Simultaneous Determination of Atractylenolide I and II in Rat Plasma by UPLC-MS/MS and Its Application to Pharmacokinetic Study after Intravenous Administration

被引:10
|
作者
Chen, Lianguo [1 ]
Wu, Haiya [2 ,3 ]
Tu, Xiaoting [4 ]
Zhao, Yi [4 ]
Jiang, Yanyan [4 ]
Wen, Congcong [4 ]
Luo, Yue [2 ,3 ]
机构
[1] Wenzhou Peoples Hosp, Dept Pharm, Wenzhou, Peoples R China
[2] Wenzhou Med Univ, Affiliated Hosp 2, Wenzhou, Peoples R China
[3] Wenzhou Med Univ, Yuying Childrens Hosp, Wenzhou, Peoples R China
[4] Wenzhou Med Univ, Lab Anim Ctr, Wenzhou, Peoples R China
关键词
Atractylenolide I; atractylenolide II; UPLC-MS/MS; pharmacokinetics; plasma; ATRACTYLODES MACROCEPHALA; TISSUE DISTRIBUTION; MASS-SPECTROMETRY; MOUSE; MODEL;
D O I
10.1556/1326.2017.00274
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atractylodis exerted a variety of pharmacological effects such as anti-tumor, anti-inflammatory, anti-bacterial, and anti-aging effects etc. The major ingredients of Atractylodis are atractylenolide I and II that exhibited activities in anti-inflammatory and anticancer. In this work, a sensitive and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determination of atractylenolide I and II in rat plasma was developed. The UPLC-MS/MS method was validated for selectivity, linearity, accuracy, precision, recovery, and stability with a total run time of 4.0 min. After addition of atractylenolide III as an internal standard (IS), protein precipitation by acetonitrile was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 mm x 50 mm, 1.7 mu m) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reactions monitoring (MRM) mode was used for quantification using target fragment ions m/z 231.1 -> 185.1 for atractylenolide I, m/z 233.1 -> 91.0 for II, and m/z 249 -> 0.231.1 for IS. Calibration plots were linear throughout the range 1-1000 ng/mL for atractylenolide I and II in rat plasma. Mean recoveries of atractylenolide I and II in rat plasma ranged from 86.2% to 96.3%. Relative standard deviation (RSD) of intra-day and inter-day precision was both less than 12%. The accuracy of the method was between 91.0% and 109.0%. The method was successfully applied to pharmacokinetic study of atractylenolide I and II after intravenous administration in rats.
引用
收藏
页码:8 / 11
页数:4
相关论文
共 50 条
  • [1] Determination of Oxypaeoniflorin in Rat Plasma after Intravenous Administration by UPLC-MS/MS and its Application to a Pharmacokinetic Study
    Lei, Houxing
    Chen, Minle
    Song, Huanchun
    Tong, Shuhua
    You, Pei
    Wang, Xiaoyu
    Wang, Shuanghu
    LATIN AMERICAN JOURNAL OF PHARMACY, 2017, 36 (03): : 515 - 520
  • [2] Simultaneous determination and pharmacokinetic study of Atractylenolide I, II and III in rat plasma after intragastric administration of Baizhufuling extract and Atractylodis extract by UPLC-MS/MS
    Yan, Han
    Sun, Yuanyuan
    Zhang, Qili
    Yang, Mingjing
    Wang, Xiaorui
    Wang, Yang
    Yu, Zhiguo
    Zhao, Yunli
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 993 : 86 - 92
  • [3] Determination and Pharmacokinetic Study of Avicularin in Rat Plasma by UPLC-MS/MS after Intravenous Administration
    Li, Yuan
    Lin, Zixia
    Peng, Xiufa
    Chen, Wenhao
    Wen, Congcong
    Song, Huanchun
    Tong, Shuhua
    Wang, Shuanghu
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (10): : 2309 - 2313
  • [4] Determination and Pharmacokinetic Study of Cyasterone In Rat Plasma after Intravenous Administration by UPLC-MS/MS
    Song, Huanchun
    Lin, Zixia
    Tong, Shuhua
    Zhang, Jing
    Dong, Yanwen
    Chen, Junyan
    Mo, Jingjing
    Wen, Congcong
    Zhou, Yunfang
    Wang, Shuanghu
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (10): : 2196 - 2201
  • [5] Pharmacokinetic Study of Segetalin A in Rat Plasma After Intravenous Administration by UPLC-MS/MS
    Jiang, Yi
    Chen, Junyan
    Chen, Bingbao
    Dong, Yanwen
    Chen, Cheng
    Mo, Jingjing
    Xu, Haibo
    Zhang, Qinglian
    Wang, Shuanghu
    Zhou, Yunfang
    Wen, Congcong
    Fang, Bingmu
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (09): : 2050 - 2055
  • [6] Determination and Pharmacokinetic Study of Synephrine in Rat by UPLC-MS/MS After Intravenous Administration
    Xie, Haili
    Wang, Zhe
    Wang, Qianqian
    Zhang, Jing
    Chen, Junyan
    Dong, Yanwen
    Zhou, Hua
    Chen, Dongxin
    Wang, Shuanghu
    Zhou, Yunfang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2017, 36 (06): : 1193 - 1197
  • [7] Pharmacokinetic study of ardisiacrispin A in rat plasma after intravenous administration by UPLC-MS/MS
    Fang, Bingmu
    Bao, Shihui
    Wang, Shuanghu
    Chen, Minle
    Chen, Bingbao
    Su, Ke
    Wen, Congcong
    Zhou, Yunfang
    Wang, Xianqin
    Jin, Yuepeng
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (03)
  • [8] Simultaneous determination of entecavir and lamivudine in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study
    Jiang, Qikun
    Liu, Yan
    Wang, Yunjie
    Sun, Yinghua
    Li, Bo
    Li, Zhenbao
    Lu, Tianshu
    Wang, Shang
    He, Zhonggui
    RSC ADVANCES, 2016, 6 (75): : 70990 - 70998
  • [9] Simultaneous determination of mangiferin and neomangiferin in rat plasma by UPLC-MS/MS and its application for pharmacokinetic study
    Qiu, Xiangjun
    Zhao, Jian-long
    Hao, Cong
    Yuan, Canli
    Tian, Nuan
    Xu, Zhi-sheng
    Zou, Ruan-min
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 124 : 138 - 142
  • [10] Simultaneous determination of parecoxib sodium and its active metabolite valdecoxib in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study after intravenous and intramuscular administration
    Liu, Meina
    Yu, Qiuyang
    Li, Ping
    Zhu, Meng
    Fang, Mingming
    Sun, Bingjun
    Sun, Mengchi
    Sun, Yinghua
    Zhang, Peng
    He, Zhonggui
    Sun, Jin
    Wang, Yongjun
    Liu, Xiaohong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 220 - 229