Automated finite element meshing of the lumbar spine: Verification and validation with 18 specimen-specific models

被引:42
|
作者
Campbell, J. Q. [1 ,2 ]
Coombs, D. J. [3 ,4 ]
Rao, M. [5 ]
Rullkoetter, P. J. [3 ]
Petrella, A. J. [1 ]
机构
[1] Colorado Sch Mines, Computat Biomech Grp, 1500 Illinois St, Golden, CO 80401 USA
[2] Vector Sci Inc, Golden, CO USA
[3] Univ Denver, Ctr Orthopaed Biomech, Denver, CO 80208 USA
[4] DePuy Synthes Trauma, W Chester, PA USA
[5] BD Med Medicat & Procedural Solut, Franklin Lakes, NJ USA
基金
美国国家科学基金会;
关键词
Lumbar spine; Finite element analysis; Automation; Subject-specific; Validation; SENSITIVITY; LOADS; ROTATION;
D O I
10.1016/j.jbiomech.2016.05.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to seek broad verification and validation of human lumbar spine finite element models created using a previously published automated algorithm. The automated algorithm takes segmented CT scans of lumbar vertebrae, automatically identifies important landmarks and contact surfaces, and creates a finite element model. Mesh convergence was evaluated by examining changes in key output variables in response to mesh density. Semi-direct validation was performed by comparing experimental results for a single specimen to the automated finite element model results for that specimen with calibrated material properties from a prior study. Indirect validation was based on a comparison of results from automated finite element models of 18 individual specimens, all using one set of generalized material properties, to a range of data from the literature. A total of 216 simulations were run and compared to 186 experimental data ranges in all six primary bending modes up to 7.8 Nm with follower loads up to 1000 N. Mesh convergence results showed less than a 5% difference in key variables when the original mesh density was doubled. The semi-direct validation results showed that the automated method produced results comparable to manual finite element modeling methods. The indirect validation results showed a wide range of outcomes due to variations in the geometry alone. The studies showed that the automated models can be used to reliably evaluate lumbar spine biomechanics, specifically within our intended context of use: in pure bending modes, under relatively low non-injurious simulated in vivo loads, to predict torque rotation response, disc pressures, and facet forces. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2669 / 2676
页数:8
相关论文
共 50 条
  • [1] Strain in the ostrich mandible during simulated pecking and validation of specimen-specific finite element models
    Rayfield, Emily J.
    JOURNAL OF ANATOMY, 2011, 218 (01) : 47 - 58
  • [2] Development of specimen-specific finite element models of human vertebrae for the analysis of vertebroplasty
    Wijayathunga, V. N.
    Jones, A. C.
    Oakland, R. J.
    Furtado, N. R.
    Hall, R. M.
    Wilcox, R. K.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H2) : 221 - 228
  • [3] Material characterization of liver parenchyma using specimen-specific finite element models
    Untaroiu, Costin D.
    Lu, Yuan-Chiao
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 26 : 11 - 22
  • [4] Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data
    Kallemeyn, Nicole
    Gandhi, Anup
    Kode, Swathi
    Shivanna, Kiran
    Smucker, Joseph
    Grosland, Nicole
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (05) : 482 - 489
  • [5] Specimen-specific finite element models of human head obtained with mesh-morphing
    Szmurlo, Robert
    Starzynski, Jacek
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (04): : 47 - 49
  • [6] Specimen-specific finite element representations of implanted hip capsules
    Krishnan, Ahilan Anantha
    Myers, Casey A.
    Scinto, Michael
    Marshall, Brittany N.
    Clary, Chadd W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (06) : 751 - 764
  • [7] Inter-Specimen Analysis of Diverse Finite Element Models of the Lumbar Spine
    Doulgeris, James
    Lin, Maohua
    Lee, William
    Aghayev, Kamran
    Papanastassiou, Ioannis Dimitri
    Tsai, Chi-Tay
    Vrionis, Frank D.
    BIOENGINEERING-BASEL, 2024, 11 (01):
  • [8] INFLUENCE OF SPECIMEN-SPECIFIC TRABECULAR ANISOTROPY ON QCT-BASED FINITE ELEMENT ANALYSES OF LUMBAR VERTEBRA
    Unnikrishnan, Ginu U.
    Barest, Glenn D.
    Berry, David B.
    Hussein, Amira I.
    Morgan, Elise F.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 537 - 538
  • [9] Specimen-Specific Finite Element Models for Predicting Fretting Wear in Total Hip Arthroplasty Tapers
    Baumann, Andrew P.
    Vesnovsky, Oleg
    Topoleski, L. D. Timmie
    Donaldson, Finn E.
    McMinn, Nicole L. L.
    Vignola, Amelia
    Di Prima, Matthew
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (07):
  • [10] Mesh-morphing algorithms for specimen-specific finite element modeling
    Sigal, Ian A.
    Hardisty, Michael R.
    Whyne, Cari M.
    JOURNAL OF BIOMECHANICS, 2008, 41 (07) : 1381 - 1389