The C-2W experiment produces advanced beam-driven field reversed configuration (FRC) plasmas, which are sustained in steady state utilizing variable energy neutral beams (15-40 keV, total power up to 21 MW), advanced divertors, end bias electrodes, and an active plasma control system. Since heating, current drive, and refueling from neutral beam injection are essential to FRC sustainment, it is crucial to have accurate measurements of the beam power being injected into the plasma. A new tungsten wire calorimeter has been designed, built, calibrated on a test stand, and implemented to make the first direct measurements of the time-average injected beam power into C-2W. This paper outlines the design of the diagnostic, along with calibration methods and experimental results. Published under license by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] ESecondary electron emission detectors for neutral beam characterization on C-2W
    Titus, J. B.
    Magee, R. M.
    Isakov, I.
    Pirogov, K.
    Korepanov, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [2] Active fast ion charge exchange measurements using a neutral particle analyzer and multiple beam species in C-2W
    Kamio, S.
    Granstedt, E. M.
    Clary, R.
    Player, G.
    Korepanov, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (10):
  • [3] Secondary electron emission detectors for neutral beam characterization on C-2W (89, 10I123, 2018)
    Titus, J. B.
    Magee, R. M.
    Isakov, I.
    Pirogov, K.
    Korepanov, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):
  • [4] ULTRASONIC CALORIMETER FOR BEAM POWER MEASUREMENTS
    ZAPF, TL
    HARVEY, ME
    LARSEN, NT
    STOLTENBERG, RE
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1977, 24 (02): : 139 - 139
  • [5] WIRE CALORIMETER FOR ABSOLUTE AND ACCURATE LASER-POWER MEASUREMENTS
    NOWICKI, R
    ELECTRONICS LETTERS, 1968, 4 (19) : 404 - &
  • [6] A novel technique for in situ calibration of the C-2W electromagnetic neutral particle analyzer utilizing machine learning
    Player, G.
    Clary, R.
    Dettrick, S.
    Korepanov, S.
    Magee, R. M.
    Tajima, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [7] Helium line ratio imaging in the C-2W divertor
    Granstedt, E. M.
    Osin, D.
    Gupta, D.
    Kinley, J.
    Knapp, K.
    Munoz-Burgos, J. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (11):
  • [8] Automated signal classification in the C-2W fusion experiment
    Bolte, Nathan
    Allfrey, Ian
    Mendoza, Roberto
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [9] Comprehensive imaging of C-2W plasmas: Instruments and applications
    Granstedt, E. M.
    Gupta, D.
    Sweeney, J.
    Tobin, M.
    Dikovsky, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (04):
  • [10] Jet outflow and open field line measurements on the C-2W advanced beam-driven field-reversed configuration plasma experiment
    Sheftman, D.
    Schmitz, L.
    Gupta, D.
    Thompson, M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):