Development of digital image surface and its application to derived 12-lead ECG

被引:0
|
作者
Takahashi, Kunio [1 ]
Wei, Daming [1 ]
机构
[1] Univ Aizu, Grad Sch Comp Sci & Engn, Fukushima 9658580, Japan
关键词
D O I
10.1109/CIT.2007.115
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The "image surface" is a data collection of spatial vectors that reflect relationship between heart vector and measured electrocardiograms, supposing the heart source is a fixed dipole source. For long, the Frank image surface has been used. However, since the Frank model represents an average model of western population, it may not fit other populations like Japanese, and therefore may affect the accuracy of applications In this study, to improve the accuracy of the derived 12-lead ECG, we developed the digital image surface based on the personalized torso models constructed from MRI images. The boundary element method was used to calculate the values of digital image surface by applying electrical current dipole source on the torso-heart model. Further, the valises of the digital image surface for eight subjects were averaged as a representation of typical models of Japanese population. As an application, derived 12-lead ECG is obtained based on the digital image surface and the results is compared with those based on the Frank image surface. The results show that the digital image surface can get better accuracy than the Frank image surface.
引用
收藏
页码:1122 / 1126
页数:5
相关论文
共 50 条
  • [1] COMPARISON OF DIGITAL 12-LEAD ECG AND DIGITAL 12-LEAD HOLTER ECG RECORDINGS IN HEALTHY MALE SUBJECTS
    Taubel, J.
    Naseem, A.
    Shakeri-Nejad, K.
    Dingemanse, J.
    Ferber, G.
    Camm, A. J.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2011, 89 : S11 - S11
  • [2] Derived 12-lead ECG systems
    Nelwan, SP
    Meij, SH
    JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (01) : 29 - 30
  • [3] Prehospital 12-lead ECG
    Joyce, SM
    ANNALS OF EMERGENCY MEDICINE, 1997, 30 (03) : 352 - 352
  • [4] PREHOSPITAL 12-LEAD ECG
    WHITE, RD
    ANNALS OF EMERGENCY MEDICINE, 1992, 21 (05) : 586 - 586
  • [5] Sensitivity to noise and artifacts of the Mason-Likar 12-lead ECG and the EASI-derived 12-lead ECG for monitoring applications
    Thulin, A
    Pettersson, J
    Pahlm, O
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A76 - A76
  • [6] Image based deep learning in 12-lead ECG diagnosis
    Ao, Raymond
    He, George
    FRONTIERS IN ARTIFICIAL INTELLIGENCE, 2023, 5
  • [7] Accuracy of QT measurement in the EASI-derived 12-lead ECG
    Martinez, Juan Pablo
    Laguna, Pablo
    Olmos, Salvador
    Pahlm, Olle
    Petersson, Jonas
    Sornmo, Leif
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4192 - +
  • [8] The 12-lead ECG in peripartum cardiomyopathy
    Tibazarwa, Kemi
    Lee, Geraldine
    Mayosi, Bongani
    Carrington, Melinda
    Stewart, Simon
    Sliwa, Karen
    CARDIOVASCULAR JOURNAL OF AFRICA, 2012, 23 (06) : 322 - 329
  • [9] Prehospital 12-lead ECG - Reply
    Selker, HP
    Zalenski, RJ
    Aufderheide, TP
    ANNALS OF EMERGENCY MEDICINE, 1997, 30 (03) : 353 - 353
  • [10] Value of a derived 12-lead ECG for detecting transient myocardial ischemia
    Drew, BJ
    Adams, MG
    Wung, SF
    Dower, GE
    JOURNAL OF ELECTROCARDIOLOGY, 1995, 28 : 211 - 211