Design and implementation of a portable physiologic data acquisition system

被引:9
|
作者
Vinecore, Kevin [1 ]
Aboy, Mateo
McNames, James
Phillips, Charles
Agbeko, Rachel
机构
[1] Oregon Hlth & Sci Univ, Portland, OR 97201 USA
[2] Oregon Inst Technol, Portland, OR USA
[3] Portland State Univ, Biomed Signal Proc Lab, Portland, OR 97207 USA
[4] Inst Child Hlth, Portex Unit, Crit Care Grp, London, England
[5] Great Ormond St Hosp Sick Children, Paediat Intens Care Unit, London WC1N 3JH, England
[6] Oregon Hlth & Sci Univ, Div Pediat Crit Care, Dept Pediat, Portland, OR 97201 USA
[7] Harvard Univ, Sch Med, Childrens Hosp, Dept Anesthesia, Boston, MA USA
[8] Harvard Univ, Sch Med, Childrens Hosp, Div Crit Care Med, Boston, MA USA
[9] Novo Nordisk AS, Princeton, NJ USA
关键词
physiologic signals; waveforms; data acquisition; intensive care unit; research;
D O I
10.1097/01.PCC.0000288715.66726.64
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To describe and report the reliability of a portable, laptop-based, real-time, continuous physiologic data acquisition system (PDAS) that allows for synchronous recording of physiologic data, clinical events, and event markers at the bedside for physiologic research studies in the intensive care unit. Design: Descriptive report of new research technology. Setting: Adult and pediatric intensive care units in three tertiary care academic hospitals. Patients: Sixty-four critically ill and injured patients were studied, including 34 adult (22 males and 12 females) and 30 pediatric (19 males and 11 females). Interventions. None. Measurements and Main Results: Data transmission errors during bench and field testing were measured. The PDAS was used in three separate research studies, by multiple users, and for repeated recordings of the same set of signals at various intervals for different lengths of time. Both parametric (1 Hz) and waveform (125-500 Hz) signals were recorded and analyzed. Details of the PDAS components are explained and examples are given from the three experimental physiology-based protocols. Waveform data include electrocardiogram, respiration, systemic arterial pressure (invasive and noninvasive), oxygen saturation, central venous pressure, pulmonary arterial pressure, left and right atrial pressures, intracranial pressure, and regional cerebral blood flow. Bench and field testing of the PDAS demonstrated excellent reliability with 100% accuracy and no data transmission errors. The key feature of simultaneously capturing physiologic signal data and clinical events (e.g., changes in mechanical ventilation, drug administration, clinical condition) is emphasized. Conclusions: The PDAS provides a reliable tool to record physiologic signals and associated clinical events on a second-to-second basis and may serve as an important adjunctive research tool in designing and performing clinical physiologic studies in critical illness and injury.
引用
收藏
页码:563 / 569
页数:7
相关论文
共 50 条
  • [1] Design and Implementation of Portable Multifunctional Data Acquisition Terminal
    Li, He
    Che, Ming
    Li, Jia
    Shi, Yan-tao
    2013 IEEE 15TH INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING AND COMMUNICATIONS & 2013 IEEE INTERNATIONAL CONFERENCE ON EMBEDDED AND UBIQUITOUS COMPUTING (HPCC_EUC), 2013, : 1733 - 1738
  • [2] The Design and Implementation of Portable Agricultural Microclimate Data Acquisition System based on Android Platform
    Gao, Chao
    Yao, Kaixue
    2015 8TH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID), VOL 1, 2015, : 210 - 213
  • [3] Design and implementation of a data acquisition system
    Huo, H
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 781 - 784
  • [4] Design of a Portable System for Sensor Data Acquisition and Transmission
    Yordanov, Rumen
    Miletiev, Rosen
    Kapanakov, Petar
    Iontchev, Emil
    2017 XXVI INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS (ET), 2017,
  • [5] Design and implementation of portable instrument for data acquisition and analysis based on OMAP
    Huang, F
    Su, SJ
    Wang, YK
    Hu, BQ
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 319 - 321
  • [6] Design and implementation of a wireless data acquisition system
    Nagel, JE
    Walker, CF
    IEEE REGION 5 2003 ANNUAL TECHNICAL CONFERENCE, CONFERENCE RECORD, 2003, : 7 - 10
  • [7] Design and Implementation of Data Acquisition System for AETA
    Yang X.
    Yong S.
    Wang X.
    Zhou K.
    Jin X.
    Beijing Daxue Xuebao (Ziran Kexue Ban)/Acta Scientiarum Naturalium Universitatis Pekinensis, 2020, 56 (04): : 600 - 606
  • [8] Design and Implementation of an Ultralow Power Data Acquisition System
    Shi, Chuan
    Zhang, Yang
    Nie, Weirong
    Yan, Liaoliao
    Jiang, Jian
    PROCEEDINGS OF 2013 CHINESE INTELLIGENT AUTOMATION CONFERENCE: INTELLIGENT AUTOMATION & INTELLIGENT TECHNOLOGY AND SYSTEMS, 2013, 255 : 767 - 776
  • [9] Design and Implementation of Active Filter for Data Acquisition System
    Kyu, Mya Thandar
    Aung, Zaw Min
    Naing, Zaw Min
    2009 INTERNATIONAL CONFERENCE ON INFORMATION MANAGEMENT AND ENGINEERING, PROCEEDINGS, 2009, : 406 - +
  • [10] Design and Implementation of Data Acquisition System for EEG Analysis
    Nageshwar, V.
    Sai, Y. Padma
    Rao, K. Subba
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING (IACC), 2016, : 792 - 795