A MATHEMATICAL MODEL OF SEMICONDUCTOR DETECTOR GAMMA-EFFICIENCY CALIBRATION FOR RECTANGULAR CUBOID (BRICK-SHAPE) SOURCES

被引:4
|
作者
Mihaljevic, Nikola N. [1 ,2 ]
Jovanovic, Slobodan L. [2 ,3 ]
Dlabac, Aleksandar D. [2 ]
Badawi, Mohamed S. [4 ,5 ]
机构
[1] Univ Montenegro, Maritime Fac, Dept Math, Kotor, Montenegro
[2] Univ Montenegro, Ctr Nucl Competence & Knowledge Management, Podgorica, Montenegro
[3] Univ Montenegro, Fac Math & Nat Sci, Dept Phys, Podgorica, Montenegro
[4] Beirut Arab Univ, Fac Sci, Dept Phys, Beirut, Lebanon
[5] Alexandria Univ, Fac Sci, Phys Dept, Alexandria, Egypt
来源
关键词
gamma spectrometry; detection efficiency; detector calibration; rectangular cuboid source; mathematical model; numerical testing; applicability; ENERGY PEAK EFFICIENCY;
D O I
10.2298/NTRP1802139M
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Rectangular cuboid (rectangular parallelepiped), i.e., brick-shape sources are not really common in general gamma-spectrometry practice with semiconductor detectors, where axially symmetrical sources prevail. However, IN some particular applications, like radioactivity control of food or construction materials (for monitoring and regulatory purposes, radiological emergency preparedness, or in the aftermath of nuclear accidents), brick shapes may come to significance. In order to simplify routine/repetitive low activity measurements, it is easier and more practical to measure the radioactivity of these sources as such, i.e., without transforming them into "regular" (cylindrical or Marinelli) shapes. This saves considerably on laboratory time, workforce and consumables - thus eventually cutting the cost of analysis and improving laboratory performance. In addition, the accuracy of the analytical results is enhanced, as the possibilities for systematic errors are reduced. To that aim, in the present work a mathematical model for brick-source efficiency calibration is developed. The well known, accurate and widely used efficiency transfer principleis applied, together with detector efficiency calculations based on the effective solid angle (Omega) over bar concept. For testing purposes, comparisons are made with previously developed and well established mathematical models for detector calibration involving axially symmetrical sources (point, disc, and cylinder). Namely, brick sources were regarded as a sort of interpolation between the outer and inner cylinder of the same height, for which efficiencies could be accurately determined by numerical calculations (software ANGLE). For the sake of completeness, the equiroluminous cylinders were taken into account as well. Brick shape sources of various sizes and proportions were examined; when approaching zero dimensions, results were obtained for point and disc sources. All calculations were performed in gamma energy range 50-3000 keV. The results are consistent and logical, with no discrepancies indicating bugs or systematic errors - thus convincingly confirming the fundamentality and reliability of the model. The model is about to be incorporated into ANGLE software as a new functionality, so as to make it available to gamma spectrometry community.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 7 条
  • [1] ANGLE v2.1-New version of the computer code for semiconductor detector gamma-efficiency calculations
    Jovanovic, S.
    Dlabac, A.
    Mihaljevic, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (02): : 385 - 391
  • [2] Detector Efficiency Calibration for Extended Gamma-Ray Sources
    dos Santos, Roberto M.
    Genezini, Frederico A.
    Zahn, Guilherme S.
    XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [3] ANGLE SOFTWARE FOR SEMICONDUCTOR DETECTOR GAMMA-EFFICIENCY CALCULATIONS AND POSSIBILITIES FOR ITS APPLICATIONS TO CULTURAL HERITAGE OBJECTS CHARACTERIZATION
    Jovanovic, Slobodan
    Dlabac, Aleksandar
    SCIENCE FOR CULTURAL HERITAGE: TECHNOLOGICAL INNOVATION AND CASE STUDIES IN MARINE AND LAND ARCHAEOLOGY IN THE ADRIATIC REGION AND INLAND, 2010, : 247 - 257
  • [4] ONLINE GAMMA-EFFICIENCY CALIBRATION USING FISSION-PRODUCED XE-138 AND CS-138 SOURCES
    ACHTERBERG, E
    IGLESIAS, FC
    JECH, AE
    MORAGUES, JA
    OTERO, D
    PEREZ, ML
    PROTO, AN
    ROSSI, JJ
    SCHEUER, W
    NUCLEAR INSTRUMENTS & METHODS, 1974, 116 (03): : 453 - 455
  • [5] A GENERALIZED MATHEMATICAL MODEL FOR EFFICIENCY CALIBRATION OF GAMMA DETECTORS Application to Practical Cases
    Mihaljevic, Nikola N.
    Jovanovic, Slobodan I.
    Dlabac, Aleksandar D.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (01): : 34 - 46
  • [6] A NEW MATHEMATICAL MODEL FOR DETERMINING FULL-ENERGY PEAK EFFICIENCY OF AN ARRAY OF TWO GAMMA DETECTORS COUNTING RECTANGULAR PARALLELEPIPED SOURCES
    Badawi, Mohamed S.
    Krar, Mohamed E.
    El-Khatib, Ahmed M.
    Jovanovic, Slobodan I.
    Dlabac, Aleksandar D.
    Mihaljevic, Nikola N.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04): : 370 - 380
  • [7] New mathematical approach to calculate the geometrical efficiency using different radioactive sources with gamma-ray cylindrical shape detectors
    Thabet, Abouzeid A.
    Hamzawy, A.
    Badawi, Mohamed S.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (06) : 1271 - 1276