Effective length factor of columns in flexibly jointed and braced frames

被引:20
|
作者
Kishi, N [1 ]
Chen, WF
Goto, Y
Komuro, M
机构
[1] Muroran Inst Technol, Muroran, Hokkaido 050, Japan
[2] Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
[3] Nagoya Inst Technol, Nagoya, Aichi 466, Japan
关键词
effective length factor; column buckling; semi-rigid connection; bifurcation; braced frame;
D O I
10.1016/S0143-974X(98)80104-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to rationally evaluate the stability of columns in flexibly jointed and braced frames, the governing equations for determining the effective length factor (K-factor) of columns are derived considering the effects of the non-linear moment-rotation characteristics of beam-to-column connections. In this study, to derive the equations, the alignment chart approach is used and a recent study on the stability of flexibly jointed frames and the concept of the Shanley's inelastic column buckling theory are applied. With a proper evaluation of the tangent connection stiffness for semi-rigid beam-to-column connections at buckling state and with the introduction of the modified relative stiffness factors, the alignment chart in the present AISC-LRFD specification can be used to find the corresponding column K-factor in flexibly jointed frames. This is described in this paper. Furthermore, using two flexibly jointed and braced portal and one-bay two-story frame examples, the effects of the non-linear moment-rotation characteristics of connections on the K-factor are numerically studied and the K-factors obtained by two simplified methods are compared with the present method. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:93 / 118
页数:26
相关论文
共 50 条
  • [1] Effective length factor for columns in braced frames
    Duan, Lian
    Chen, Wai-Fah
    Journal of structural engineering New York, N.Y., 1988, 114 (10): : 2357 - 2370
  • [2] EFFECTIVE LENGTH FACTOR FOR COLUMNS IN BRACED FRAMES
    DUAN, L
    CHEN, WF
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1988, 114 (10): : 2357 - 2370
  • [3] Effective Length of Reinforced Concrete Columns in Braced Frames
    Timo K. Tikka
    S. Ali Mirza
    International Journal of Concrete Structures and Materials, 2014, 8 : 99 - 116
  • [4] Effective Length of Reinforced Concrete Columns in Braced Frames
    Tikka, Timo K.
    Mirza, S. Ali
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2014, 8 (02) : 99 - 116
  • [5] Effective length factor for columns in braced frames considering axial forces on restraining members
    Mahini, MR
    Seyyedian, H
    STRUCTURAL ENGINEERING AND MECHANICS, 2006, 22 (06) : 685 - 700
  • [6] A new method for determining the effective length factor of columns in partially braced frames on elastic supports
    Slimani, Adel
    Belaid, Toufik
    Saidani, Messaou
    Ammari, Fatiha
    Adman, Redouane
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 85 (06) : 825 - 835
  • [7] EFFECTIVE LENGTH FACTOR FOR COLUMNS IN UNBRACED FRAMES
    DUAN, L
    CHEN, WF
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1989, 115 (01): : 149 - 165
  • [8] Effective length factor of columns in semirigid and unbraced frames
    Kishi, N
    Chen, WF
    Goto, Y
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (03): : 313 - 320
  • [9] Effective length factor of columns in semirigid and unbraced frames
    Kishi, N.
    Chen, W.F.
    Goto, Y.
    Journal of structural engineering New York, N.Y., 1997, 123 (03): : 313 - 320
  • [10] EVALUATION OF EFFECTIVE LENGTH FACTORS IN BRACED FRAMES
    FRASER, DJ
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1983, 10 (01) : 18 - 26