The Quality Evaluation of Dynamic Spectrum Data

被引:7
|
作者
Li Gang [1 ]
Wang Hui-quan [1 ]
Zhao Zhe [1 ]
Lin Ling [1 ]
Zhou Mei [1 ]
Wu Hong-jie [1 ]
机构
[1] Tianjin Univ, Tianjin Key Lab Biomed Detecting Tech & Instrumen, Tianjin 300072, Peoples R China
关键词
Dynamic spectrum; Quality evaluation; Glucose; Total cholesterol; Hemoglobin;
D O I
10.3964/j.issn.1000-0593(2010)10-2802-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
To eliminate the influence of all factors on non-invasive measurement precision of blood components by dynamic spectrum method during data acquisition process, a quality evaluation criterion of dynamic spectrum data needs to be established to improve the stability of the model and precision of the prediction. The number of stable wavelength as a quality evaluation index for the dynamic spectrum data was presented in this article after further analysis of 110 samples, which were all obtained by in-vivo measurements, and 60 samples were picked up as the satisfactory samples. BP artificial neural network was used to establish the calibration model of subjects' total cholesterol, glucose and hemoglobin values against dynamic spectrum data. The prediction result of the experiment group was improved compared with the control group. The average relative error was decreased from 13.8%, 15.8% and 5.4% to 6.5%, 6.5% and 2.1% respectively, by which the effectiveness of the number of stable wavelength as a quality evaluation index could be proved. By evaluating the quality of the dynamic spectrum data measured, more reliable prediction result can be obtained, which can make the non-invasive measurement of the blood components come to the clinical application sooner.
引用
收藏
页码:2802 / 2806
页数:5
相关论文
共 8 条
  • [1] Development of an implantable skin port sensor for use as an in vivo optical glucose sensing platform
    Gowda, A
    McNichols, RJ
    Fossum, TW
    Rastegar, S
    Coté, GL
    [J]. OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING, 2001, 4263 : 11 - 19
  • [2] Li CW, 2007, PROCEEDINGS OF THE 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOINFORMATICS AND BIOENGINEERING, VOLS I AND II, P1168
  • [3] Li G, 2004, PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, P875
  • [4] Li G., 2004, Life Sci Inst, V5, P33, DOI [10.3969/j.issn.1671-7929.2004.05.009, DOI 10.3969/J.ISSN.1671-7929.2004.05.009]
  • [5] Li G, 2007, CHINESE J ANAL CHEM, V35, P1495
  • [6] Li QX, 2005, P ANN INT IEEE EMBS, P1994
  • [7] LU LN, 2009, J INFRARED MILLIMETE, V30, P1191
  • [8] PETROV YY, 2007, P SPIE INT SOC OPTIC, V6437