Effect of design and operational conditions on the performance of subsurface flow treatment wetlands: Emerging organic contaminants as indicators

被引:94
|
作者
Kahl, Stefanie [1 ]
Nivala, Jaime [2 ]
van Afferden, Manfred [2 ]
Mueller, Roland A. [2 ]
Reemtsma, Thorsten [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Analyt Chem, Permoserstr 15, D-04318 Leipzig, Germany
[2] UFZ Helmholtz Ctr Environm Res, Ctr Environm Biotechnol UBZ, Permoserstr 15, D-04318 Leipzig, Germany
关键词
Constructed wetland; Domestic wastewater; Intensification; Micropollutants; Reciprocating wetland; Seasonality; WASTE-WATER TREATMENT; PERSONAL CARE PRODUCTS; CONSTRUCTED WETLANDS; MICROPOLLUTANT REMOVAL; URBAN WASTEWATERS; ACTIVATED-SLUDGE; SEWAGE-TREATMENT; TREATMENT PLANTS; PHARMACEUTICALS; MUNICIPAL;
D O I
10.1016/j.watres.2017.09.004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Six pilot-scale subsurface flow treatment wetlands loaded with primary treated municipal wastewater were monitored over one year for classical wastewater parameters and a set of emerging organic compounds (ECOs) serving as process indicators for biodegradation: caffeine, ibuprofen, naproxen, benzotriazole, diclofenac, acesulfame, and carbamazepine. The wetland technologies investigated included conventional horizontal flow, unsaturated vertical flow (single and two-stage), horizontal flow with aeration, vertical flow with aeration, and reciprocating. Treatment efficiency for classical wastewater parameters and EOCs generally increased with increasing design complexity and dissolved oxygen concentrations. The two aerated wetlands and the two-stage vertical flow system showed the highest EOC removal, and the best performance in warm season and most robust performance in the cold season. These three systems performed better than the adjacent conventional WWTP with respect to EOC removal. Acesulfame was observed to be removed (>90%) by intensified wetland systems and with use of a tertiary treatment sand filter during the warm season. Elevated temperature and high oxygen content (aerobic conditions) proved beneficial for EOC removal. For EOCs of moderate to low biodegradability, the co-occurrence of aerobic conditions and low content of readily available carbon appears essential for efficient removal. Such conditions occurred in the aerated systems and with use of a tertiary treatment sand filter. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:490 / 500
页数:11
相关论文
共 50 条
  • [1] The anaerobic biodegradation of emerging organic contaminants by horizontal subsurface flow constructed wetlands
    Ilyas, H.
    Masih, I.
    van Hullebusch, E. D.
    WATER SCIENCE AND TECHNOLOGY, 2021, 83 (11) : 2809 - 2828
  • [2] Prediction of the removal efficiency of emerging organic contaminants based on design and operational parameters of constructed wetlands
    Ilyas, Huma
    Masih, Ilyas
    van Hullebusch, Eric D.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (01):
  • [3] Comparison of operational design criteria for subsurface flow constructed wetlands for wastewater treatment
    Leonard, KM
    Swanson, GW
    WATER SCIENCE AND TECHNOLOGY, 2001, 43 (11) : 301 - 307
  • [4] Emerging organic contaminant removal depending on primary treatment and operational strategy in horizontal subsurface flow constructed wetlands: Influence of redox
    Avila, Cristina
    Reyes, Carolina
    Maria Bayona, Josep
    Garcia, Joan
    WATER RESEARCH, 2013, 47 (01) : 315 - 325
  • [5] Dynamics of emerging organic contaminant removal in conventional and intensified subsurface flow treatment wetlands
    Nivala, Jaime
    Kahl, Stefanie
    Boog, Johannes
    van Afferden, Manfred
    Reemtsma, Thorsten
    Mueller, Roland A.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 649 : 1144 - 1156
  • [6] Emerging organic contaminants in vertical subsurface flow constructed wetlands: Influence of media size, loading frequency and use of active aeration
    Avila, Cristina
    Nivala, Jaime
    Olsson, Linda
    Kassa, Kinfe
    Headley, Tom
    Mueller, Roland A.
    Maria Bayona, Josep
    Garcia, Joan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 494 : 211 - 217
  • [7] Design and performance of integrated subsurface flow wetlands in a cold climate
    Mæhlum, T
    Jenssen, PD
    CONSTRUCTED WETLANDS FOR WASTEWATER TREATMENT IN COLD CLIMATES, 2003, 11 : 69 - 86
  • [8] Effect of operational and design parameters on performance of pilot-scale horizontal subsurface flow constructed wetlands treating university campus wastewater
    Papaevangelou, Vassiliki
    Gikas, Georgios D.
    Tsihrintzis, Vassilios A.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (19) : 19504 - 19519
  • [9] Effect of operational and design parameters on performance of pilot-scale horizontal subsurface flow constructed wetlands treating university campus wastewater
    Vassiliki Papaevangelou
    Georgios D. Gikas
    Vassilios A. Tsihrintzis
    Environmental Science and Pollution Research, 2016, 23 : 19504 - 19519
  • [10] A decision tree framework to support design, operation, and performance assessment of constructed wetlands for the removal of emerging organic contaminants
    Ilyas, Huma
    Masih, Ilyas
    van Hullebusch, Eric D.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 760