Baseline correction of a correlation model for improving the prediction accuracy of infrared marker-based dynamic tumor tracking

被引:8
|
作者
Akimoto, Mami [1 ]
Nakamura, Mitsuhiro [1 ]
Mukumoto, Nobutaka [1 ]
Yamada, Masahiro [1 ]
Tanabe, Hiroaki [2 ]
Ueki, Nami [1 ]
Kaneko, Shuji [1 ]
Matsuo, Yukinori [1 ]
Mizowaki, Takashi [1 ]
Kokubo, Masaki [2 ,3 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto 6068507, Japan
[2] Inst Biomed Res & Innovat, Div Radiat Oncol, Kobe, Hyogo, Japan
[3] Kobe City Med Ctr Gen Hosp, Div Radiat Oncol, Kobe, Hyogo, Japan
来源
基金
日本科学技术振兴机构;
关键词
Vero4DRT; IR Tracking; correlation model; baseline drift; GUIDED RADIOTHERAPY SYSTEM; RESPIRATORY MOTION; RADIATION-THERAPY; IRRADIATION; MANAGEMENT;
D O I
10.1120/jacmp.v16i2.4896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We previously found that the baseline drift of external and internal respiratory motion reduced the prediction accuracy of infrared (IR) marker-based dynamic tumor tracking irradiation (IR Tracking) using the Vero4DRT system. Here, we proposed a baseline correction method, applied immediately before beam delivery, to improve the prediction accuracy of IR Tracking. To perform IR Tracking, a four-dimensional (4D) model was constructed at the beginning of treatment to correlate the internal and external respiratory signals, and the model was expressed using a quadratic function involving the IR marker position (x) and its velocity (v), namely function F(x,v). First, the first 4D model, F-1st(x,v), was adjusted by the baseline drift of IR markers (BDIR) along the x-axis, as function F'(x,v). Next, BDdetect, that defined as the difference between the target positions indicated by the implanted fiducial markers (P-detect) and the predicted target positions with F'(x,v) (P-predict) was determined using orthogonal kV X-ray images at the peaks of the P-detect of the end-inhale and end-exhale phases for 10 s just before irradiation. F'(x,v) was corrected with BDdetect to compensate for the residual error. The final corrected 4D model was expressed as F-cor(x,v) = F-1st{(x-BDIR), v}-BDdetect. We retrospectively applied this function to 53 paired log files of the 4D model for 12 lung cancer patients who underwent IR Tracking. The 95th percentile of the absolute differences between P-detect and P-predict (vertical bar E-p vertical bar) was compared between F-1st(x,v) and F-cor(x,v). The median 95th percentile of vertical bar E-p vertical bar (units: mm) was 1.0, 1.7, and 3.5 for F-1st(x,v), and 0.6, 1.1, and 2.1 for F-cor(x,v) in the left-right, anterior-posterior, and superior-inferior directions, respectively. Over all treatment sessions, the 95th percentile of vertical bar E-p vertical bar peaked at 3.2 mm using F-cor(x,v) compared with 8.4 mm using F-1st(x,v). Our proposed method improved the prediction accuracy of IR Tracking by correcting the baseline drift immediately before irradiation.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 50 条
  • [1] Baseline Correction of a Correlation Model in Infrared Marker-Based Dynamic Tumor Tracking With A Gimbaled Linac
    Akimoto, M.
    Nakamura, M.
    Mukumoto, N.
    Yamada, M.
    Yokota, K.
    Tanabe, H.
    Ueki, N.
    Kaneko, S.
    Matsuo, Y.
    Monzen, H.
    Mizowaki, T.
    Kokubo, M.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S826 - S827
  • [2] Improving the Target Estimation Accuracy in Infrared Marker-Based Dynamic Tumor Tracking With a Gimbaled Linac
    Nakamura, M.
    Takamiya, M.
    Akimoto, M.
    Mukumoto, N.
    Yamada, M.
    Tanabe, H.
    Matsuo, Y.
    Mizowaki, T.
    Kokubo, M.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S825 - S826
  • [3] Influence of the correlation modeling period on the prediction accuracy of infrared marker-based dynamic tumor tracking using a gimbaled X-ray head
    Nakamura, Mitsuhiro
    Akimoto, Mami
    Mukumoto, Nobutaka
    Yamada, Masahiro
    Tanabe, Hiroaki
    Ueki, Nami
    Matsuo, Yukinori
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (03): : 204 - 209
  • [4] Intrafractional tracking accuracy in infrared marker-based hybrid dynamic tumour-tracking irradiation with a gimballed linac
    Mukumoto, Nobutaka
    Nakamura, Mitsuhiro
    Yamada, Masahiro
    Takahashi, Kunio
    Tanabe, Hiroaki
    Yano, Shinsuke
    Miyabe, Yuki
    Ueki, Nami
    Kaneko, Shuji
    Matsuo, Yukinori
    Mizowaki, Takashi
    Sawada, Akira
    Kokubo, Masaki
    Hiraoka, Masahiro
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 (02) : 301 - 305
  • [5] THE FAST METHOD FOR CORRECTION OF DISTORTION ON INFRARED MARKER-BASED TRACKING SYSTEM
    Wang, Haibin
    He, Qing
    Guan, Guan
    Leng, Bin
    Zeng, Dewen
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2013, 6 (01) : 259 - 277
  • [6] Predictive uncertainty in infrared marker-based dynamic tumor tracking with Vero4DRT
    Akimoto, Mami
    Nakamura, Mitsuhiro
    Mukumoto, Nobutaka
    Tanabe, Hiroaki
    Yamada, Masahiro
    Matsuo, Yukinori
    Monzen, Hajime
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2013, 40 (09)
  • [7] Predicting accuracy in pose estimation for marker-based tracking
    Davis, L
    Clarkson, E
    Rolland, JP
    SECOND IEEE AND ACM INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY, PROCEEDINGS, 2003, : 28 - 35
  • [8] Optimization of Marker-Based VMAT Plans for Lung Tumor Tracking
    Omotayo, A.
    Venkataraman, S.
    McCurdy, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E329 - E329
  • [9] Ghost Marker Prediction, Detection and Elimination in Marker-Based Optical Tracking Systems
    Yan, G.
    Li, J.
    Mittauer, K.
    Huang, Y.
    Lu, B.
    Liu, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 194 - 194
  • [10] Constrained optimization towards marker-based tumor tracking in VMAT
    Omotayo, Azeez
    Venkataraman, Sankar
    McCurdy, Boyd
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (01):