Purification of triolein for use in semipermeable membrane devices (SPMDs)

被引:22
|
作者
Lebo, JA
Almeida, FV
Cranor, WL
Petty, JD
Huckins, JN
Rastall, A
Alvarez, DA
Mogensen, BB
Johnson, BT
机构
[1] USGS, CERC, Columbia, MO 65201 USA
[2] Univ Estadual Campinas, Inst Quim, Campinas, SP, Brazil
[3] Chem Lab, Inst Hyg, INF 324, Heidelberg, Germany
[4] Natl Environm Res Inst, Dept Environm Chem, DK-4000 Roskilde, Denmark
关键词
oleic acid; methyl oleate; dialysis; purification; Microtox; yeast estrogen screen; YES;
D O I
10.1016/j.chemosphere.2003.09.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Analyses of triolein-containing semipermeable membrane devices (SPMDs) have sometimes been impeded by interferences caused by impurities endemic to triolein that codialyze with the analytes. Oleic acid and methyl oleate have been the most troublesome of these impurities because of their relatively high concentrations in triolein and because significant residues of both can persist even after size exclusion chromatographic (SEC) fractionation. These residues have also been blamed for false-positive signals during bioindicator testing of SPMD dialysates. To prevent these problems, a simple, cost-effective procedure was developed for purifying triolein destined for use in SPMDs: the bulk triolein is repeatedly (6x) partitioned against methanol. Tests of the procedure show that C-14-oleic acid is completely removed from the triolein. After SEC fractionation, dialysates of standard-size SPMDs made with the purified triolein contain less than 5 mug of methyl oleate as compared to sometimes more than 500 mug for dialysates (also after SEC) of SPMDs made with unpurified triolein. Gas chromatographic analyses with flame ionization and electron capture detection show that the purification treatment also greatly reduces the number and size of peaks caused by unidentified contaminants in the triolein. Microtox basic assay of dialysates of SPMDs shows that those made with the purified triolein have lower acute toxicities than dialysates of SPMDs made with unpurified triolein. Yeast estrogen screen (YES) testing of SPMDs fabricated with unpurified and purified triolein demonstrates that the purification process removes all background estrogenic activity. Published by Elsevier Ltd.
引用
收藏
页码:1217 / 1224
页数:8
相关论文
共 50 条
  • [1] Use of semipermeable membrane devices (SPMDs) for the calibration of tributyltin uptake rates in water.
    Schibetta, RC
    Manock, JJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U642 - U642
  • [2] Effects of acid/abandoned mine drainage on semipermeable membrane devices (SPMDs)
    McElroy, Nathan R.
    Lewis, Carol
    Devlin, Amy
    Opayemi, Fowosopefoluwa
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [3] APPLICATION OF SEMIPERMEABLE-MEMBRANE DEVICES (SPMDS) AS PASSIVE AIR SAMPLERS
    PETTY, JD
    HUCKINS, JN
    ZAJICEK, JL
    CHEMOSPHERE, 1993, 27 (09) : 1609 - 1624
  • [4] Prediction of PCB content in sportfish using semipermeable membrane devices (SPMDs)
    Shim, SM
    Santerre, CR
    Dorworth, LE
    Miller, BK
    Stahl, JR
    Deardorff, DC
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2004, 39 (02) : 263 - 271
  • [5] Use of semipermeable membrane devices (SPMDs) to characterize dissolved hydrocarbon fractions of both dispersed and undispersed oil
    Van Scoy, April R.
    Voorhees, Jennifer
    Anderson, Brian S.
    Philips, Bryn M.
    Tjeerdema, Ronald S.
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2013, 15 (11) : 2016 - 2022
  • [6] Identification of selected hydrophobic organic contaminants in wastewater with semipermeable membrane devices (SPMDS)
    Stuer-Lauridsen, F
    Kjolholt, J
    WATER RESEARCH, 2000, 34 (13) : 3478 - 3482
  • [7] Field Calibration of Semipermeable Membrane Devices (SPMDs) for Persistent Organic Pollutant Monitoring in a Reservoir
    Narvaez Valderrama, Jhon Fredy
    Gonzalez, Juan D.
    Porras, Jazmin
    Molina, Francisco J.
    WATER, 2023, 15 (07)
  • [8] Using semipermeable membrane devices (SPMDs) to assess the toxicity and teratogenicity of aquatic amphibian habitats
    Bridges, CM
    Little, EE
    MULTIPLE STRESSOR EFFECTS IN RELATION TO DECLINING AMPHIBIAN POPULATIONS, 2003, 1443 : 159 - 168
  • [9] Uptake of chlorohydrocarbons from soil by lipid-containing semipermeable membrane devices (SPMDs)
    Rantalainen, AL
    Paasivirta, J
    Herve, S
    CHEMOSPHERE, 1998, 36 (06) : 1415 - 1427
  • [10] Field use of semipermeable membrane devices (SPMDs) for passive air sampling of polycyclic aromatic hydrocarbons: Opportunities and limitations
    Piccardo, M. T.
    Stella, A.
    Pala, M.
    Balducci, D.
    Valerio, F.
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (16) : 1947 - 1951