BACKGROUND AND PURPOSE: Studies to determine the value of noninvasive neurovascular studies for the effectiveness of treatment and long-term follow-up of dural arteriovenous fistulas (AVFs) are of clinical importance. We determined whether the serial changes of carotid duplex sonography (CDS) were correlated with the evolution of dural AVF status after treatment or follow-up. METHODS: Four parameters of CDS were studied in two groups of patients with dural AVF: resistance index, end diastolic velocity, peak systolic velocity, and flow volume of the external carotid artery (ECA). The first group included 13 patients who received endovascular therapy, the efficacy of which was determined by the results of postembolization angiography. In the second group, 16 patients received only clinical and CDS follow-up. Evolution of clinical symptoms was recorded and classified as deteriorating, stationary, or improving. Patients underwent CDS before and after treatment (group 1) or at long-term follow-up (group 2). RESULTS: In the,first group, the resistance index of the ECA increased in patients with occluded or nearly occluded dural AVF after embolization (n = 7, P = .01), but it did not change significantly in patients with partial treatment (n = 6, P = .11). Of patients with occluded or nearly occluded dural AVF after embolization, the ECA resistance index increased in patients with noncavernous sinus dural AVF (n = 5, P = .003) but not in patients with cavernous sinus dural AVF (n = 2, P = .48). In the second group, CDS parameters-particularly the resistance. index-were well correlated with clinical status during follow-up. CONCLUSION: The resistance index of the ECA is correlated with the effectiveness of treatment and clinical evolution of dural AVF.
引用
收藏
页码:625 / 629
页数:5
相关论文
共 50 条
  • [1] Screen for intracranial dural arteriovenous fistulae with carotid duplex sonography
    Tsai, L-K
    Yeh, S-J
    Chen, Y-C
    Liu, H-M
    Jeng, J-S
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2009, 80 (11): : 1225 - 1229
  • [2] Diagnosis of intracranial dural arteriovenous fistulas by carotid duplex sonography
    Tsai, LK
    Jeng, JS
    Wang, HJ
    Yip, PK
    Liu, HM
    JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (06) : 785 - 791
  • [3] Embolization of spinal dural arteriovenous fistulae: Results and follow-up
    Niimi, Y
    Berenstein, A
    Setton, A
    Neophytides, A
    NEUROSURGERY, 1997, 40 (04) : 675 - 682
  • [4] Embolization of spinal dural arteriovenous fistulae: Results and follow-up - Comment
    Barnwell, SL
    NEUROSURGERY, 1997, 40 (04) : 683 - 683
  • [5] Intracranial Dural Arteriovenous Fistulae
    Reynolds, Matthew R.
    Lanzino, Giuseppe
    Zipfel, Gregory J.
    STROKE, 2017, 48 (05) : 1424 - +
  • [6] Assessment of dural arteriovenous fistulae by transcranial color-coded duplex sonography
    Harrer, JU
    Popescu, O
    Henkes, HH
    Klötzsch, C
    STROKE, 2005, 36 (05) : 976 - 979
  • [7] VALIDITY OF CAROTID DUPLEX SONOGRAPHY IN SCREENING FOR INTRACRANIAL DURAL ARTERIOVENOUS FISTULA AMONG PATIENTS WITH PULSATILE TINNITUS
    Tsai, Li-Kai
    Yeh, Shin-Joe
    Tang, Sung-Chun
    Hsieh, Yu-Lin
    Chen, Ying-An
    Liu, Hon-Man
    Jeng, Jiann-Shing
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02): : 407 - 412
  • [8] Duplex ultrasound of external carotid artery branches for the detection of dural arteriovenous fistulae
    Arning, C
    Grzyska, U
    Lachenmayer, L
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (02): : 236 - 241
  • [9] POSTOPERATIVE FOLLOW-UP AFTER CAROTID THROMBENDARTERECTOMY USING DUPLEX SONOGRAPHY
    ECKMANN, A
    KUHN, FP
    GRONNIGER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1986, 145 (06): : 639 - 641
  • [10] Follow-up of polytetrafluoroethylene arteriovenous fistulae for haemodialysis
    Modarai, B
    Dasgupta, P
    Taylor, J
    Koffman, G
    Khan, MS
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2005, 59 (09) : 1005 - 1007