Peculiarities of the switching performance of two 24 kV - Vacuum interrupters in series

被引:0
|
作者
Fugel, T [1 ]
Koenig, D [1 ]
机构
[1] Darmstadt Univ Technol, High Voltage Lab, D-64283 Darmstadt, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The breaking capability of two vacuum interrupters in series and their behaviour with added grading capacitors has already been reported in preliminary publications. In the first part of this paper the breaking capability of the series arrangement in dependency of arcing time, recovery voltage and test current is compared with the performance of a single tube. Within these investigations the influence of the test current on the breaking capability of the double arrangement is shown. The second part of the work deals with the performance of the series arrangement during the re-ignition of one of the tubes. Tests with simultaneous openings of the contacts are presented which demonstrate that even one of the two tubes is able to withstand the total TRV in case of re-ignition of the other tube. Immediately after are-extinguishing the previous re-ignited tube is able to recover and to take its part of the total TRV again. As a result the double arrangement is able to interrupt the test current.
引用
收藏
页码:411 / 414
页数:4
相关论文
共 50 条
  • [1] Switching performance of two 24 kV vacuum interrupters in series
    Fugel, T
    Koenig, D
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (02) : 164 - 168
  • [2] Withstand voltage characteristics of two series vacuum interrupters
    Shiba, Yuji
    Ide, Naotaka
    Ichikawa, Hiroki
    Matsui, Yoshihiko
    Sakaki, Masayuki
    Yanabu, Satoru
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (04) : 879 - 884
  • [3] Dielectric Strength of Two Series Connected Vacuum Interrupters
    Alferov, D. F.
    Belkin, G. S.
    Pertsev, A. A.
    Romochkin, Yu. G.
    Rylskaya, L. A.
    Sidorov, V. A.
    ISDEIV 2008: PROCEEDINGS OF THE XXIIIRD INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, 2008, : 121 - 124
  • [4] Breaking performance of a capacitive-graded series design of two 24 kV vacuum circuit breakers
    Fugel, T
    Koenig, D
    ISDEIV: XXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, 2002, 20 : 360 - 363
  • [5] Capacitive Current Switching Capability of 72.5 kV High-Voltage Vacuum Interrupters
    Giere, S.
    Renz, R.
    Richter, F.
    Trapp, N.
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 217 - 220
  • [6] Switching of Capacitive Current with Vacuum Interrupters
    Sandolache, G.
    Ernst, U.
    Godechot, X.
    Kantas, S.
    Hairour, M.
    Dalmazio, L.
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 128 - 131
  • [8] Capacitive Current Switching Performance of Vacuum Interrupters with Different Magnetic Fields
    Zhao, Feng
    Hu, Biao
    Yang, He
    Liu, Zhiyuan
    2016 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 2, 2016,
  • [9] Concept of Series Connected Vacuum Interrupters
    Kulkarni, Sandeep
    Hemachander, M.
    Kumar, Arun S.
    Andrews, Lalichan
    Acharya, Viren
    Maheswaran, C.
    Rayudu, Srinivas
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 517 - 520
  • [10] Influence of grading capacitors on the breaking capacity of two vacuum interrupters in series
    Betz, T
    König, D
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (04) : 405 - 409