Optimization of Bandwidth and Signal Responses of Optically Pumped Atomic Magnetometers for Biomagnetic Applications

被引:20
|
作者
Kamada, Keigo [1 ]
Taue, Shuji [1 ]
Kobayashi, Tetsuo [1 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto 6158510, Japan
关键词
LINES;
D O I
10.1143/JJAP.50.056602
中图分类号
O59 [应用物理学];
学科分类号
摘要
Recently developed ultrasensitive optically pumped atomic magnetometers are promising for biomagnetic measurements such as magnetoencephalograms and magnetocardiograms. The magnetometer's bandwidth and amplitude of signal response are important factors for biomagnetic measurements. These factors depend on various operating parameters such as power density and wavelengths of laser beams. By focusing on the transverse spin relaxation time, we theoretically and experimentally studied the change in the bandwidth and amplitude of the signal response. By considering the effect of the attenuation of a pump beam inside a cell, we showed good agreement between theoretical and experimental results. Furthermore, the magnetometer's integrated performances for the factors were evaluated by changing the power density of the pump beam. Measured data indicated that the bandwidth of signal response depended on the power density of the pump beam and that the bandwidth could be tuned to a desirable frequency range. (C) 2011 The Japan Society of Applied Physics
引用
收藏
页数:7
相关论文
共 43 条
  • [1] Optimization of Bandwidth and Signal Responses of Optically Pumped Atomic Magnetometers for Biomagnetic Applications (vol 50, 056602, 2011)
    Kamada, Keigo
    Taue, Shuji
    Kobayashi, Tetsuo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (01)
  • [2] Microfabricated Optically-Pumped Magnetometers for Biomagnetic Applications
    Knappe, Svenja
    Alem, Orang
    Sheng, Dong
    Kitching, John
    8TH SYMPOSIUM ON FREQUENCY STANDARDS AND METROLOGY 2015, 2016, 723
  • [3] Optically pumped magnetometers enable a new level of biomagnetic measurements
    Sander, Tilmann
    Jodko-Wladzinska, Anna
    Hartwig, Stefan
    Bruehl, Ruediger
    Middelmann, Thomas
    ADVANCED OPTICAL TECHNOLOGIES, 2020, 9 (05) : 247 - 251
  • [4] Magnetic Field Mapping and Biaxial Vector Operation for Biomagnetic Applications Using High-Sensitivity Optically Pumped Atomic Magnetometers
    Taue, Shuji
    Sugihara, Yasuyuki
    Kobayashi, Tetsuo
    Ishikawa, Kiyoshi
    Kamada, Keigo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (11)
  • [5] Magnetic field mapping and biaxial vector operation for biomagnetic applications using high-sensitivity optically pumped atomic magnetometers
    Graduate School of Engineering, Kyoto University, Kyoto 615-8510, Japan
    不详
    Jpn. J. Appl. Phys., 11 PART 1
  • [6] Improved Biomagnetic Signal-To-Noise Ratio and Source Localization Using Optically Pumped Magnetometers with Synthetic Gradiometers
    Xiang, Jing
    Yu, Xiaoqian
    Bonnette, Scott
    Anand, Manish
    Riehm, Christopher D.
    Schlink, Bryan
    Diekfuss, Jed A.
    Myer, Gregory D.
    Jiang, Yang
    BRAIN SCIENCES, 2023, 13 (04)
  • [7] OPTICALLY PUMPED ATOMIC MAGNETOMETERS AFTER 3 DECADES
    ALEXANDROV, EB
    BONCHBRUEVICH, VA
    OPTICAL ENGINEERING, 1992, 31 (04) : 711 - 717
  • [8] Compensation System for Biomagnetic Measurements with Optically Pumped Magnetometers inside a Magnetically Shielded Room
    Jodko-Wladzinska, Anna
    Wildner, Krzysztof
    Palko, Tadeusz
    Wladzinski, Michal
    SENSORS, 2020, 20 (16) : 1 - 14
  • [9] Progress in Biomagnetic Signal Measurements with Ultra-Sensitive Atomic Magnetometers
    Wang Xiaofei
    Sun Xianping
    Zhao Xiuchao
    Zhu Maohua
    Ye Chaohui
    Zhou Xin
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (02):
  • [10] Differential Measurement With the Balanced Response of Optically Pumped Atomic Magnetometers
    Ichihara, Sunao
    Mizutani, Natsuhiko
    Ito, Yosuke
    Kobayashi, Tetsuo
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (08)