A structure measurement of the CCD pixel by using the X-ray beam

被引:3
|
作者
Tsunemi, H
Yoshita, K
Kitamoto, S
Miyata, E
机构
关键词
charge-coupled-device; gate structure; moire pattern; sub pixel resolution;
D O I
10.1117/12.278892
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
We report here the result of the structure measurement of a charge-coupled device (CCD) pixel with sub pixel resolution by using a new technique. The new technique makes use of a parallel X-ray beam and a metal mesh placed just in front of the CCD. The CCD camera we used in the first experiment, is a conventional system using the TC213 (Texas Instrument Japan (TIJ)) whose pixel size is 12 mu m x 12 mu m with one million pixels. The mesh has 4 mu m diameter holes spaced at 12 mu m intervals. We produced an efficiency map within a typical pixel showing the gate structure in detail. In the reconstruction process, we have to determine the mutual alignment between the CCD and the mesh in detail. The method we used can easily determine it with enough precision. By selecting single pixel events, me determined a pixel boundary. The distribution of two pixel split event can give us more information in the behavior of the primary charge cloud.
引用
收藏
页码:230 / 240
页数:11
相关论文
共 50 条
  • [1] X-ray measurement of the subpixel structure of the XMM EPIC MOS CCD
    Tsunemi, H
    Yoshita, K
    Short, AD
    Bennie, PJ
    Turner, MJL
    Abbey, AF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 437 (2-3): : 359 - 366
  • [2] The x-ray imaging system's requirements for CCD pixel
    Yu, Chunyu
    Kong, Lingli
    Zhang, Junju
    He, Chunjiu
    Zhang, Shengdong
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [3] X-ray polarimetry and position measurement using the photoeffect and diffusion in a CCD
    Schmidt, KH
    Buschhorn, G
    Kotthaus, R
    Rzepka, M
    Weinmann, PM
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 230 - 241
  • [4] X-ray CCD with charge injection structure
    Prigozhin, G
    Burke, B
    Bautz, M
    Kissel, S
    LaMarr, B
    Freytsis, M
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 357 - 365
  • [5] Measurement of X-ray beam emittance using crystal optics at an X-ray undulator beamline
    Kohmura, Y
    Suzuki, Y
    Awaji, M
    Tanaka, T
    Hara, T
    Goto, S
    Ishikawa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 452 (1-2): : 343 - 350
  • [6] X-ray polarimetry and position measurement using the photoeffect and charge diffusion in a CCD
    Schmidt, KH
    Bogner, M
    Buschhorn, G
    Kotthaus, R
    Oberhuber, R
    Rzepka, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3): : 215 - 219
  • [7] A multiple CCD X-ray detector and its first operation with synchrotron radiation X-ray beam
    Suzuki, M
    Yamamoto, M
    Kumasaka, T
    Sato, K
    Toyokawa, H
    Aries, IF
    Jerram, PA
    Ueki, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 174 - 181
  • [8] New techniques for the measurement of x-ray beam or x-ray optics quality
    Zeitoun, P
    Balcou, P
    Bucourt, S
    Benredjem, D
    Delmotte, F
    Dovillaire, G
    Douillet, D
    Dunn, J
    Faivre, G
    Fajardo, M
    Goldberg, KA
    Idir, M
    Hubert, S
    Hunter, JR
    Jacquemot, S
    Kazamias, S
    le Pape, S
    Levecq, X
    Lewis, CLS
    Marmoret, R
    Mercère, P
    Morlens, AS
    Naulleau, PP
    Rémond, C
    Rocca, JJ
    Sebban, S
    Smith, RF
    Ravet, MF
    Troussel, P
    Valentin, C
    Vanbostal, L
    SOFT X-RAY LASERS AND APPLICATIONS V, 2003, 5197 : 194 - 204
  • [9] Linac X-Ray Beam Spot Measurement Using MLC Or Jaws
    Cassese, M.
    Purwar, A.
    Star-Lack, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3088 - 3089
  • [10] Investigating chemical structure in a silicon CCD using extended X-ray absorption fine structure
    Keay, A
    Wells, A
    Owens, A
    McCarthy, KJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 124 (04): : 615 - 623