Gamma-H2AX biodosimetry for use in large scale radiation incidents: comparison of a rapid '96 well lyse/fix' protocol with a routine method

被引:37
|
作者
Moquet, Jayne [1 ]
Barnard, Stephen [1 ]
Rothkamm, Kai [1 ]
机构
[1] Publ Hlth England, Ctr Radiat Chem & Environm Hazards, Didcot, Oxon, England
来源
PEERJ | 2014年 / 2卷
关键词
Gamma-H2AX foci; DNA double-strand break; Biological dosimetry; Ionising radiation; Triage; Blood sample processing; Finger prick; HUMAN-LYMPHOCYTES; DNA-DAMAGE; EXPOSURE; ASSAY; FOCI; REPAIR; TRIAGE;
D O I
10.7717/peerj.282
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Following a radiation incident, preliminary dose estimates made by gamma-H2AX foci analysis can supplement the early triage of casualties based on clinical symptoms. Sample processing time is important when many individuals need to be rapidly assessed. A protocol was therefore developed for high sample throughput that requires less than 0.1 ml blood, thus potentially enabling finger prick sampling. The technique combines red blood cell lysis and leukocyte fixation in one step on a 96 well plate, in contrast to the routine protocol, where lymphocytes in larger blood volumes are typically separated by Ficoll density gradient centrifugation with subsequent washing and fixation steps. The rapid '96 well lyse/fix' method reduced the estimated sample processing time for 96 samples to about 4 h compared to 15 h using the routine protocol. However, scoring 20 cells in 96 samples prepared by the rapid protocol took longer than for the routine method (3.1 versus 1.5 h at zero dose; 7.0 versus 6.1 h for irradiated samples). Similar foci yields were scored for both protocols and consistent dose estimates were obtained for samples exposed to 0, 0.2, 0.6, 1.1, 1.2, 2.1 and 4.3 Gy of 250 kVp X-rays at 0.5 Gy/min and incubated for 2 h. Linear regression coefficients were 0.87 +/- 0.06 (R-2 = 97.6%) and 0.85 +/- 0.05 (R-2 = 98.3%) for estimated versus actual doses for the routine and lyse/fix method, respectively. The lyse/fix protocol can therefore facilitate high throughput processing for gamma-H2AX biodosimetry for use in large scale radiation incidents, at the cost of somewhat longer foci scoring times.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 1 条
  • [1] Manual versus automated γ-H2AX foci analysis across five European laboratories: Can this assay be used for rapid biodosimetry in a large scale radiation accident?
    Rothkamm, Kai
    Barnard, Stephen
    Ainsbury, Elizabeth A.
    Al-hafidh, Jenna
    Barquinero, Joan-Francesc
    Lindholm, Carita
    Moquet, Jayne
    Perala, Marjo
    Roch-Lefevre, Sandrine
    Scherthan, Harry
    Thierens, Hubert
    Vral, Anne
    Vandersickel, Veerle
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2013, 756 (1-2) : 170 - 173