Microbial diversity of biofilms in dental unit water systems

被引:75
|
作者
Singh, R
Stine, OC
Smith, DL
Spitznagel, JK
Labib, ME
Williams, HN
机构
[1] Univ Maryland, Sch Dent, Dept Oral & Craniofacial Biol Sci, Baltimore, MD 21201 USA
[2] Univ Maryland, Dept Epidemiol & Prevent Med, Baltimore, MD 21201 USA
[3] Univ Maryland, Dept Periodont, Baltimore, MD 21201 USA
[4] Novaflux Technol, Princeton, NJ 08540 USA
关键词
D O I
10.1128/AEM.69.6.3412-3420.2003
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We investigated the microbial diversity of biofilms found in dental unit water systems (DUWS) by three methods. The first was microscopic examination by scanning electron microscopy (SEM), acridine orange staining, and fluorescent in situ hybridization (FISH). Most bacteria present in the biofilm were viable. FISH detected the beta and gamma, but not the alpha, subclasses of Proteobacteria. In the second method, 55 cultivated biofilm isolates were identified with the Biolog system, fatty acid analysis, and 16S ribosomal DNA (rDNA) sequencing. Only 16S identified all 55 isolates, which represented 13 genera. The most common organisms, as shown by analyses of 16S rDNA, belonged to the genera Afipia (28%) and Sphingomonas (16%). The third method was a culture-independent direct amplification and sequencing of 165 subclones from community biofilm 16S rDNA. This method revealed 40 genera: the most common ones included Leptospira (20%), Sphingomonas (14%), Bacillus (7%), Escherichia (6%), Geobacter (5%), and Pseudomonas (5%). Some of these organisms may be opportunistic pathogens. Our results have demonstrated that a biofilm in a health care setting may harbor a vast diversity of organisms. The results also reflect the limitations of culture-based techniques to detect and identify bacteria. Although this is the greatest diversity reported in DUWS biofilms, other genera may have been missed. Using a technique based on jackknife subsampling, we projected that a 25-fold increase in the number of subclones sequenced would approximately double the number of genera observed, reflecting the richness and high diversity of microbial communities in these biofilms.
引用
收藏
页码:3412 / 3420
页数:9
相关论文
共 50 条
  • [1] A review of biofilms and their role in microbial contamination of dental unit water systems (DUWS)
    Walker, JT
    Marsh, PD
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2004, 54 (2-3) : 87 - 98
  • [2] INFLUENCE OF BIOFILMS ON MICROBIAL-CONTAMINATION IN DENTAL UNIT WATER
    WHITEHOUSE, RLS
    PETERS, E
    LIZOTTE, J
    LILGE, C
    JOURNAL OF DENTISTRY, 1991, 19 (05) : 290 - 295
  • [4] The effect of drying dental unit waterline biofilms on the bacterial load of dental unit water
    Fiehn, NE
    Larsen, T
    INTERNATIONAL DENTAL JOURNAL, 2002, 52 (04) : 251 - 254
  • [5] Microbial risk assessment of dental unit water systems in general dental practice in Greece
    Mavridou, A.
    Kamma, J.
    Mandilara, G.
    Delaportas, P.
    Komioti, F.
    WATER SCIENCE AND TECHNOLOGY, 2006, 54 (03) : 269 - 273
  • [6] Effect of water softening and heating on microbial contamination of dental unit systems
    Stampi, S
    Zanetti, F
    deLuca, G
    Romano, G
    Pistacchio, E
    Tonelli, E
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1996, 198 (06): : 522 - 530
  • [7] Microbial diversity in biofilms from corroding heating systems
    Kjellerup, BV
    Thomsen, TR
    Nielsen, JL
    Olesen, BH
    Frolund, B
    Nielsen, PH
    BIOFOULING, 2005, 21 (01) : 19 - 29
  • [8] Microbial biofilm formation and contamination of dental-unit water systems in general dental practice
    Walker, JT
    Bradshaw, DJ
    Bennett, AM
    Fulford, MR
    Martin, MV
    Marsh, PD
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2000, 66 (08) : 3363 - 3367
  • [9] Attitudes of general dental practitioners in Europe to the microbial risk associated with dental unit water systems
    Kamma, J. J.
    Bradshaw, D. J.
    Fulford, M. R.
    Marsh, P. D.
    Frandsen, E.
    Ostergaard, E.
    Schel, A. J.
    ten Cate, J. M.
    Moorer, W. R.
    Mavridou, A.
    Mandilara, G.
    Stoesser, L.
    Kneist, S.
    Araujo, R.
    Contreras, N.
    Goroncy-Bermes, P.
    Burke, F.
    O'Mullane, D.
    O'Sullivan, M.
    Walker, J. T.
    INTERNATIONAL DENTAL JOURNAL, 2006, 56 (04) : 187 - 195
  • [10] Microbial quality of water in dental unit waterlines
    Nikaeen, Mahnaz
    Hatamzadeh, Maryam
    Sabzevari, Zohre
    Zareh, Omolbanin
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2009, 14 (05): : 297 - 300