Miniaturization of a biomedical gas sensor

被引:13
|
作者
Mirtaheri, P [1 ]
Omtveit, T
Klotzbuecher, T
Grimnes, S
Martinsen, OG
Tonnessen, TI
机构
[1] Rikshosp Univ Hosp, Intervent Ctr, N-0027 Oslo, Norway
[2] Univ Oslo, Dept Phys, N-1048 Blindern, Norway
[3] Rikshosp Univ Hosp, Dept Clin Engn, Oslo, Norway
[4] Alertis Med AS, Oslo, Norway
[5] Inst Mikrotech Mainz GMBH, Dept Opt, Mainz, Germany
[6] Rikshosp Univ Hosp, Dept Anesthesiol, Oslo, Norway
关键词
conductivity; ischemia; miniaturization; PCO2; sensor;
D O I
10.1088/0967-3334/25/6/015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In a previous study, we concluded that a conductivity based PCO2 sensor is an attractive solution for early detection of ischemia and presented two design geometries. For organ surface measurements, the planar design was suitable but it was difficult to insert the sensor into the tissue. A cylindrical design solution was favored for insertion due to the large membrane contact area and easy placement in a medical catheter. Since the previous cylindrical prototype was large and could damage the tissue, a more miniaturized sensor was needed. In the current paper, we present a miniaturized sensor with an outer diameter of 1 mm. The applied technology for manufacturing the sensor was a combination of mechanical turning, excimer laser drilling and conventional molding technique. The materials applied were PEEK (polyetherether ketone), PI (polyimide) with gold layers and polysiloxane. The membrane had to be gas permeable while acting as a barrier for ion transport, and was made of polysiloxane and had a thickness of 100-150 mum. The miniaturized sensor was tested for calibration, response time, drifting and pressure sensitivity. The results show that the miniaturized PCO2 sensor is capable of rapid and stable measurements both in vitro and ex vivo. The result from this study will be applied for the industrial manufacturing of such a biomedical sensor as a clinical product.
引用
收藏
页码:1511 / 1522
页数:12
相关论文
共 50 条
  • [1] The Development of Miniaturization Infrared Exhaust Gas Sensor
    Chen, Hongyan
    Zhang, Bing
    Li, Zhibin
    Liu, Wenzhen
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLIED MECHANICS, MECHATRONICS AND INTELLIGENT SYSTEMS (AMMIS2015), 2016, : 205 - 211
  • [2] Miniaturization of biomedical micromachines
    Dario, P
    Menciassi, A
    Stefanini, C
    Accoto, D
    2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, : 291 - 296
  • [3] Quantum sensor miniaturization
    Gilbert, G.
    Hamrick, M.
    Weinstein, Y. S.
    Pappas, S. P.
    Donadio, A.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2007, 19 (21-24) : 1798 - 1800
  • [4] The miniaturization of gas detection
    Hairston, D
    CHEMICAL ENGINEERING, 2005, 112 (01) : 19 - 21
  • [5] Miniaturization Effects on Implantable Antennas for Biomedical Applications
    Garcia-Miquel, A.
    Vidal, N.
    Lopez-Villegas, J. M.
    Sieiro, J. J.
    Ramos, F. M.
    2015 9th European Conference on Antennas and Propagation (EuCAP), 2015,
  • [6] Miniaturization of Dielectric Resonator Antenna for Biomedical communication
    Iqbal, Mian Shahzad
    Esselle, Karu P.
    Ge, Yuehe
    2013 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2013, : 1904 - +
  • [7] Quantum Sensor Miniaturization Prospectus
    Gilbert, G.
    Hamrick, M.
    Weinstein, Y. S.
    Pappas, S. P.
    Donadio, A.
    QUANTUM INFORMATION AND COMPUTATION VII, 2009, 7342
  • [8] Combination of Material Processing and Characterization Methods for Miniaturization of Field-Effect Gas Sensor
    Samotaev, Nikolay
    Litvinov, Artur
    Oblov, Konstantin
    Etrekova, Maya
    Podlepetsky, Boris
    Dzhumaev, Pavel
    SENSORS, 2023, 23 (01)
  • [9] Nanoparticle Optical Sensor Arrays: Gas Sensing and Biomedical Diagnosis
    Lu, Xiaohui
    Suslick, Kenneth S.
    Li, Zheng
    ANALYSIS & SENSING, 2023, 3 (02):
  • [10] Miniaturization of enantioselective gas chromatography
    Schurig, V
    Czesla, H
    ENANTIOMER, 2001, 6 (2-3): : 107 - 128