
D O I
10.1016/S0030-3992(98)00023-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A disadvantage of using a galvanometer as the horizontal scanner in CSOM and OCT is its nonlinear distortion caused by the rotational inertial. This is inevitable even if a closed loop is equipped. Here, a second closed loop is introduced to provide pixel clocks to reduce the pincushion distortion of the images. A subdivided step motor is employed to be the vertical scanner as the result of price consideration. Nonetheless, the conventional linearity model of the peck torque with a winding current relationship is no longer in agreement with the experiment when the winding current is low, while a parabolic model is more likely to be reasonable. Relational treatment is proposed in the paper. Both methods have proved to be good enough to meet the requirement of a super resolution scanning imaging. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 50 条
  • [1] Precision analysis of scanning element in laser scanning and imaging system
    Xu, M
    Hu, JS
    Wu, X
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING II, 2005, 5633 : 315 - 320
  • [2] TWO-DIMENSIONAL SCANNER FOR SATELLITE SCANNING OPTICAL-SYSTEM
    SURGOICHEV, SI
    DOKLADI NA BOLGARSKATA AKADEMIYA NA NAUKITE, 1985, 38 (12): : 1649 - 1652
  • [3] PRECISION OPTICAL SCANNER FOR OPERATION IN A SEVERE ENVIRONMENT
    REICH, S
    BRILL, H
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 299 : 133 - 143
  • [4] A novel optical scanning system for breast cancer imaging
    Cheng, X
    Xu, X
    Zhou, S
    Wang, L
    Hu, B
    Li, F
    Wang, M
    Zhou, C
    Li, H
    Zhang, H
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION THERAPEUTICS, AND SYSTEMS XI, 2001, 4244 : 468 - 473
  • [5] IMAGING PROPERTIES OF AXICON IN A SCANNING OPTICAL-SYSTEM
    ARIMOTO, R
    SALOMA, C
    TANAKA, T
    KAWATA, S
    APPLIED OPTICS, 1992, 31 (31): : 6653 - 6657
  • [6] Concentric circle scanning system for largearea and high-precision imaging
    Laboratory for Manufacturing and Productivity, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge
    MA
    02139, United States
    Opt. Express, 15 (20014-20029):
  • [7] LIMITING PRECISION IN A SCANNING OPTICAL INTERFEROMETER
    HILL, RM
    BRUCE, CF
    AUSTRALIAN JOURNAL OF PHYSICS, 1962, 15 (02): : 194 - &
  • [8] High-precision scanner control system
    Yanagita, Y.
    Aoki, K.
    Kurii, T.
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XIV, 2010, 7826
  • [9] An optical measurement system for high precision alignment of imaging detectors
    Zeng, X. Chang
    Guan, W.
    Zhao, J.
    Huang, P.
    Wang, Z. Qiang
    Zhang, S.
    Zuo, X. Zhou
    Xi, G. Yang
    Yu, B. Wei
    Zhang, W. Ping
    Wang, Z. Li
    Zhang, X.
    Lv, X. Lian
    Yuan, W. Zheng
    Wang, X. Xiao
    He, Y.
    OPTICAL DESIGN AND TESTING XIII, 2023, 12765
  • [10] Precision improvement in frequency-scanning interferometry based on suppressing nonlinear optical frequency sweeping
    Deng, Zhongwen
    Liu, Zhigang
    Li, Bing
    Liu, Zhe
    OPTICAL REVIEW, 2015, 22 (05) : 724 - 730