MUSCLE FORCE MEASUREMENT SYSTEM FOR LONG-TERM MONITORING DURING DISTRACTION OSTEOGENESIS

被引:0
|
作者
Jaw, Fu-Shan [1 ]
Hung, Chien-Ya
Lin, Chia-Ming
Lu, Pen-Li
Tseng, Yi-Li
Wang, Jyh-Horng [2 ]
机构
[1] Natl Taiwan Univ, Inst Biomed Engn, Coll Engn, Taipei 106, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Orthoped Surg, Taipei 100, Taiwan
关键词
circuit design; distraction osteogenesis; force measurement system; STRAIN-GAUGE; BONE; MODEL; COMPLICATIONS; RABBITS; LATENCY;
D O I
10.1080/10739149.2011.623207
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Distraction osteogenesis is a procedure in orthopedics for skeletal lengthening. This operation sometimes causes clinical complications such as paralysis and pain related to the rate and extent of distraction. Therefore, a tension-force monitoring system is mandatory to control optimal lengthening. We developed a portable, low-power consumption system to continuously monitor the distracted tensions during the distraction osteogenesis period on the tibias of four male New Zealand white rabbits. The lengthening rate was 1 mm per day at frequencies of once a day in one rabbit, and of three successive steps in the others. The system indicates the distraction measured by force, which is considered to be more physiological in nature rather than by distance. Radiographs were also taken for comparison. The results showed that the system was stable and approximate to being ideal. The measured distract-tension recovered to a steady state faster at the frequency of 1 mm a day in three steps, rather than once per day. During the duration of the entire operation, each single lengthening induced more extensive force than that of one-day totals. The integer tension gradually increased until 15 days and tended to be stable. The radiographic examinations also revealed that the tibias healed well after the lengthening; consequently, a dispensable X-ray might be mostly replaced by the system monitoring. This system might be helpful to monitor force measurement for the improvement of distraction osteogenesis.
引用
收藏
页码:475 / 485
页数:11
相关论文
共 50 条
  • [1] Portable system for force measurement of long-term monitoring during human gait
    Sehnen, Romulo
    Balbinot, Amanda
    Balbinot, Alexandre
    PROCEEDINGS IWBBIO 2013: INTERNATIONAL WORK-CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, 2013, : 215 - 222
  • [2] Long-Term Effects of Distraction Osteogenesis of the Mandible
    Peacock, Zachary S.
    Salcines, Alfonso
    Troulis, Maria J.
    Kaban, Leonard B.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (07) : 1512 - 1523
  • [3] Long-term results of distraction osteogenesis of the maxilla and midface
    Wiltfang, J
    Hirschfelder, U
    Neukam, FW
    Kessler, P
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2002, 40 (06): : 473 - 479
  • [4] Frontofacial Advancement by Distraction Osteogenesis: A Long-Term Review
    Gwanmesia, Ivo
    Jeelani, Owase
    Hayward, Richard
    Dunaway, David
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 135 (02) : 553 - 560
  • [5] Long-term stability after craniofacial distraction osteogenesis
    Al-Daghreer, Saleh
    Flores-Mir, Carlos
    El-Bialy, Tarek
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (09) : 1812 - 1819
  • [6] EXPERIMENTAL MANDIBULAR REGROWTH BY DISTRACTION OSTEOGENESIS - LONG-TERM RESULTS
    COSTANTINO, PD
    FRIEDMAN, CD
    SHINDO, ML
    HOUSTON, G
    SISSON, GA
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1993, 119 (05) : 511 - 516
  • [7] Comprehensive Long-Term Outcomes Following Mandibular Distraction Osteogenesis
    Kosyk, Mychajlo S.
    Salinero, Lauren K.
    Morales, Carrie Z.
    Shakir, Sameer
    Cielo, Christopher M.
    Scott, Michelle
    Nah, Hyun-Duck
    Bartlett, Scott P.
    Taylor, Jesse A.
    Swanson, Jordan W.
    CLEFT PALATE CRANIOFACIAL JOURNAL, 2025, 62 (01): : 108 - 116
  • [8] Lengthening of muscle during distraction osteogenesis
    De Deyne, PG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (403) : S171 - S177
  • [9] Horizontal alveolar distraction osteogenesis for dental implant: long-term results
    Yamauchi, Kensuke
    Takahashi, Tetsu
    Nogami, Shinnosuke
    Kataoka, Yoshihiro
    Miyamoto, Ikuya
    Funaki, Katsuyuki
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (05) : 563 - 568
  • [10] Long-term evaluation of the stability of reconstructed condyles by transport distraction osteogenesis
    Xiao, E.
    Zhang, Y.
    An, J.
    Li, J.
    Yan, Y.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (12) : 1490 - 1494