Biomechanical comparison of fully and partially threaded screws for fixation of slipped capital femoral epiphysis

被引:22
|
作者
Miyanji, Firoz [2 ]
Mahar, Andrew [1 ,2 ]
Oka, Richard [2 ]
Pring, Maya [2 ]
Wenger, Dennis [1 ,2 ]
机构
[1] San Diego State Univ, Dept Orthoped Surg, San Diego, CA 92182 USA
[2] Rady Childrens Hosp, Dept Orthoped, San Diego, CA 92182 USA
关键词
slipped capital femoral epiphysis; fully threaded screw; biomechanical stability;
D O I
10.1097/bpo.0b013e31815a5fa4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Previous data have shown that an equal number of threads on each side of the physis maximizes stability for slipped capital femoral epiphysis (SCFE) fixation. The purpose of the current study was to determine if a fully threaded cancellous screw provides greater stability compared with a partially threaded screw in a porcine model. Methods: Twenty skeletally immature porcine femurs were sectioned, and a 30-degree angular wedge was resected from the femoral neck to simulate SCFE. Femora were randomly assigned to partially threaded (16 mm) or fully threaded screw groups (n = 10/group). Kirschner wires were inserted in a retrograde fashion to stabilize the proximal fragment. Each 7.3-mm-diameter screw was placed using fluoroscopic guidance to obtain 3 threads crossing the physis. Specimens were fixed in custom fixation rigs, and the epiphyseal fragment was loaded at 0.5 mm/s in a posterior-inferior direction to simulate slip progression. Data for displacement (in millimeters) and force (in newtons) were collected for the entire test. Forces at 2, 4, 6, and 8 turn of fragment displacement were compared between groups using a 1-way analysis of variance (p < 0.05). Results: Increasing epiphyseal displacements were associated with incremental increases in loading. There were no significant differences between fully threaded or partially threaded screws for loads at each displacement. Each stepwise increase in displacement was associated with approximately 325 N of force. Conclusion: There was no biomechanical benefit when using a fully threaded screw for stabilization of an in vitro SUE model. Clinical Relevance: Although there were no differences between screw types in an in vitro model, bone healing around the fully threaded screw may eventually provide greater stability. The use of fully threaded screw remains a reasonable option in the treatment of SCFE, and implant removal may be easier with such a system. Further studies are warranted to verify these 2 points.
引用
收藏
页码:49 / 52
页数:4
相关论文
共 50 条
  • [1] Biomechanical testing of bioabsorbable cannulated screws for slipped capital femoral epiphysis fixation
    Kroeber, MW
    Rovinsky, D
    Haskell, A
    Heilmann, M
    Lotz, J
    Otsuka, N
    ORTHOPEDICS, 2002, 25 (06) : 659 - 663
  • [3] FIXATION OF SLIPPED CAPITAL FEMORAL EPIPHYSIS WITH AO-SCREWS
    HYBBINETTE, CH
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (04): : 476 - 477
  • [4] Evaluation of biomechanical properties of bioabsorbable cannulated screws for surgical fixation in cases of slipped capital femoral epiphysis
    Kröber, MW
    Rovinsky, D
    Lotz, J
    Carstens, C
    ORTHOPADE, 2002, 31 (06): : 563 - +
  • [5] Biomechanical considerations in slipped capital femoral epiphysis and insights into prophylactic fixation
    Leblanc, E.
    Bellemore, J. M.
    Cheng, T.
    Little, D. G.
    Birke, O.
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2017, 11 (02) : 120 - 127
  • [6] Single screw fixation for slipped capital femoral epiphysis: A biomechanical analysis of cannulated screws of varying outer diameter
    Fehnel, DJ
    Aronsson, DD
    Stone, A
    PEDIATRICS, 1997, 100 (03) : 483 - 483
  • [7] Biomechanical Comparison of Perpendicular Versus Oblique In Situ Screw Fixation of Slipped Capital Femoral Epiphysis
    Merz, Michael K.
    Amirouche, Farid
    Solitro, Giovanni F.
    Silverstein, Jeffrey A.
    Surma, Tyler
    Gourineni, Prasad V.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2015, 35 (08) : 816 - 820
  • [8] Percutaneous in situ fixation of slipped capital femoral epiphysis using two threaded Steinmann pins
    Nonweiler, B
    Hoffer, M
    Weinert, C
    Rosenfeld, S
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1996, 16 (01) : 56 - 60
  • [9] Is there a persistent capital femoral epiphysis growth after screw fixation for slipped capital femoral epiphysis?
    Sleth, Camille
    Bauzou, Francois
    De Cristo, Claudia
    Alkar, Fanny
    Joly-Monrigal, Pauline
    Jeandel, Clement
    Cottalorda, Jerome
    M'Sabah, Djamel Louahem
    Delpont, Marion
    JOURNAL OF HIP PRESERVATION SURGERY, 2022, 9 (02): : 90 - 94
  • [10] PERCUTANEOUS IN SITU FIXATION OF SLIPPED CAPITAL FEMORAL EPIPHYSIS
    Chlebeck, Jesse D.
    Birch, Christopher E.
    Lisle, Jennifer W.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2016, 6 (01):