Reference signal less Fourier analysis based motion artifact removal algorithm for wearable photoplethysmography devices to estimate heart rate during physical exercises

被引:23
|
作者
Pankaj [1 ]
Kumar, Ashish [2 ]
Komaragiri, Rama [1 ]
Kumar, Manjeet [3 ]
机构
[1] Bennett Univ, Dept Elect & Commun Engn, Greater Noida 201310, Uttar Pradesh, India
[2] Vellore Inst Technol, Sch Elect Engn, Chennai 600127, Tamil Nadu, India
[3] Delhi Technol Univ DTU Rohini, Dept Elect & Commun Engn, Delhi 110042, India
关键词
Photoplethysmographic(PPG) signal; Fast Fourier transform(FFT); Fourier decomposition method (FDM); Motion artifacts(MA); Heart rate (HR) estimation; HR tracking; PPG SIGNALS; REDUCTION; FRAMEWORK;
D O I
10.1016/j.compbiomed.2021.105081
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Context: Accurate and reliable heart rate (HR) estimation using photoplethysmographic (PPG)-enabled wearable devices in real-time during daily life activities is challenging. Problem: A PPG signal recorded using a wearable PPG device is corrupted by motion artifacts. Therefore, the main challenge of monitoring HR in real time is the accurate reconstruction of a clean PPG signal by suppressing motion artifacts. Proposed approach: The proposed algorithm employs the Fourier theory-based Fourier decomposition method (FDM) to suppress motion artifacts and a fast Fourier transform (FFT)-based method to estimate the HR. In this paper, a computationally efficient algorithm that does not require a reference accelerometer signal to suppress motion artifacts to estimate HR in real time during physical activities is proposed. Methodology: The noisy PPG signal is decomposed into a desired set of orthogonal Fourier intrinsic band functions (FIBFs). A clean PPG signal is obtained by discarding the FIBFs corrupted with noise and superpositioning the clean FIBFs. Clean FIBFs were further used to estimate the HR. Results: The proposed method is evaluated by computing the mean absolute error (MAE) and percentage absolute error (PAE) on two publicly available datasets, IEEE SPC (training and test) and BAMI (BAMI-I and BAMI-II). The MAE and PAE values computed with the proposed method using the IEEE SPC dataset were (1.87, 1.71). The MAE and PAE values computed using the proposed method on the BAMI-I and BAMI-II datasets were (1.33, 1.13) and (1.45, 1.17), respectively. The computed MAE and PAE values were more accurate than those of state-of-the-art techniques presented in the literature. Conclusion: Owing to the improved accuracy and speed, the proposed HR estimation algorithm can be implemented in wearable health monitoring devices for continuous and reliable HR estimation in real time. The proposed algorithm can be applied to denoise PPG signals with different sampling rates.
引用
收藏
页数:14
相关论文
共 10 条
  • [1] Heart Rate Monitoring During Intense Physical Activities Using A Motion Artifact Corrupted Signal Reconstruction Algorithm in Wearable Electrocardiogram Sensor
    Salehizadeh, S. M. A.
    Noh, Y.
    Chon, K. H.
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 157 - 162
  • [2] Analysis of photoplethysmogram signal to estimate heart rate during physical activity using fractional fourier transform - A sampling frequency independent and reference signal-less method
    Pankaj
    Kumar, Ashish
    Ashdhir, Aryaman
    Komaragiri, Rama
    Kumar, Manjeet
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 229
  • [3] Motion Artifact Removal in Ambulatory ECG Signal for Heart Rate Variability Analysis
    Berwal, Deepak
    Vandana, C. R.
    Dewan, Sourya
    Jiji, C., V
    Baghini, Maryam Shojaei
    IEEE SENSORS JOURNAL, 2019, 19 (24) : 12432 - 12442
  • [4] Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology
    Carla Alfonso
    Miguel A. Garcia-Gonzalez
    Eva Parrado
    Jessyca Gil-Rojas
    Juan Ramos-Castro
    Lluis Capdevila
    Scientific Reports, 12
  • [5] Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology
    Alfonso, Carla
    Garcia-Gonzalez, Miguel A.
    Parrado, Eva
    Gil-Rojas, Jessyca
    Ramos-Castro, Juan
    Capdevila, Lluis
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] PPG heart rate extraction algorithm based on the motion artifact intensity Classification and removal framework
    Hao, Zihao
    Wang, Jinnan
    Zhang, Ge
    Gao, Lizhen
    Zhang, Xiaoming
    Liu, Jun
    Zhang, Xiaoliang
    Yang, Xiaolei
    Lai, Zhengxi
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 94
  • [7] Enhanced Contactless Heart Rate Monitoring Using Camera with Motion Artifact Removal During Physical Activities
    Vatanparvar, Korosh
    Li, Jiyang
    Gwak, Migyeong
    Zhu, Li
    Kuang, Jilong
    Gao, Alex
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [8] STSR: Spectro-Temporal Super-Resolution Analysis of a Reference Signal Less Photoplethysmogram for Heart Rate Estimation During Physical Activity
    Pankaj
    Kumar, Ashish
    Kumar, Manjeet
    Komaragiri, Rama
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [9] A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
    Salehizadeh, Seyed M. A.
    Dao, Duy
    Bolkhovsky, Jeffrey
    Cho, Chae
    Mendelson, Yitzhak
    Chon, Ki H.
    SENSORS, 2016, 16 (01)
  • [10] A dynamic reconfigurable wearable device to acquire high quality PPG signal and robust heart rate estimate based on deep learning algorithm for smart healthcare system
    Ngoc-Thang, Bui
    Tien Nguyen, Thi My
    Truong, Trong Toai
    Nguyen, Bang Le-Huy
    Nguyen, Tuy Tan
    Biosensors and Bioelectronics: X, 2022, 12