Radiation dose to abdominal organs of the mouse due to 90Y in the urinary bladder

被引:5
|
作者
Lazewatsky, J
Ding, YH
Onthank, D
Silva, P
Solon, E
Robinson, S
机构
[1] Bristol Myers Squibb Med Imaging, N Billerica, MA 01862 USA
[2] Univ Massachusetts, Lowell, MA USA
[3] Quest Pharmaceut Serv, Newark, DE USA
关键词
Y Yttrium-90; targeted mouse toxicology; preclinical bladder radiation; dosimetry; Monte Carlo; beta cancer animal model;
D O I
10.1089/108497803322285152
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiation dosimetry estimates in mice have proven useful in evaluating therapeutic radiopharmaceuticals. Current models for mice do not take into account the dose to abdominal organs from radioactivity in the urinary bladder. Although the dose from this source is probably low for slowly clearing compounds such as antibodies, it may be considerable for small molecule Y-90 conjugates undergoing rapid renal clearance. To evaluate this possibility, we modeled the mouse bladder as a 6 mm sphere, surrounded by a 0.5 mm thick shell. We then calculated the radiation dose that might be received by the shell and by more distant points, using the point kernel method with the Loevinger analytical point kernel. A Monte Carlo calculation using EGS4 was also performed. Surface dose calculations were compared with in vitro experimental data. LiF TLD dosimeters were placed directly under five separated, flat-bottomed, 6-mm-diameter wells containing Y-90 on a 96-well plate. Dose versus distance from the mouse urinary bladder was calculated using kinetic data from imaging studies of a renally cleared In-111 analog compound currently under investigation. From this, it was estimated that whole body administration of 34.8 MBq of the Y-90 analog compound would yield a bladder wall dose estimate of approximately 98 Gy. Structures within 2 mm. of the bladder would receive additional estimated doses of at least 15 Gy. This radiation dose approaches that which is known from external beam data to cause fibrosis in mice. Because of the greater size of the human bladder compared with that of the mouse relative to the range of Y-90 beta particles, the radiation exposure from the same residence time in man was estimated to be considerably lower. This highlights a potential practical limitation of extrapolating radiotoxicity findings in the mouse to human subjects.
引用
收藏
页码:413 / 419
页数:7
相关论文
共 50 条
  • [1] Radiation protection in metabolic radiotherapy with 90Y
    Tosi, G.
    Marzo, K.
    Provenzano, F.
    Chiti, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S392 - S392
  • [2] Patient dosimetry for 90Y selective internal radiation treatment based on 90Y PET imaging
    Ng, Sherry C.
    Lee, Victor H.
    Law, Martin W.
    Liu, Rico K.
    Ma, Vivian W.
    Tso, Wai Kuen
    Leung, To Wai
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 212 - 221
  • [3] Stereotactic body radiation therapy (SBRT) following Yttrium-90 (90Y) selective internal radiation therapy (SIRT): a feasibility planning study using 90Y delivered dose
    Mee, Stephen F.
    Polan, Daniel F.
    Dewaraja, Yuni K.
    Cuneo, Kyle C.
    Gemmete, Joseph J.
    Evans, Joseph R.
    Lawrence, Theodore S.
    Dow, Janell S.
    Mikell, Justin K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (06):
  • [4] Lung Dose Measured on Postradioembolization 90Y PET/CT and Incidence of Radiation Pneumonitis
    Stella, Martina
    van Rooij, Rob
    Lam, Marnix G. E. H.
    de Jong, Hugo W. A. M.
    Braat, Arthur J. A. T.
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (07) : 1075 - 1080
  • [5] Monte Carlo simulation of radiation dose emission by patients administered with 90Y labelledradiopharmaceuticals
    Lo Meo, S.
    Cicoria, G.
    Bergamini, C.
    Pancaldi, D.
    Panebianco, A. S.
    Campanella, F.
    Marengo, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S210 - S210
  • [6] 90Y Scout Dose Imaging In Hepatic Radioembolization
    Kunnen, B.
    van der Velden, S.
    Lam, M. G. E. H.
    Viergever, M. A.
    de Jong, H. W. A. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S195 - S195
  • [7] PET/CT imaging of 90Y radiation synovectomy
    Barber, Thomas W.
    Yap, Kenneth S. K.
    Kalff, Victor
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (05) : 917 - 918
  • [8] Radiation safety considerations with therapeutic 90Y zevalin
    Zhu, XW
    HEALTH PHYSICS, 2003, 85 (02): : S31 - S35
  • [9] PET/CT imaging of 90Y radiation synovectomy
    Thomas W. Barber
    Kenneth S. K. Yap
    Victor Kalff
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 917 - 918
  • [10] What is the sensitivity of 90Y SPECT to microscale dose distribution?
    Oldfield, C.
    Cullen, D.
    Hamilton, D.
    Page, E.
    Robinson, A. P.
    Tipping, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S379 - S379