Use of MR exponential diffusion-weighted images to eradicate T2 "shine-through" effect

被引:95
|
作者
Provenzale, JM
Engelter, ST
Petrella, JR
Smith, JS
MacFall, JR
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
关键词
D O I
10.2214/ajr.172.2.9930819
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
[No abstract available]
引用
收藏
页码:537 / 539
页数:3
相关论文
共 50 条
  • [1] Hepatic hemangiomas: Factors associated with T2 shine-through effect on diffusion-weighted MR sequences
    Duran, Rafael
    Ronot, Maxime
    Kerbaol, Anne
    Van Beers, Bernard
    Vilgrain, Valerie
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (03) : 468 - 478
  • [2] Acute cerebral infarction: Quantification of spin-density and T2 shine-through phenomena on diffusion-weighted MR images
    Burdette, JH
    Elster, AD
    Ricci, PE
    RADIOLOGY, 1999, 212 (02) : 333 - 339
  • [3] Acute cerebral infarction: Quantification of spin-density and T2 "Shine-through" phenomena on diffusion-weighted MR images
    Burdette, JH
    Ricci, PE
    Elster, AD
    RADIOLOGY, 1998, 209P : 200 - 200
  • [4] Pitfalls of Diffusion-Weighted Imaging: Clinical Utility of T2 Shine-through and T2 Black-out for Musculoskeletal Diseases
    Kim, Yuri
    Lee, Seul Ki
    Kim, Jee-Young
    Kim, Jun-Ho
    DIAGNOSTICS, 2023, 13 (09)
  • [5] The value of b required to avoid T2 shine-through from old lacunar infarcts in diffusion-weighted imaging
    Geijer, B
    Sundgren, PC
    Lindgren, A
    Brockstedt, S
    Ståhlberg, F
    Holtås, S
    NEURORADIOLOGY, 2001, 43 (07) : 511 - 517
  • [6] The value of b required to avoid T2 shine-through from old lacunar infarcts in diffusion-weighted imaging
    B. Geijer
    P. C. Sundgren
    A. Lindgren
    S. Brockstedt
    F. Ståhlberg
    S. Holtås
    Neuroradiology, 2001, 43 : 511 - 517
  • [7] Removing Ambiguity Caused by T2 Shine-through using Weighted Diffusion Subtraction (WDS)
    Oshio, Koichi
    Okuda, Shigeo
    Shinmoto, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (01) : 146 - 148
  • [8] Apparent diffusion coefficient-dependent voxelwise computed diffusion-weighted imaging: An approach for improving SNR and reducing T2 shine-through effects
    Gatidis, Sergios
    Schmidt, Holger
    Martirosian, Petros
    Nikolaou, Konstantin
    Schwenzer, Nina F.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (04) : 824 - 832
  • [9] Synthetic DWI: contrast improvement for diffusion-weighted imaging in prostate using T1 shine-through by synthesizing images with adjusted TR and TE
    Ueda, Yu
    Tamada, Tsutomu
    Higaki, Atsushi
    Kido, Ayumu
    Sanai, Hiroyasu
    Moriya, Kazunori
    Takahara, Taro
    Obara, Makoto
    Van Cauteren, Marc
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2025,
  • [10] Spontaneous intracerebral hematoma on diffusion-weighted images:: Influence of T2-shine-through and T2-blackout effects
    Silvera, S
    Oppenheim, C
    Touzé, E
    Ducreux, D
    Page, P
    Domigo, V
    Mas, JL
    Roux, FX
    Fréy, D
    Meder, JF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (02) : 236 - 241